27 resultados para Refractive errors - Epidemiology

em Indian Institute of Science - Bangalore - Índia


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: Proposing an image reconstruction technique, algebraic reconstruction technique-refraction correction (ART-rc). The proposed method takes care of refractive index mismatches present in gel dosimeter scanner at the boundary, and also corrects for the interior ray refraction. Polymer gel dosimeters with high dose regions have higher refractive index and optical density compared to the background medium, these changes in refractive index at high dose results in interior ray bending. Methods: The inclusion of the effects of refraction is an important step in reconstruction of optical density in gel dosimeters. The proposed ray tracing algorithm models the interior multiple refraction at the inhomogeneities. Jacob's ray tracing algorithm has been modified to calculate the pathlengths of the ray that traverses through the higher dose regions. The algorithm computes the length of the ray in each pixel along its path and is used as the weight matrix. Algebraic reconstruction technique and pixel based reconstruction algorithms are used for solving the reconstruction problem. The proposed method is tested with numerical phantoms for various noise levels. The experimental dosimetric results are also presented. Results: The results show that the proposed scheme ART-rc is able to reconstruct optical density inside the dosimeter better than the results obtained using filtered backprojection and conventional algebraic reconstruction approaches. The quantitative improvement using ART-rc is evaluated using gamma-index. The refraction errors due to regions of different refractive indices are discussed. The effects of modeling of interior refraction in the dose region are presented. Conclusions: The errors propagated due to multiple refraction effects have been modeled and the improvements in reconstruction using proposed model is presented. The refractive index of the dosimeter has a mismatch with the surrounding medium (for dry air or water scanning). The algorithm reconstructs the dose profiles by estimating refractive indices of multiple inhomogeneities having different refractive indices and optical densities embedded in the dosimeter. This is achieved by tracking the path of the ray that traverses through the dosimeter. Extensive simulation studies have been carried out and results are found to be matching that of experimental results. (C) 2015 American Association of Physicists in Medicine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Prequantization has been forwarded as a means to improve the performance of double phase holograms (DPHs). We show here that any improvement (even under the best of conditions) is not large enough to help the DPH to compete favourably with other holograms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An empirical relation for temperature–independent molar polarization is suggested. When this relation was used, the thermal expansivity was estimated correctly from refractive index data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple moire method for the direct measurement of refractive indices is presented. The change of magnification and/or distortion of the image of a linear grating when viewed through a refractive index field is amplified by means of moire fringes and is measured directly. Relations between the index of refraction and fringe spacing are derived and have been verified experimentally.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conventional methods for determining the refractive index demand specimens of optical quality, the preparation of which is often very difficult. An indirect determination by matching the refractive indices of specimen and immersion liquid is a practical alternative for photoelastic specimen of nonoptical quality. An experimental arrangement used for this technique and observations made while matching the refractive indices of three different specimens are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Epidemiology of symptomatic rotaviruses from Bangalore and Mysore in Southern India was investigated. While serotype G3 predominated throughout the 7-year study period from 1988 to 1994 in Bangalore, serotype G1 was more predominant than serotype G3 in Mysore during 1993 and 1994. Serotype G2 strains were either not detected or infrequently observed in both the cities. However, several strains with subgroup I and lsquoshortrsquo RNA pattern that exhibited high reactivity with typing MAbs specific for serotype 2 as well as other serotypes were detected throughout the period. Among the nonserotypeable strains from both cities, several exhibited dual subgroup (SGI+II) or subgroup I specificity and lsquolongrsquo RNA pattern indicating their probable animal origin. Notably, a gradual, yet highly significant reduction in rotavirus gastroenteritis, from 45.3% in 1988 to 1.8% during 1994, was observed in Bangalore in stark contrast to the consistently high (about 34%) incidence of asymptomatic infections among neonates by I321-like G10P11 type strains during the same period. Moreover, I321-like asymptomatic strains were not detected in children with diarrhea.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Effective usage of image guidance by incorporating the refractive index (RI) variation in computational modeling of light propagation in tissue is investigated to assess its impact on optical-property estimation. With the aid of realistic patient breast three-dimensional models, the variation in RI for different regions of tissue under investigation is shown to influence the estimation of optical properties in image-guided diffuse optical tomography (IG-DOT) using numerical simulations. It is also shown that by assuming identical RI for all regions of tissue would lead to erroneous estimation of optical properties. The a priori knowledge of the RI for the segmented regions of tissue in IG-DOT, which is difficult to obtain for the in vivo cases, leads to more accurate estimates of optical properties. Even inclusion of approximated RI values, obtained from the literature, for the regions of tissue resulted in better estimates of optical properties, with values comparable to that of having the correct knowledge of RI for different regions of tissue.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new experimental technique is proposed to determine refractive indices of liquids and isotropic solids at different wavelengths. A Pellin-Broca hollow prism filled with a liquid sample produces the spectrum (of the liquid prism) on the photographic plate of the camera. A plane reflector, mounted at a small angle to the normal of the exit face of the prism, also forms a direct image of the collimator slit in the plane of the same photographic plate. All the necessary information for determining the refractive indices (for different wavelengths) is extracted directly from the spectrogram without using any goniometric system. Experiments are conducted with the liquid prisms of isopropyl alcohol, water, and benzene. The results of the experiments are compared with those obtained by a Pulfrich refractometer (critical angle method). The proposed new technique gives the refractive indices for visible and invisible spectral lines to an accuracy of 2x10(-5). (C) 1997 Society of Photo-Optical Instrumentation Engineers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The lifetime calculation of large dense sensor networks with fixed energy resources and the remaining residual energy have shown that for a constant energy resource in a sensor network the fault rate at the cluster head is network size invariant when using the network layer with no MAC losses.Even after increasing the battery capacities in the nodes the total lifetime does not increase after a max limit of 8 times. As this is a serious limitation lots of research has been done at the MAC layer which allows to adapt to the specific connectivity, traffic and channel polling needs for sensor networks. There have been lots of MAC protocols which allow to control the channel polling of new radios which are available to sensor nodes to communicate. This further reduces the communication overhead by idling and sleep scheduling thus extending the lifetime of the monitoring application. We address the two issues which effects the distributed characteristics and performance of connected MAC nodes. (1) To determine the theoretical minimum rate based on joint coding for a correlated data source at the singlehop, (2a) to estimate cluster head errors using Bayesian rule for routing using persistence clustering when node densities are the same and stored using prior probability at the network layer, (2b) to estimate the upper bound of routing errors when using passive clustering were the node densities at the multi-hop MACS are unknown and not stored at the multi-hop nodes a priori. In this paper we evaluate many MAC based sensor network protocols and study the effects on sensor network lifetime. A renewable energy MAC routing protocol is designed when the probabilities of active nodes are not known a priori. From theoretical derivations we show that for a Bayesian rule with known class densities of omega1, omega2 with expected error P* is bounded by max error rate of P=2P* for single-hop. We study the effects of energy losses using cross-layer simulation of - large sensor network MACS setup, the error rate which effect finding sufficient node densities to have reliable multi-hop communications due to unknown node densities. The simulation results show that even though the lifetime is comparable the expected Bayesian posterior probability error bound is close or higher than Pges2P*.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: India has the third largest HIV-1 epidemic with 2.4 million infected individuals. Molecular epidemiological analysis has identified the predominance of HIV-1 subtype C (HIV-1C). However, the previous reports have been limited by sample size, and uneven geographical distribution. The introduction of HIV-1C in India remains uncertain due to this lack of structured studies. To fill the gap, we characterised the distribution pattern of HIV-1 subtypes in India based on data collection from nationwide clinical cohorts between 2007 and 2011. We also reconstructed the time to the most recent common ancestor (tMRCA) of the predominant HIV-1C strains. Methodology/Principal Findings: Blood samples were collected from 168 HIV-1 seropositive subjects from 7 different states. HIV-1 subtypes were determined using two or three genes, gag, pol, and env using several methods. Bayesian coalescent-based approach was used to reconstruct the time of introduction and population growth patterns of the Indian HIV-1C. For the first time, a high prevalence (10%) of unique recombinant forms (BC and A1C) was observed when two or three genes were used instead of one gene (p<0.01; p = 0.02, respectively). The tMRCA of Indian HIV-1C was estimated using the three viral genes, ranged from 1967 (gag) to 1974 (env). Pol-gene analysis was considered to provide the most reliable estimate 1971, (95% CI: 1965-1976)]. The population growth pattern revealed an initial slow growth phase in the mid-1970s, an exponential phase through the 1980s, and a stationary phase since the early 1990s. Conclusions/Significance: The Indian HIV-1C epidemic originated around 40 years ago from a single or few genetically related African lineages, and since then largely evolved independently. The effective population size in the country has been broadly stable since the 1990s. The evolving viral epidemic, as indicated by the increase of recombinant strains, warrants a need for continued molecular surveillance to guide efficient disease intervention strategies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have developed a technique to measure the absolute frequencies of optical transitions by using an evacuated Rb-stabilized ring-cavity resonator as a transfer cavity. The absolute frequency of the Rb D-2 line (at 780 nm) used to stabilize the cavity is known and allows us to determine the absolute value of the unknown frequency. We study wavelength-dependent errors due to dispersion at the cavity mirrors by measuring the frequency of the same transition in the Cs D-2 line (at 852 nm) at three cavity lengths. The spread in the values shows that dispersion errors are below 30 kHz, corresponding to a relative precision of 10(-10). We give an explanation for reduced dispersion errors in the ring-cavity geometry by calculating errors due to the lateral shift and the phase shift at the mirrors, and show that they are roughly equal but occur with opposite signs. We have earlier shown that diffraction errors (due to Guoy phase) are negligible in the ring-cavity geometry compared to a linear cavity; the reduced dispersion error is another advantage. Our values are consistent with measurements of the same transition using the more expensive frequency-comb technique. Our simpler method is ideally suited for measuring hyperfine structure, fine structure, and isotope shifts, up to several hundreds of gigahertz.