9 resultados para Program C : Delivery Management of Built Assets

em Indian Institute of Science - Bangalore - Índia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Results of performance measurement of a small cooling capacity laboratory model of an adsorption refrigeration system for thermal management of electronics are compiled. This adsorption cooler was built with activated carbon as the adsorbent and HFC 134a as the refrigerant to produce a cooling capacity under 5 W using waste heat up to 90 degrees C. The thermal compression process is obtained from an ensemble of four solid sorption compressors. Parametric study was conducted with cycle times of 16 and 20 min, heat source temperatures from 73 to 87 degrees C and cooling loads from 3 to 4.9W. Overall system performance is analyzed using two indicators, namely, cooling effectiveness and normalized exergetic efficiency. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Uncertainty plays an important role in water quality management problems. The major sources of uncertainty in a water quality management problem are the random nature of hydrologic variables and imprecision (fuzziness) associated with goals of the dischargers and pollution control agencies (PCA). Many Waste Load Allocation (WLA)problems are solved by considering these two sources of uncertainty. Apart from randomness and fuzziness, missing data in the time series of a hydrologic variable may result in additional uncertainty due to partial ignorance. These uncertainties render the input parameters as imprecise parameters in water quality decision making. In this paper an Imprecise Fuzzy Waste Load Allocation Model (IFWLAM) is developed for water quality management of a river system subject to uncertainty arising from partial ignorance. In a WLA problem, both randomness and imprecision can be addressed simultaneously by fuzzy risk of low water quality. A methodology is developed for the computation of imprecise fuzzy risk of low water quality, when the parameters are characterized by uncertainty due to partial ignorance. A Monte-Carlo simulation is performed to evaluate the imprecise fuzzy risk of low water quality by considering the input variables as imprecise. Fuzzy multiobjective optimization is used to formulate the multiobjective model. The model developed is based on a fuzzy multiobjective optimization problem with max-min as the operator. This usually does not result in a unique solution but gives multiple solutions. Two optimization models are developed to capture all the decision alternatives or multiple solutions. The objective of the two optimization models is to obtain a range of fractional removal levels for the dischargers, such that the resultant fuzzy risk will be within acceptable limits. Specification of a range for fractional removal levels enhances flexibility in decision making. The methodology is demonstrated with a case study of the Tunga-Bhadra river system in India.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The rhesus monkey Macaca mulatta and Hanuman langur Presbytis entellus are distributed all over the State of Himachal Pradesh, India. Although both species inhabit forested areas, only rhesus monkeys seem also to have become urbanized. There are about 200,000 rhesus monkeys and 120,000 Hanuman langurs. A three-year survey at Shimla showed an increasing trend in their populations. Potential threats to survival of these primates differ in the 12 districts. The two species differ in feeding and habitat preferences. People's feelings, perceptions and attitudes reward them point to an incipient man-monkey conflict and erosion of conservation ethics. A comprehensive management plan for these primates should be formulated, and involve local people. Copyright (C) 1996 Elsevier Science Limited

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Designing a heat sink based on a phase change material (PCM) under cyclic loading is a critical issue. For cyclic operation, it is required that the fraction of the PCM melting during the heating cycle should completely resolidify during the cooling period, so that that thermal storage unit can be operated for an unlimited number of cycles. Accordingly, studies are carried out to find the parameters influencing the behavior of a PCM under cyclic loading. A number of parameters are identified in the process, the most important ones being the duty cycle and heat transfer coefficient (h) for cooling. The required h or the required cooling period for complete resolidification for infinite cyclic operation of a conventional PCM-based heat sink is found to be very high and unrealistic with air cooling from the surface. To overcome this problem, the conventional design is modified where h and the area exposed to heat transfer can be independently controlled. With this arrangement, the enhanced area provided for cooling keeps h within realistic limits. Analytical investigation is carried out to evaluate the thermal performance of this modified PCM-based heat sink in comparison to those with conventional designs. Experiments are also performed on both the conventional and the modified PCM-based heat sinks to validate the new findings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A fuzzy waste-load allocation model, FWLAM, is developed for water quality management of a river system using fuzzy multiple-objective optimization. An important feature of this model is its capability to incorporate the aspirations and conflicting objectives of the pollution control agency and dischargers. The vagueness associated with specifying the water quality criteria and fraction removal levels is modeled in a fuzzy framework. The goals related to the pollution control agency and dischargers are expressed as fuzzy sets. The membership functions of these fuzzy sets are considered to represent the variation of satisfaction levels of the pollution control agency and dischargers in attaining their respective goals. Two formulations—namely, the MAX-MIN and MAX-BIAS formulations—are proposed for FWLAM. The MAX-MIN formulation maximizes the minimum satisfaction level in the system. The MAX-BIAS formulation maximizes a bias measure, giving a solution that favors the dischargers. Maximization of the bias measure attempts to keep the satisfaction levels of the dischargers away from the minimum satisfaction level and that of the pollution control agency close to the minimum satisfaction level. Most of the conventional water quality management models use waste treatment cost curves that are uncertain and nonlinear. Unlike such models, FWLAM avoids the use of cost curves. Further, the model provides the flexibility for the pollution control agency and dischargers to specify their aspirations independently.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Guanylyl cyclase C (GCC), a member of the family of membrane bound guanylyl cyclases is the receptor for the heat-stable enterotoxin (ST) peptides and the guanylin family of endogenous peptides. GCC is activated upon ligand binding to increase intracellular cGMP levels, which in turn activates other downstream signalling events in the cell. GCC is also activated in vitro by nonionic detergents. We have used the T84 cell line as a model system to investigate the regulation of GCC activity by ATP. Ligand-stimulated GCC activity is potentiated in the presence of ATP, whereas detergent-stimulated activity is inhibited. The potentiation of GCC activity by ATP is dependent on the presence of Mg2+ ions, and is probably brought about by a direct binding of Mg-ATP to GCC. The protein kinase-like domain of GCC, which has earlier been shown to play a critical role in the regulation of GCC activity, may be a possible site for the binding of Mg-ATP to GCC.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A bacterial consortium consisting of strains belongings to the genus Klebsiella and Rhodococcus quantitatively converts 1-, 3- and 7-substituted xanthines to their respective 8-oxo compounds.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In our earlier work ([1]) we proposed WLAN Manager (or WM) a centralised controller for QoS management of infrastructure WLANs based on the IEEE 802.11 DCF standards. The WM approach is based on queueing and scheduling packets in a device that sits between all traffic flowing between the APs and the wireline LAN, requires no changes to the AP or the STAs, and can be viewed as implementing a "Split-MAC" architecture. The objectives of WM were to manage various TCP performance related issues (such as the throughput "anomaly" when STAs associate with an AP with mixed PHY rates, and upload-download unfairness induced by finite AP buffers), and also to serve as the controller for VoIP admission control and handovers, and for other QoS management measures. In this paper we report our experiences in implementing the proposals in [1]: the insights gained, new control techniques developed, and the effectiveness of the WM approach in managing TCP performance in an infrastructure WLAN. We report results from a hybrid experiment where a physical WM manages actual TCP controlled packet flows between a server and clients, with the WLAN being simulated, and also from a small physical testbed with an actual AP.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A detailed investigation of the d.c. polarographic behaviour of vanadium(V),-(IV) and -(III) in glycine solutions has been made keeping the total glycine concentration at 0.1, 0.5 and 1.0 M and varying the pH of the solution. Experiments keeping the pH constant (using different ratios of glycine and glycine anion) and varying the glycine anion concentration, and also in predominantly anion solutions, have been made.