13 resultados para appraisal

em Indian Institute of Science - Bangalore - Índia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We examine the exclusion limits set by the CDF and D0 experiments on the Standard Model Higgs boson mass from their searches at the Tevatron in the light of large theoretical uncertainties on the signal and background cross sections. We show that when these uncertainties are consistently taken into account, the sensitivity of the experiments becomes significantly lower and the currently excluded mass range M-H = 158-175 GeV could be entirely reopened. The necessary luminosity required to recover the current sensitivity is found to be a factor of two higher than the present one. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Road transportation, as an important requirement of modern society, is presently hindered by restrictions in emission legislations as well as the availability of petroleum fuels, and as a consequence, the fuel cost. For nearly 270 years, we burned our fossil cache and have come to within a generation of exhausting the liquid part of it. Besides, to reduce the greenhouse gases, and to obey the environmental laws of most countries, it would be necessary to replace a significant number of the petroleum-fueled internal-combustion-engine vehicles (ICEVs) with electric cars in the near future. In this article, we briefly describe the merits and demerits of various proposed electrochemical systems for electric cars, namely the storage batteries, fuel cells and electrochemical supercapacitors, and determine the power and energy requirements of a modern car. We conclude that a viable electric car could be operated with a 50 kW polymer-electrolyte fuel cell stack to provide power for cruising and climbing, coupled in parallel with a 30 kW supercapacitor and/or battery bank to deliver additional short-term burst-power during acceleration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The stability of slopes is a major problem in geotechnical engineering. Of the methods available for the analysis of soil slopes such as limit equilibrium methods, limit analysis and numerical methods such as FEM and FDM, limit equilibrium methods are popular and generally used, owing to their simplicity in formulation and in evaluating the overall factor of safety of slope. However limit equilibrium methods possess certain disadvantages. They do not consider whether the slope is an embankment or natural slope or an excavation and ignore the effect of incremental construction, initial stress, stress strain behavior etc. In the work reported in this paper, a comparative study of actual state of stress and actual factor of safety and Bishop's factor of safety is performed. The actual factor of safety is obtained by consideration of contours of mobilised shear strains. Using Bishop's method of slices, the critical slip surfaces of a number of soil slopes with different geometries are determined and both the factors of safety are obtained. The actual normal stresses and shear stresses are determined from finite difference formulation using FLAG (Fast Lagrangian Analysis of Continuaa) with Mohr-Coulomb model. The comparative study is performed in terms of parameter lambda(c phi) (= gamma H tan phi/c). I is shown that actual factor of safety is higher than Bishop's factor of safety depending on slope angle and lambda(c phi).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two of the aims of laboratory one-dimensional consolidation tests are prediction of the end of primary settlement, and determination of the coefficient of consolidation of soils required for the time rate of consolidation analysis from time-compression data. Of the many methods documented in the literature to achieve these aims, Asaoka's method is a simple and useful tool, and yet the most neglected one since its inception in the geotechnical engineering literature more than three decades ago. This paper appraises Asaoka's method, originally proposed for the field prediction of ultimate settlement, from the perspective of laboratory consolidation analysis along with recent developments. It is shown through experimental illustrations that Asaoka's method is simpler than the conventional and popular methods, and makes a satisfactory prediction of both the end of primary compression and the coefficient of consolidation from laboratory one-dimensional consolidation test data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article is aimed to delineate groundwater sources in Holocene deposits area in the Gulf of Mannar Coast from Southern India. For this purpose 2-D electrical resistivity tomography (ERT), hydrochemical and granulomerical studies were carried out and integrated to identify hydrogeological structures and portable groundwater resource in shallow depths which in general appears in the coastal tracts. The 2-D ERT was used to determine the two-dimensional subsurface geological formations by multicore cable with Wenner array. Low resistivity of 1-5 Omega m for saline water appeared due to calcite at the depth of about 5 m below the ground level (bgl). Sea water intrusion was observed around the maximum resistivity as 5 Omega m at the 8 m depth, bgl in the calcite environs, but the calcareous sandstone layer shows around 15-64 Omega m at the 6 m depth, bgl. The hydrochemical variation of TDS, HCO3-, Cl-, Na+, K+, Ca2+, and Mg2+ concentrations was observed for the saline and sea water intrusion in the groundwater system. The granulometic analysis shows that the study area was under the sea between 5400 and 3000 year ago. The events of ice melting an unnatural ice-stone rain/hail among 5000-4000 years ago resulted in the inundation of sea over the area and deposits of late Holocene marine transgression formation up to Puthukottai quartzite region for a stretch of around 17 km.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The peaking of most oil reserves and impending climate change are critically driving the adoption of solar photovoltaic's (PV) as a sustainable renewable and eco-friendly alternative. Ongoing material research has yet to find a breakthrough in significantly raising the conversion efficiency of commercial PV modules. The installation of PV systems for optimum yield is primarily dictated by its geographic location (latitude and available solar insolation) and installation design (tilt, orientation and altitude) to maximize solar exposure. However, once these parameters have been addressed appropriately, there are other depending factors that arise in determining the system performance (efficiency and output). Dust is the lesser acknowledged factor that significantly influences the performance of the PV installations. This paper provides an appraisal on the current status of research in studying the impact of dust on PV system performance and identifies challenges to further pertinent research. A framework to understand the various factors that govern the settling/assimilation of dust and likely mitigation measures have been discussed in this paper. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The paper describes an experimental study of the normal and scratch hardnesses of a poly(methylmethacrylate). The deformations have been introduced using hard steel cones of a range of included cone angles. The influence of the state of interfacial lubrication is examined and rationalized. The observed time dependence of the two types of computed hardness data is compared and the nature of the correlations between these data is evaluated. It is observed that when the imposed strains are modest, say less than 0.2, the scratch hardness and normal hardness deformations produce self consistent data using first order and rather indiscriminate analyses for both types of deformations. At higher levels of imposed strain, a more critical appraisal of the nature of the deformation produced in the two cases is necessary in order to provide mutually consistent hardness values and hence unequivocal rheological characteristics for this polymer.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Certain parts of the State of Nagaland situated in the northeastern region of India have been experiencing rainfall deficit over the past few years leading to severe drought-like conditions, which is likely to be aggravated under a climate change scenario. The state has already incurred considerable losses in the agricultural sector. Regional vulnerability assessments need to be carried out in order to help policy makers and planners formulate and implement effective drought management strategies. The present study uses an 'index-based approach' to quantify the climate variability-induced vulnerability of farmers in five villages of Dimapur district, Nagaland. Indicators, which are reflective of the exposure, sensitivity and adaptive capacity of the farmers to drought, were quantified on the basis of primary data generated through household surveys and participatory rural appraisal supplemented by secondary data in order to calculate a composite vulnerability index. The composite vulnerability index of village New Showba was found to be the least, while Zutovi, the highest. The overall results reveal that biophysical characteristics contribute the most to overall vulnerability. Some potential adaptation strategies were also identified based on observations and discussions with the villagers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Building integrated photovoltaic (BIPV) applications are gaining widespread popularity. The performance of any given BIPV system is dependent on prevalent meteorological factors, site conditions and system characteristics. Investigations pertaining to the performance assessment of photovoltaic (PV) systems are generally confined to either controlled environment-chambers or computer-based simulation studies. Such investigations fall short of providing a realistic insight into how a PV system actually performs real-time. Solar radiation and the PV cell temperature are amongst the most crucial parameters affecting PV output. The current paper deals with the real-time performance assessment of a recently commissioned 5.25 kW, BIPV system installed at the Center for Sustainable Technologies, Indian Institute of Science, Bangalore. The overall average system efficiency was found to be 6% for the period May 2011-April 2012. This paper provides a critical appraisal of PV system performance based on ground realities, particularly characteristic to tropical (moderate) regions such as Bangalore, India. (C) 2013 International Energy Initiative. Published by Elsevier Inc. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Vernacular dwellings are well-suited climate-responsive designs that adopt local materials and skills to support comfortable indoor environments in response to local climatic conditions. These naturally-ventilated passive dwellings have enabled civilizations to sustain even in extreme climatic conditions. The design and physiological resilience of the inhabitants have coevolved to be attuned to local climatic and environmental conditions. Such adaptations have perplexed modern theories in human thermal-comfort that have evolved in the era of electricity and air-conditioned buildings. Vernacular local building elements like rubble walls and mud roofs are given way to burnt brick walls and reinforced cement concrete tin roofs. Over 60% of Indian population is rural, and implications of such transitions on thermal comfort and energy in buildings are crucial to understand. Types of energy use associated with a buildings life cycle include its embodied energy, operational and maintenance energy, demolition and disposal energy. Embodied Energy (EE) represents total energy consumption for construction of building, i.e., embodied energy of building materials, material transportation energy and building construction energy. Embodied energy of building materials forms major contribution to embodied energy in buildings. Operational energy (OE) in buildings mainly contributed by space conditioning and lighting requirements, depends on the climatic conditions of the region and comfort requirements of the building occupants. Less energy intensive natural materials are used for traditional buildings and the EE of traditional buildings is low. Transition in use of materials causes significant impact on embodied energy of vernacular dwellings. Use of manufactured, energy intensive materials like brick, cement, steel, glass etc. contributes to high embodied energy in these dwellings. This paper studies the increase in EE of the dwelling attributed to change in wall materials. Climatic location significantly influences operational energy in dwellings. Buildings located in regions experiencing extreme climatic conditions would require more operational energy to satisfy the heating and cooling energy demands throughout the year. Traditional buildings adopt passive techniques or non-mechanical methods for space conditioning to overcome the vagaries of extreme climatic variations and hence less operational energy. This study assesses operational energy in traditional dwelling with regard to change in wall material and climatic location. OE in the dwellings has been assessed for hot-dry, warm humid and moderate climatic zones. Choice of thermal comfort models is yet another factor which greatly influences operational energy assessment in buildings. The paper adopts two popular thermal-comfort models, viz., ASHRAE comfort standards and TSI by Sharma and Ali to investigate thermal comfort aspects and impact of these comfort models on OE assessment in traditional dwellings. A naturally ventilated vernacular dwelling in Sugganahalli, a village close to Bangalore (India), set in warm - humid climate is considered for present investigations on impact of transition in building materials, change in climatic location and choice of thermal comfort models on energy in buildings. The study includes a rigorous real time monitoring of the thermal performance of the dwelling. Dynamic simulation models validated by measured data have also been adopted to determine the impact of the transition from vernacular to modern material-configurations. Results of the study and appraisal for appropriate thermal comfort standards for computing operational energy has been presented and discussed in this paper. (c) 2014 K.I. Praseeda. Published by Elsevier Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The central problem in the study of glass-forming liquids and other glassy systems is the understanding of the complex structural relaxation and rapid growth of relaxation times seen on approaching the glass transition. A central conceptual question is whether one can identify one or more growing length scale(s) associated with this behavior. Given the diversity of molecular glass-formers and a vast body of experimental, computational and theoretical work addressing glassy behavior, a number of ideas and observations pertaining to growing length scales have been presented over the past few decades, but there is as yet no consensus view on this question. In this review, we will summarize the salient results and the state of our understanding of length scales associated with dynamical slow down. After a review of slow dynamics and the glass transition, pertinent theories of the glass transition will be summarized and a survey of ideas relating to length scales in glassy systems will be presented. A number of studies have focused on the emergence of preferred packing arrangements and discussed their role in glassy dynamics. More recently, a central object of attention has been the study of spatially correlated, heterogeneous dynamics and the associated length scale, studied in computer simulations and theoretical analysis such as inhomogeneous mode coupling theory. A number of static length scales have been proposed and studied recently, such as the mosaic length scale discussed in the random first-order transition theory and the related point-to-set correlation length. We will discuss these, elaborating on key results, along with a critical appraisal of the state of the art. Finally we will discuss length scales in driven soft matter, granular fluids and amorphous solids, and give a brief description of length scales in aging systems. Possible relations of these length scales with those in glass-forming liquids will be discussed.