62 resultados para SENSORY DRIVE
em Indian Institute of Science - Bangalore - Índia
Resumo:
Current source inverter (CSI) is an attractive solution in high-power drives. The conventional gate turn-off thyristor (GTO) based CSI-fed induction motor drives suffer from drawbacks such as low-frequency torque pulsation, harmonic heating, and unstable operation at low-speed ranges. These drawbacks can be overcome by connecting a current-controlled voltage source inverter (VSI) across the motor terminal replacing the bulky ac capacitors. The VSI provides the harmonic currents, which results in sinusoidal motor voltage and current even with the CSI switching at fundamental frequency. This paper proposes a CSI-fed induction motor drive scheme where GTOs are replaced by thyristors in the CSI without any external circuit to assist the turning off of the thyristors. Here, the current-controlled VSI, connected in shunt, is designed to supply the volt ampere reactive requirement of the induction motor, and the CSI is made to operate in leading power factor mode such that the thyristors in the CSI are autosequentially turned off. The resulting drive will be able to feed medium-voltage, high-power induction motors directly. A sensorless vector-controlled CSI drive based on the proposed configuration is developed. The experimental results from a 5 hp prototype are presented. Experimental results show that the proposed drive has stable operation throughout the operating range of speeds.
Resumo:
This paper develops a seven-level inverter structure for open-end winding induction motor drives. The inverter supply is realized by cascading four two-level and two three-level neutral-point-clamped inverters. The inverter control is designed in such a way that the common-mode voltage (CMV) is eliminated. DC-link capacitor voltage balancing is also achieved by using only the switching-state redundancies. The proposed power circuit structure is modular and therefore suitable for fault-tolerant applications. By appropriately isolating some of the inverters, the drive can be operated during fault conditions in a five-level or a three-level inverter mode, with preserved CMV elimination and DC-link capacitor voltage balancing, within a reduced modulation range.
Resumo:
This paper describes a method of adjusting the stator power factor angle for the control of an induction motor fed from a current source inverter (CSI) based on the concept of space vectors (or park vectors). It is shown that under steady state, if the torque angle is kept constant over the entire operating range, it has the advantage of keeping the slip frequency constant. This can be utilized to dispose of the speed feedback and simplify the control scheme for the drive, such that the stator voltage integral zero crossings alone can be used as a feedback for deciding the triggering instants of the CSI thyristors under stable operation of the system. A closed-loop control strategy is developed for the drive based on this principle, using a microprocessor-based control system and is implemented on a laboratory prototype CSI fed induction motor drive.
Resumo:
Common mode voltage (CMV) variations in PWM inverter-fed drives generate unwanted shaft and bearing current resulting in early motor failure. Multilevel inverters reduce this problem to some extent, with higher number of levels. But the complexity of the power circuit increases with an increase in the number of inverter voltage levels. In this paper a five-level inverter structure is proposed for open-end winding induction motor (IM) drives, by cascading only two conventional two-level and three-level inverters, with the elimination of the common mode voltage over the entire modulation range. The DC link power supply requirement is also optimized by means of DC link capacitor voltage balancing, with PWM control., using only inverter switching state redundancies. The proposed power circuit gives a simple power bits structure.
Resumo:
This paper proposes a multilevel inverter which produces hexagonal voltage space vector structure in lower modulation region and a 12-sided polygonal space vector structure in the over-modulation region. Normal conventional multilevel inverter produces 6n +/- 1 (n=odd) harmonics in the phase voltage during over-modulation and in the extreme square wave mode operation. However, this inverter produces a 12-sided polygonal space vector location leading to the elimination of 6n 1 (n=odd) harmonics in over-modulation region extending to a final 12-step mode operation. The inverter consists of three conventional cascaded two level inverters with asymmetric dc bus voltages. The switching frequency of individual inverters is kept low throughout the modulation index. In the low speed region, hexagonal space phasor based PWM scheme and in the higher modulation region, 12-sided polygonal voltage space vector structure is used. Experimental results presented in this paper shows that the proposed converter is suitable for high power applications because of low harmonic distortion and low switching losses.
Resumo:
In this paper, a novel 12-sided polygonal space vector structure is proposed for an induction motor drive. The space vector pattern presented in this paper consists of two 12-sided concentric polygons with the outer polygon having a radius double the inner one. As compared to previously reported 12-sided polygonal space vector structures, this paper subdivides the space vector plane into smaller sized triangles. This helps in reducing the switching frequency of the inverters without deteriorating the output voltage quality. It also reduces the device ratings and dv/dt stress on the devices to half. At the same time, other benefits obtained from the existing 12-sided space vector structure, such as increased linear modulation range and complete elimination of 5th and 7th order harmonics in the phase voltage, are also retained in this paper. The space vector structure is realized by feeding an open-end induction motor with two conventional three-level neutral point clamped (NPC) inverters with asymmetric isolated dc link voltage sources. The neutral point voltage fluctuations in the three-level NPC inverters are eliminated by utilizing the switching state multiplicities for a space vector point. The pulsewidth modulation timings are calculated using sampled reference waveform amplitudes and are explained in detail in this paper. Experimental verification on a laboratory prototype shows that this configuration may be considered suitable for high power drives.
Resumo:
A new technique for reducing the torque pulsations in a conventional current source inverter fed induction motor drive is presented. This does not attempt to improve the current waveforms, but modifies the airgap MMF directly. This is based on the use of a motor with two sets of balanced phase windings, with a 30 electrical degree phase difference between them, and each set being fed from a conventional current source inverter. The two inverters are further connected in series so that they can operate from the same current source. As a consequence of this arrangement, the voltage rating of the components of each inverter is reduced, along with reduced torque ripple. This scheme has been experimentally verified and compared with the performance of a conventional scheme.
Resumo:
This paper describes the method of field orientation of the stator current vector with respect to the stator, mutual, and rotor flux vectors, for the control of an induction motor fed from a current source inverter (CSI). A control scheme using this principle is described for orienting the stator current with respect to the rotor flux, as this gives natural decoupling between the current coordinates. A dedicated microcomputer system developed for implementing this scheme has been described. The experimental results are also presented.
Resumo:
Though silicon tunnel field effect transistor (TFET) has attracted attention for sub-60 mV/decade subthreshold swing and very small OFF current (IOFF), its practical application is questionable due to low ON current (ION) and complicated fabrication process steps. In this paper, a new n-type classical-MOSFET-alike tunnel FET architecture is proposed, which offers sub-60 mV/decade subthreshold swing along with a significant improvement in ION. The enhancement in ION is achieved by introducing a thin strained SiGe layer on top of the silicon source. Through 2D simulations it is observed that the device is nearly free from short channel effect (SCE) and its immunity towards drain induced barrier lowering (DIBL) increases with increasing germanium mole fraction. It is also found that the body bias does not change the drive current but after body current gets affected. An ION of View the MathML source and a minimum average subthreshold swing of 13 mV/decade is achieved for 100 nm channel length device with 1.2 V supply voltage and 0.7 Ge mole fraction, while maintaining the IOFF in fA range.
Resumo:
A novel dodecagonal space vector structure for induction motor drive is presented in this paper. It consists of two dodecagons, with the radius of the outer one twice the inner one. Compared to existing dodecagonal space vector structures, to achieve the same PWM output voltage quality, the proposed topology lowers the switching frequency of the inverters and reduces the device ratings to half. At the same time, other benefits obtained from existing dodecagonal space vector structure are retained here. This includes the extension of the linear modulation range and elimination of all 6+/-1 harmonics (n=odd) from the phase voltage. The proposed structure is realized by feeding an open-end winding induction motor with two conventional three level inverters. A detailed calculation of the PWM timings for switching the space vector points is also presented. Simulation and experimental results indicate the possible application of the proposed idea for high power drives.
Resumo:
A three-level space phasor generation scheme with common mode elimination and with reduced power device count is proposed for an open end winding induction motor in this paper. The open end winding induction motor is fed by the three-level inverters from both sides. Each two level inverter is formed by cascading two two-level inverters. By sharing the bottom inverter for the two three-level inverters on either side, the power device count is reduced. The switching states with zero common mode voltage variation are selected for PWM switching so that there is no alternating common mode voltage in the pole voltages as well as in phase voltages. Only two isolated DC-links, with half the voltage rating of a conventional three-level neutral point clamped inverter, are needed for the proposed scheme.
Resumo:
A multilevel inverter with 12-sided polygonal voltage space vector structure is proposed in this paper. The present scheme provides elimination of common mode voltage variation and 5(th) and 7(th) order harmonics in the entire operating range of the drive. The proposed multi level structure is achieved by cascading only the conventional two-level inverters with asymmetrical DC link voltages. The bandwidths problems associated with conventional hexagonal voltage space vector structure current controllers, due to the presence of 5(th) and 7(th) harmonics, in the over modulation region, is absent in the present 12-sided structure. So a linear voltage control up to 12-step operation is possible, from the present twelve sided scheme, with less current control complexity. An open-end winding structure is used for the induction motor drive.
Resumo:
This paper proposes a new five-level inverter topology for open-end winding induction motor (IM) drive. The popular existing circuit configurations for five-level inverter include the NPC inverter and flying capacitor topologies. Compared to the NPC inverter, the proposed topology eliminates eighteen clamping diodes having different voltage ratings in the present circuit. Moreover it requires only one capacitor bank per phase, whereas flying capacitor schemes for five level topologies require six capacitor banks per phase. The proposed topology is realized by feeding the phase winding of an open-end induction motor with two-level inverters in series with flying capacitors. The flying capacitor voltages are balanced using the switching state redundancy for full modulation range. The proposed inverter scheme is capable of producing two-level to five-level pulse width modulated voltage across the phase winding depending on the modulation range. Additionally, in case of any switch failure in the flying capacitor connection, the proposed inverter topology can be operated as a three-level inverter for full modulation range. The proposed scheme is experimentally verified on a four pole, 5hp induction motor drive.
Resumo:
Utilizing a circuit model [1, 2] of an induction motor, a simplified analysis of steady state performance of a voltage controlled induction motor (VCIM) drive is described in this paper. By solving a set of nonlinear algebraic equations which describe the VCIM drive under steady operation, the operating variables such as constant components of torque, rotor flux linkages, fundamental components of stator voltage and current and phase angle are obtained for any given value of slip, triggering angle and supply voltage.
Resumo:
This paper presents a five-level inverter scheme with four two-level inverters for a four-pole induction motor (IM) drive. In a conventional three-phase four-pole IM, there exists two identical voltage-profile winding coil groups per phase around the armature, which are connected in series and spatially apart by two pole pitches. In this paper, these two identical voltage-profile pole-pair winding coils in each phase of the IM are disconnected and fed from four two-level inverters from four sides of the windings with one-fourth dc-link voltage as compared to a conventional five-level neutral-point-clamped inverter. The scheme presented in this paper does not require any special design modification for the induction machine. For this paper, a four-pole IM drive is used, and the scheme can be easily extended to IMs with more than four poles. The proposed scheme is experimentally verified on a four-pole 5-hp IM drive.