32 resultados para Preplanting refrigeration

em Indian Institute of Science - Bangalore - Índia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A thermodynamic analysis is presented for the two stage thermal compression process for an adsorption refrigeration cycle with HFC-134a as the working fluid and activated carbon as the adsorbent. Three specimens of varying achievable packing densities were evaluated. The influence of evaporating, condensing/adsorption and desorption temperatures was assessed through three performance indicators, namely,the uptake efficiency, the coefficient of performance and the exergetic efficiency. Conditions under which a two stage thermal compression process performs better than the single stage unit are identified. It is concluded that two stage thermal compression will be a viable proposition when the heat source temperature is low or when adsorption characteristics are weak or when adequate packing densities are difficult to realize. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the results of an investigation on the efficacy of hybrid compression process for refrigerant HFC 134a in cooling applications. The conventional mechanical compression is supplemented by thermal compression using a string of adsorption compressors. Activated carbon is the adsorbent for the thermal compression segment. The alternatives of bottoming either mechanical or thermal compression stages are investigated. It is shown that almost 40% energy saving is realizable by carrying out a part of the compression in a thermal compressor compared to the case when the entire compression is carried out in a single-stage mechanical compressor. The hybrid compression is feasible even when low grade heat is available. Some performance indictors are defined and evaluated for various configurations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of binary fluid systems in thermally driven vapour absorption and mechanically driven vapour compression refrigeration and heatpump cycles has provided an impetus for obtaining experimental date on caloric properties of such fluid mixtures. However, direct measurements of these properties are somewhat scarce in spite of the calorimetric techniques described in the literature being quite adequate. Most of the design data are derived through calculations using theoretical models and vapour-liquid equilibrium data. This article addresses the choice of working fluids and the current status on the data availability vis-a-vis engineering applications. Particular emphasis is on organic working fluid pairs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A comparative study has been carried out of R-12, 22, 125, 134a, 152a, 218, 245, 500, 502, 507 and 717 as working fluids in a vapour-compression refrigeration system. Two performance parameters were defined, which are expressed in reduced quantities for a corresponding-states comparison of these refrigerants in the temperature range -20 to 50-degrees-C. One is based on the product of temperature drop to pressure penalty ratio and the available volumetric heat of vaporisation at the evaporator; the other considers the effect of isentropic compression in the ideal gas state. It was shown that R-125, 507 and 218 could be better alternatives to R-12 than R-134a. Among these, R-218 has a lower maximum cycle pressure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors describe the constructional features of a controller for operating an autonomous refrigeration unit powered by a field of photovoltaic panels and backed up by a generator set. The controller enables three voltage levels of operation of an inverter to meet the start, run and off cycle conditions of the refrigerator compressor. The algorithm considers several input and output parameters and status signals from each subsystem of the unit to deduce a control strategy. Such units find application for storage of vaccines and life-saving medicines requiring uninterrupted refrigeration, in medical shops, rural health centres, veterinary laboratories etc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this paper is to present exergy charts for carbon dioxide (CO2) based on the new fundamental equation of state and the results of a thermodynamic analysis of conventional and trans-critical vapour compression refrigeration cycles using the data thereof. The calculation scheme is anchored on the Mathematica platform. There exist upper and lower bounds for the high cycle pressure for a given set of evaporating and pre-throttling temperatures. The maximum possible exergetic efficiency for each case was determined. Empirical correlations for exergetic efficiency and COP, valid in the range of temperatures studied here, are obtained. The exergy losses have been quantified. (C) 2003 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A theoretical analysis of the Gifford-McMahon cycle is presented. Expressions for the ideal refrigeration produced and the figure of merit are developed. Various losses occurring in a real machine are considered and equations to account for these losses are derived. Results are presented in graphical form.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A heat balance analysis of single stage Gifford-McMahon cycle cryorefrigerator is presented. Ideal refrigeration, actual refrigeration, net refrigeration and the various losses are tabulated. It is observed that pressure-volume losses account for a major fraction of the total losses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report the synthesis and properties of sphere-shaped microscale aggregates of bismuth telluride nanoplates. We obtain porous microspheres by reducing bismuth chloride and orthotelluric acid with hydrazine in the presence of thioglycolic acid-which serves as the shape-and size-directing agent-followed by room-temperature aging-which promotes nanoplate aggregation. Thin film assemblies of the nanoplate microspheres exhibit n-type behavior due to sulfur doping and a Seebeck coefficient higher than that reported for assemblies of chalcogenide nanostructures. Adaptation of our scalable approach to synthesize and hierarchically assemble nanostructures with controlled doping could be attractive for tailoring novel thermoelectric materials for applications in high-efficiency refrigeration and harvesting electricity from heat.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A numerical modelling technique for predicting the detailed performance of a double-inlet type two-stage pulse tube refrigerator has been developed. The pressure variations in the compressor, pulse tube, and reservoir were derived, assuming the stroke volume variation of the compressor to be sinusoidal. The relationships of mass flowrates, volume flowrates, and temperature as a function of time and position were developed. The predicted refrigeration powers are calculated by considering the effect of void volumes and the phase shift between pressure and mass flowrate. These results are compared with the experimental results of a specific pulse tube refrigerator configuration and an existing theoretical model. The analysis shows that the theoretical predictions are in good agreement with each other.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A laboratory model of a thermally driven adsorption refrigeration system with activated carbon as the adsorbent and 1,1,1,2-tetrafluoroethane (HFC 134a) as the refrigerant was developed. The single stage compression system has an ensemble of four adsorbers packed with Maxsorb II specimen of activated carbon that provide a near continuous flow which caters to a cooling load of up to 5W in the 5-18 degrees C region. The objective was to utilise the low grade thermal energy to drive a refrigeration system that can be used to cool some critical electronic components. The laboratory model was tested for it performance at various cooling loads with the heat source temperature from 73 to 93 degrees C. The pressure transients during heating and cooling phases were traced. The cyclic steady state and transient performance data are presented. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A two-stage pulse tube cryocooler (PTC) which produces a no-load temperature of similar to 2.5 K in its second stage at an operating frequency of 1.6 Hz has been designed and fabricated. The second stage of the system provides a refrigeration power of similar to 250 mW at 5.0 K. The system uses stainless steel meshes (mesh size 200) along with lead (Pb) granules and combinations of Pb, Er3Ni, and HoCu2 as the first and second stage regenerator materials, respectively. Experimental studies have been carried out on different pulse tube configurations by varying the dimensions of the pulse tubes and regenerators to arrive at the best one, which leads to the lowest no-load second stage cold head temperature. Using this configuration, detailed experimental studies have been conducted by varying the volume percentage ratios of the second stage regenerator materials such as HoCu2, Er3Ni, and Pb (with an average grain size of similar to 250 mu m). This article presents the results of our experimental studies on cryocoolers with the regenerator material arranged in layered structures. Comparative studies have also been presented for specific cases where the regenerator materials are arranged as a homogeneous mixture in the second stage. The experimental results clearly indicate that the design of PTCs should use only layered structures of regenerator materials and not homogenous mixtures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The saturated liquid density, varrholr, data along the liquid vapour coexistence curve published in the literature for several cryogenic liquids, hydrocarbons and halocarbon refrigerants are fitted to a generalized equation of the following form varrholr = 1 + A(1 − Tr + B(1 − Tr)β The values of β, the index in phase density differences power law, have been obtained by means of two approaches namely statistical treatment of saturated fluid phase density difference data and the existence of a maximum in T(varrho1 − varrhov) along the saturation curve. Values of the constants A and B are determined utilizing the fact that Tvarrho1 has a maximum at a characteristic temperature T. Values of A, B and β are tabulated for Ne, Ar, Kr, Xe, N2, O2, methane, ethane, propane, iso-butane, n-butane, propylene, ethylene, CO2, water, ammonia, refrigerants-11, 12, 12B1, 13, 13B1, 14, 21, 22, 23, 32, 40, 113, 114, 115, 142b, 152a, 216, 245 and azeotropes R-500, 502, 503, 504. The average error of prediction is less than 2%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this article, a general definition of the process average temperature has been developed, and the impact of the various dissipative mechanisms on 1/COP of the chiller evaluated. The present component-by-component black box analysis removes the assumptions regarding the generator outlet temperature(s) and the component effective thermal conductances. Mass transfer resistance is also incorporated into the absorber analysis to arrive at a more realistic upper limit to the cooling capacity. Finally, the theoretical foundation for the absorption chiller T-s diagram is derived. This diagrammatic approach only requires the inlet and outlet conditions of the chiller components and can be employed as a practical tool for system analysis and comparison. (C) 2000 Elsevier Science Ltd and IIR. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Results of performance measurement of a small cooling capacity laboratory model of an adsorption refrigeration system for thermal management of electronics are compiled. This adsorption cooler was built with activated carbon as the adsorbent and HFC 134a as the refrigerant to produce a cooling capacity under 5 W using waste heat up to 90 degrees C. The thermal compression process is obtained from an ensemble of four solid sorption compressors. Parametric study was conducted with cycle times of 16 and 20 min, heat source temperatures from 73 to 87 degrees C and cooling loads from 3 to 4.9W. Overall system performance is analyzed using two indicators, namely, cooling effectiveness and normalized exergetic efficiency. (C) 2011 Elsevier Ltd. All rights reserved.