5 resultados para Street cleaning

em Indian Institute of Science - Bangalore - Índia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a novel way of generating high voltage for electric discharge plasma in controlling NOx emission in diesel engine exhaust. A solar powered high frequency electric discharge topology has been suggested that will improve the size and specific energy density required when compared to the traditional repetitive pulse or 50 Hz AC energization. This methodology has been designed, fabricated and experimentally verified by conducting studies on real diesel engine exhaust.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conventionally, street entrepreneurs were either seen as a residue from a pre-modern era that is gradually disappearing (modernisation theory), or an endeavour into which marginalised populations are driven out of necessity in the absence of alternative ways of securing a livelihood (structuralist theory). In recent years, however, participa-tioninstreetentrepreneurshiphas beenre-read eitherasa rationaleconomicchoice(neo-liberal theory) or as conducted for cultural reasons (post-modern theory). The aim of this paper is to evaluate critically these competing explanations for participation in street entrepreneurship. To do this, face-to-face interviews were conducted with 871 street entrepreneurs in the Indian city of Bangalore during 2010 concerning their reasons for participation in street entrepreneurship. The finding is that no one explanation suffices. Some 12 % explain their participation in street entrepreneurship as necessity-driven, 15 % as traditional ancestral activity, 56 % as a rational economic choice and 17 % as pursued for social or lifestyle reasons. The outcome is a call to combine these previously rival explanations in order to develop a richer and more nuanced theorisation of the multifarious motives for street entrepreneurship in emerging market economies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There are multiple goals of a technology transfer office (TTO) based in a university system. Whilst commercialization is a critical goal, maintenance and cleaning of the TTO's database needs detailing. Literature in the area is scarce and only some researchers make reference to TTO data cleaning. During an attempt to understand the commercial strategy of a university TTO in Bangalore the challenge of data cleaning was encountered. This paper describes a case study of data cleaning at an Indian university based TTO. 382 patent records were analyzed in the study. The case study first describes the back ground of the university system. Second, the method to clean the data and the experiences encountered are highlighted. Insights drawn indicate that patent data cleaning in a TTO is a specialized area which needs attention. Overlooking this activity can have legal implications and may result in an inability to commercialize the patent. Two levels of patent data cleaning are discussed in this case study. Best practices of data cleaning in academic TTOs are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Experiments were conducted at laboratory level to treat the oxides of nitrogen (NOx) present in raw and dry biodiesel exhaust utilizing a combination of electric discharge plasma and bauxite residue, i. e., red mud, an industrial waste byproduct from the aluminum industry. In this paper, the adsorption and a possible catalytic property of bauxite residue are discussed. Nonthermal plasma was generated using dielectric barrier discharges initiated by ac/repetitive pulse energization. The effect of corona electrodes on the plasma generation was qualitatively studied through NOx cleaning. The plasma reactor and adsorbent reactors were connected in cascade while treating the exhaust. The diesel generator, running on biodiesel fuel, was electrically loaded to study the effectiveness of the cascade system in cleaning the exhaust. Interestingly, under the laboratory conditions studied, plasma-bauxite residue combination has shown good synergistic properties and enhanced the NOx removal up to about 90%. With proper scaling up, the suggested cascade system may become an economically feasible option to treat the exhaust in larger installations. The results were discussed emphasizing the role of bauxite residue as an adsorbent and as a room temperature catalyst.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Studies were carried out to estimate the power input to Dielectric Barrier Discharge (DBD) reactors powered by AC high voltage in the context of their application in non-thermal plasma cleaning of exhaust gases. Power input to the reactors was determined both theoretically and experimentally. Four different reactor geometries energized with 50 Hz and 1.5 kHz AC excitation were considered for the study. The theoretically estimated power using Manley's equation was found to agree with the experimental results. Results show that the analytically computed capacitance, without including the electrode edge effects, gives sufficiently good results that are matching with the measured values. For complex geometries where analytical calculation of capacitance is often difficult, a novel method of estimating the reactor capacitance, and hence the power input to the reactor, was introduced in this paper. The predicted results were validated with experiments.