60 resultados para Quantities and measurements

em Indian Institute of Science - Bangalore - Índia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report the optical spectra and single crystal magnetic susceptibility of the one-dimensional antiferromagnet KFeS2. Measurements have been carried out to ascertain the spin state of Fe3+ and the nature of the magnetic interactions in this compound. The optical spectra and magnetic susceptibility could be consistently interpreted using a S = 1/2 spin ground state for the Fe3+ ion. The features in the optical spectra have been assigned to transitions within the d-electron manifold of the Fe3+ ion, and analysed in the strong field limit of the ligand field theory. The high temperature isotropic magnetic susceptibility is typical of a low-dimensional system and exhibits a broad maximum at similar to 565 K. The susceptibility shows a well defined transition to a three dimensionally ordered antiferromagnetic state at T-N = 250 K. The intra and interchain exchange constants, J and J', have been evaluated from the experimental susceptibilities using the relationship between these quantities, and chi(max), T-max, and T-N for a spin 1/2 one-dimensional chain. The values are J = -440.71 K, and J' = 53.94 K. Using these values of J and J', the susceptibility of a spin 1/2 Heisenberg chain was calculated. A non-interacting spin wave model was used below T-N. The susceptibility in the paramagnetic region was calculated from the theoretical curves for an infinite S = 1/2 chain. The calculated susceptibility compares well with the experimental data of KFeS2. Further support for a one-dimensional spin 1/2 model comes from the fact that the calculated perpendicular susceptibility at 0K (2.75 x 10(-4) emu/mol) evaluated considering the zero point reduction in magnetization from spin wave theory is close to the projected value (2.7 x 10(-4) emu/mol) obtained from the experimental data.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Despite great advances in very large scale integrated-circuit design and manufacturing, performance of even the best available high-speed, high-resolution analog-to-digital converter (ADC) is known to deteriorate while acquiring fast-rising, high-frequency, and nonrepetitive waveforms. Waveform digitizers (ADCs) used in high-voltage impulse recordings and measurements are invariably subjected to such waveforms. Errors resulting from a lowered ADC performance can be unacceptably high, especially when higher accuracies have to be achieved (e.g., when part of a reference measuring system). Static and dynamic nonlinearities (estimated independently) are vital indices for evaluating performance and suitability of ADCs to be used in such environments. Typically, the estimation of static nonlinearity involves 10-12 h of time or more (for a 12-b ADC) and the acquisition of millions of samples at high input frequencies for dynamic characterization. ADCs with even higher resolution and faster sampling speeds will soon become available. So, there is a need to reduce testing time for evaluating these parameters. This paper proposes a novel and time-efficient method for the simultaneous estimation of static and dynamic nonlinearity from a single test. This is achieved by conceiving a test signal, comprised of a high-frequency sinusoid (which addresses dynamic assessment) modulated by a low-frequency ramp (relevant to the static part). Details of implementation and results on two digitizers are presented and compared with nonlinearities determined by the existing standardized approaches. Good agreement in results and time savings achievable indicates its suitability.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Despite great advances in very large scale integrated-circuit design and manufacturing, performance of even the best available high-speed, high-resolution analog-to-digital converter (ADC) is known to deteriorate while acquiring fast-rising, high-frequency, and nonrepetitive waveforms. Waveform digitizers (ADCs) used in high-voltage impulse recordings and measurements are invariably subjected to such waveforms. Errors resulting from a lowered ADC performance can be unacceptably high, especially when higher accuracies have to be achieved (e.g., when part of a reference measuring system). Static and dynamic nonlinearities (estimated independently) are vital indices for evaluating performance and suitability of ADCs to be used in such environments. Typically, the estimation of static nonlinearity involves 10-12 h of time or more (for a 12-b ADC) and the acquisition of millions of samples at high input frequencies for dynamic characterization. ADCs with even higher resolution and faster sampling speeds will soon become available. So, there is a need to reduce testing time for evaluating these parameters. This paper proposes a novel and time-efficient method for the simultaneous estimation of static and dynamic nonlinearity from a single test. This is achieved by conceiving a test signal, comprised of a high-frequency sinusoid (which addresses dynamic assessment) modulated by a low-frequency ramp (relevant to the static part). Details of implementation and results on two digitizers are presented and compared with nonlinearities determined by the existing standardized approaches. Good agreement in results and time savings achievable indicates its suitability.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Using the treatment of Smith, et al.,1 charge distributions in several aliphatic alcohols and consequently their dipole moments have been evaluated. The dipole moments of trichloroethanol (2.04 D) and 1,3-dichloropropan-2-ol (2.11 D) have been measured in benzene solution at 35°. The results of evaluation and measurements are interpreted in terms of the occurrence of intramolecular interaction between the hydroxyl hydrogen and an acceptor atom X (halogen or oxygen) at the β-carbon atom.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

An extracellular xylanase was purified to homogeneity from the culture filtrate of the thermophilic fungus, Humicola lanuginosa (Griffon and Maublanc) Bunce and its properties were studied. A fourfold purification and a yield of 8% were achieved. The molecular-weight of the protein was found to be 22,500 based on electrophoretic mobility and 29,000 by gel filtration behavior. The protein is rich in acidic amino acids, glycine and tyrosine, and poor in sulfur-containing amino acids. The kinetic properties of the enzyme are similar to those of other fungal xylanases. The enzyme shows high affinity toward larchwood xylan (Km = 0.91 mg/ml) and hydrolyzes only xylan. The enzyme becomes inactivated when stored for more than 2 months at −20 °C in the dry state. Such an inactivation has not been reported so far for any xylanase. Using chromatographic techniques, one species of protein differing from the native protein in charge but enzymatically active was isolated in low yields. However, a large molecular-weight species of the protein devoid of enzyme activity was isolated in substantial quantities and further characterized. Based on ultracentrifugation and gel electrophoretic studies, it was concluded that this species may be an aggregate of the native protein and that such an aggregation might be taking place on storage in the dry state at −20 °C, leading to loss in activity.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The well-known linear relationship (T?S# =??H# +?, where 1 >? > 0,? > 0) between the entropy (?S#) and the enthalpy (?H#) of activation for reactions in polar liquids is investigated by using a molecular theory. An explicit derivation of this linear relation from first principles is presented for an outersphere charge transfer reaction. The derivation offers microscopic interpretation for the quantities? and?. It has also been possible to make connection with and justify the arguments of Bell put forward many years ago.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

An interesting topic for quite some time is an intermediate phase observed in chalcogenide glasses, which is related to network connectivity and rigidity. This phenomenon is exhibited by Si-Te-In glasses also. It has been addressed here by carrying out detailed thermal investigations by using Alternating Differential Scanning Calorimetry technique. An effort has also been made to determine the stability of these glasses using the data obtained from different thermodynamic quantities and crystallization kinetics of these glasses. Electrical switching behavior by recording I-V characteristics and variation of switching voltages with indium composition have been studied in these glasses for phase change memory applications. (C) 2011 Elsevier Inc. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We have investigated thermal properties of bulk Si15Te85-xAgx (4 <= x <= 20) glasses in detail, through alternating differential scanning calorimetry experiments. The composition dependence of thermal parameters reveal the signatures of rigidity percolation and chemical threshold at compositions x = 12 and x = 19, respectively. The stability and glass forming ability of these glasses have also been determined using the data obtained from different thermodynamic quantities and it is found that the Si15Te85-xAgx glasses in the region 12 <= x <= 17 are more stable when compared to other glasses of the same series. Further, the blueshift observed in Raman spectroscopy investigations, in the composition range 12 <= x <= 13, support the occurrence of stiffness threshold in this composition range. All Si15Te85-xAgx (4 <= x <= 20) glasses are found to exhibit memory type switching (for sample thickness 0.25 mm) in the input current range 3-9 mA. The effect of rigidity percolation and chemical thresholds on switching voltages are observed at x = 12 and 19, respectively. (C) 2012 American Institute of Physics. [doi:10.1063/1.3682759]

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In graphene, the valleys represent spinlike quantities and can act as a physical resource in valley-based electronics to produce novel quantum computation schemes. Here we demonstrate a direct route to tune and read the valley quantum states of disordered graphene by measuring the mesoscopic conductance fluctuations. We show that the conductance fluctuations in graphene at low temperatures are reduced by a factor of 4 when valley triplet states are gapped in the presence of short-range potential scatterers at high carrier densities. We also show that this implies a gate tunable universal symmetry class that outlines a fundamental feature arising from graphene's unique crystal structure.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A study of the history and philosophy of the contribution of India towards the exploration of space since antiquity provides interesting insights. The contributions are described during the three periods namely: (1) the ten millenniums from 10,000 BC with a twilight period up to 900 AD; (2) the ten centuries from 900 AD to 1900 AD; and (3) the ten decades from 1900 AD to 2000 AD; called mythological, medieval, and modern respectively. Some important events during the above periods provide a reference view of the progress. The Vedas during the mythological period and the Siddhantas during the medieval periods, which are based on astronomical observations, indicate that the Indian contribution preceded other cultures. But most Western historians ignore this fact time and again in spite of many proofs provided to the contrary. This chapter also shows that Indians had the proper scientific attitude of developing any physical theory through the triplet of mind, model, and measurements. It is this same triplet that forms the basis of the present day well known Kalman filter technique. Up to about 1500 BC the Indian contribution was leading but during foreign invasion and occupation it lagged and has been improving only after independence.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Perception of operator influences ultrasound image acquisition and processing. Lower costs are attracting new users to medical ultrasound. Anticipating an increase in this trend, we conducted a study to quantify the variability in ultrasonic measurements made by novice users and identify methods to reduce it. We designed a protocol with four presets and trained four new users to scan and manually measure the head circumference of a fetal phantom with an ultrasound scanner. In the first phase, the users followed this protocol in seven distinct sessions. They then received feedback on the quality of the scans from an expert. In the second phase, two of the users repeated the entire protocol aided by visual cues provided to them during scanning. We performed off-line measurements on all the images using a fully automated algorithm capable of measuring the head circumference from fetal phantom images. The ground truth (198.1 +/- 1.6 mm) was based on sixteen scans and measurements made by an expert. Our analysis shows that: (1) the inter-observer variability of manual measurements was 5.5 mm, whereas the inter-observer variability of automated measurements was only 0.6 mm in the first phase (2) consistency of image appearance improved and mean manual measurements was 4-5 mm closer to the ground truth in the second phase (3) automated measurements were more precise, accurate and less sensitive to different presets compared to manual measurements in both phases. Our results show that visual aids and automation can bring more reproducibility to ultrasonic measurements made by new users.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

By using high-resolution observations of nearly co-temporal and co-spatial Solar Optical Telescope spectropolarimeter and X-Ray Telescope coronal X-ray data onboard Hinode, we revisit the problematic relationship between global magnetic quantities and coronal X-ray brightness. Co-aligned vector magnetogram and X-ray data were used for this study. The total X-ray brightness over active regions is well correlated with integrated magnetic quantities such as the total unsigned magnetic flux, the total unsigned vertical current, and the area-integrated square of the vertical and horizontal magnetic fields. On accounting for the inter-dependence of the magnetic quantities, we inferred that the total magnetic flux is the primary determinant of the observed integrated X-ray brightness. Our observations indicate that a stronger coronal X-ray flux is not related to a higher non-potentiality of active-region magnetic fields. The data even suggest a slightly negative correlation between X-ray brightness and a proxy of active-region non-potentiality. Although there are small numerical differences in the established correlations, the main conclusions are qualitatively consistent over two different X-ray filters, the Al-poly and Ti-poly filters, which confirms the strength of our conclusions and validate and extend earlier studies that used low-resolution data. We discuss the implications of our results and the constraints they set on theories of solar coronal heating.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Partial discharges in a gaseous interface due to the presence of a dielectric between two uniform field electrodes in air at different pressures from 0.5 to 685 mm Hg have been studied and measurements of inception and extinction voltages, number of pulses and their charge magnitudes at inception are reported. It has been observed that the extinction voltage can be as low as 70% of the inception voltage suggesting that the working voltage in such cases should be about 30% lower than the observed inception voltage. Small magnitude pulses are found to be more in number than large magnitude pulses. The charge is found to be pressure dependent. The results have been explained on the basis of an equivalent circuit consisting of resistance and capacitance in which the discharge gap functions as a switch.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This article presents the analysis and design of a compact multi-layer layer, high selectivity wideband bandpass filter using stub loaded and `U' shaped resonators over a slotted bottom ground plane. While the resonators with folded open circuit stub loadings create the desired bandpass characteristics. the IT shaped resonators reduce the size of filter. The slotted bottom ground plane is used to enhance the coupling to achieve the desired bandwidth. The proposed filter has been analyzed using circuit model, and the results were verified through full wave simulations and measurements. The fabricated filter is compact and measures a size of 18 mm x 25 mm x 1.6 MM. (C) 2010 Wiley Periodicals, Inc. Microwave Opt Technol Lett 52: 1387-1389, 2010: Published online in Wiley InterScience (www.interscience.wiley.com).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Higher order LCL filters are essential in meeting the interconnection standard requirement for grid-connected voltage source converters. LCL filters offer better harmonic attenuation and better efficiency at a smaller size when compared to the traditional L filters. The focus of this paper is to analyze the LCL filter design procedure from the point of view of power loss and efficiency. The IEEE 1547-2008 specifications for high-frequency current ripple are used as a major constraint early in the design to ensure that all subsequent optimizations are still compliant with the standards. Power loss in each individual filter component is calculated on a per-phase basis. The total inductance per unit of the LCL filter is varied, and LCL parameter values which give the highest efficiency while simultaneously meeting the stringent standard requirements are identified. The power loss and harmonic output spectrum of the grid-connected LCL filter is experimentally verified, and measurements confirm the predicted trends.