198 resultados para Phasor measurement units.

em Indian Institute of Science - Bangalore - Índia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a method for placement of Phasor Measurement Units, ensuring the monitoring of vulnerable buses which are obtained based on transient stability analysis of the overall system. Real-time monitoring of phase angles across different nodes, which indicates the proximity to instability, the very purpose will be well defined if the PMUs are placed at buses which are more vulnerable. The issue is to identify the key buses where the PMUs should be placed when the transient stability prediction is taken into account considering various disturbances. Integer Linear Programming technique with equality and inequality constraints is used to find out the optimal placement set with key buses identified from transient stability analysis. Results on IEEE-14 bus system are presented to illustrate the proposed approach.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents methodologies for incorporating phasor measurements into conventional state estimator. The angle measurements obtained from Phasor Measurement Units are handled as angle difference measurements rather than incorporating the angle measurements directly. Handling in such a manner overcomes the problems arising due to the choice of reference bus. Current measurements obtained from Phasor Measurement Units are treated as equivalent pseudo-voltage measurements at the neighboring buses. Two solution approaches namely normal equations approach and linear programming approach are presented to show how the Phasor Measurement Unit measurements can be handled. Comparative evaluation of both the approaches is also presented. Test results on IEEE 14 bus system are presented to validate both the approaches.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The purpose of this article is to report the experience of design and testing of orifice plate-based flow measuring systems for evaluation of air leakages in components of air conditioning systems. Two of the flow measuring stations were designed with a beta value of 0.405 and 0.418. The third was a dual path unit with orifice plates of beta value 0.613 and 0.525. The flow rates covered with all the four were from 4-94 l/s and the range of Reynolds numbers is from 5600 to 76,000. The coefficients of discharge were evaluated and compared with the Stolz equation. Measured C-d values are generally higher than those obtained from the equation, the deviations being larger in the low Reynolds number region. Further, it is observed that a second-degree polynomial is inadequate to relate the pressure drop and flow rate. The lower Reynolds number limits set by standards appear to be somewhat conservative.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report a circuit technique to measure the on-chip delay of an individual logic gate (both inverting and non-inverting) in its unmodified form using digitally reconfigurable ring oscillator (RO). Solving a system of linear equations with different configuration setting of the RO gives delay of an individual gate. Experimental results from a test chip in 65nm process node show the feasibility of measuring the delay of an individual inverter to within 1pS accuracy. Delay measurements of different nominally identical inverters in close physical proximity show variations of up to 26% indicating the large impact of local or within-die variations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports a new class of photo-cross-linkable side chain liquid crystalline polymers (PSCLCPs) based on the bis(benzylidene)cyclohexanone unit, which functions as both a mesogen and a photoactive center. Polymers with the bis(benzylidene)cyclohexanone unit and varying spacer length have been synthesized. Copolymers of bis(benzylidene)cyclohexanone containing monomer and cholesterol benzoate containing monomer with different compositions have also been prepared. All these polymers have been structurally characterized by spectroscopic techniques. Thermal transitions were studied by DSC, and mesophases were identified by polarized light optical microscopy (POM). The intermediate compounds OH-x, the monomers SCLCM-x, and the corresponding polymers PSCLCP-x, which are essentially based on bis(benzylidene)cyclohexanone, all show a nematic mesophase. Transition temperatures were observed to decrease with increasing spacer length. The copolymers with varying compositions exhibit a cholesteric mesophase, and the transition temperatures increase with the cholesteric benzoate units in the copolymer. Photolysis of the low molecular weight liquid crystalline bis(benzylidene)-cyclohexanone compound reveals that there are two kinds of photoreactions in these systems: the EZ photoisomerization and 2 pi + 2 pi addition. The EZ photoisomerization in the LC phase disrupts the parallel stacking of the mesogens, resulting in the transition from the LC phase to the isotropic phase. The photoreaction involving the 2 pi + 2 pi addition of the bis(benzylidene)cyclohexanone units in the polymer results in the cross-linking of the chains. The liquid crystalline induced circular dichroism (LCICD) studies of the cholesterol benzoate copolymers revealed that the cholesteric supramolecular order remains even after the photo-cross-linking.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neutron diffraction measurement is carried out on GexSe1-x glasses, where 0.1 less than or equal to x less than or equal to 0.4, in a Q interval of 0.55-13.8 Angstrom(-1). The first sharp diffraction peak (FSDP) in the structure factor, S(Q), shows a systematic increase in the intensity and shifts to a lower Q with increasing Ge concentration. The coherence length of FSDP increases with x and becomes maximum for 0.33 less than or equal to x less than or equal to 0.4. The Monte-Carlo method, due to Soper, is used to generate S(Q) and also the pair correlation function, g(r). The generated S(Q) is in agreement with the experimental data for all x. Analysis of the first four peaks in the total correlation function, T(r), shows that the short range order in GeSe2 glass is due to Ge(Se-1/2)(4) tetrahedra, in agreement with earlier reports. Se-rich glasses contain Se-chains which are cross-linked with Ge(Se-1/2)(4) tetrahedra. Ge-2(Se-1/2)(6) molecular units are the basic structural units in Ge-rich, x = 0.4, glass. For x = 0.2, 0.33 and 0.4 there is evidence for some of the tetrahedra being in an edge-shared configuration. The number of edge-shared tetrahedra in these glasses increase with increasing Ge content.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The measurement of surface energy balance over a land surface in an open area in Bangalore is reported. Measurements of all variables needed to calculate the surface energy balance on time scales longer than a week are made. Components of radiative fluxes are measured while sensible and latent heat fluxes are based on the bulk method using measurements made at two levels on a micrometeorological tower of 10 m height. The bulk flux formulation is verified by comparing its fluxes with direct fluxes using sonic anemometer data sampled at 10 Hz. Soil temperature is measured at 4 depths. Data have been continuously collected for over 6 months covering pre-monsoon and monsoon periods during the year 2006. The study first addresses the issue of getting the fluxes accurately. It is shown that water vapour measurements are the most crucial. A bias of 0.25% in relative humidity, which is well above the normal accuracy assumed the manufacturers but achievable in the field using a combination of laboratory calibration and field intercomparisons, results in about 20 W m(-2) change in the latent heat flux on the seasonal time scale. When seen on the seasonal time scale, the net longwave radiation is the largest energy loss term at the experimental site. The seasonal variation in the energy sink term is small compared to that in the energy source term.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We demonstrate that the hyper-Rayleigh scattering technique can be employed to measure the partition coefficient (k(p)) of a solute in a mixture of two immiscible solvents. Specifically, partition coefficients of six substituted benzoic acids in water/toluene (1:1 v/v) and water/chloroform (1:1 v/v) systems have been measured. Our values compare well with the k(p) values measured earlier by other techniques, The advantages offered by this technique are also discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a technique for an all-digital on-chip delay measurement system to measure the skews in a clock distribution network. It uses the principle of sub-sampling. Measurements from a prototype fabricated in a 65 nm industrial process, indicate the ability to measure delays with a resolution of 0.5ps and a DNL of 1.2 ps.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An inexpensive and simple circuit to aid the direct measurement of majority carrier capture cross sections of impurity levels in the band gap of a semiconductor by the variable width filling pulse technique is presented. With proper synchronisation, during the period of application of the pulse, the device is disconnected from the capacitance meter to avoid distortion of the pulse and is reconnected again to the meter to record the emission transient. Modes of operation include manual triggering for long emission transients, repetitive triggering for isothermal and DLTS measurements and the DLTS mode which is to be used with signal analysers that already provide a synchronising pulse for disconnection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The minimum cost classifier when general cost functionsare associated with the tasks of feature measurement and classification is formulated as a decision graph which does not reject class labels at intermediate stages. Noting its complexities, a heuristic procedure to simplify this scheme to a binary decision tree is presented. The optimizationof the binary tree in this context is carried out using ynamicprogramming. This technique is applied to the voiced-unvoiced-silence classification in speech processing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the design and characterization of a circuit technique to measure the on-chip delay of an individual logic gate (both inverting and noninverting) in its unmodified form. The test circuit comprises of digitally reconfigurable ring oscillator (RO). The gate under test is embedded in each stage of the ring oscillator. A system of linear equations is then formed with different configuration settings of the RO, relating the individual gate delay to the measured period of the RO, whose solution gives the delay of the individual gates. Experimental results from a test chip in 65-nm process node show the feasibility of measuring the delay of an individual inverter to within 1 ps accuracy. Delay measurements of different nominally identicall inverters in close physical proximity show variations of up to 28% indicating the large impact of local variations. As a demonstration of this technique, we have studied delay variation with poly-pitch, length of diffusion (LOD) and different orientations of layout in silicon. The proposed technique is quite suitable for early process characterization, monitoring mature process in manufacturing and correlating model-to-hardware.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A modified DLTS technique is proposed for the direct measurement of capture cross-section of MOS surface states. The nature of temperature and energy dependence σn is inferred from data analysis. Temperature dependence of σn is shown to be consistent with the observed DLTS line shapes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

his paper describes an improved microtiter solid-phase enzyme immunoassay for the determination of total and allergen-specific human IgE. This assay technique is unique in its use of the avidin-biotin interaction to increase sensitivity. The avidin-biotin microtiter enzyme-linked immunosorbant assay (AB-microELISA) was performed in polyvinyl chloride microtiter plates using biotinylated anti-IgE and horseradish peroxidase (HRP)-avidin conjugate. This AB-microELISA technique enabled the quantitation of human serum IgE in the range of 0.1–5 ng/ml (10–500 pg/test) in less than 3 h. Total serum IgE, whether measured by the AB-microELISA or the paper radioimmunosorbant test (PRIST) was similar (correlation coefficient, r = 0.92). Further, the presence or absence of positive skin tests to 7 specific allergens determined in serum donors generally agreed with the presence or absence of allergen-specific IgE in their sera as measured by the AB-microELISA. The quantity of short ragweed allergen-specific IgE as determined by the AB-microELISA agreed with values obtained by the radioimmunosorbant test (RAST) (correlation coefficient, r = 0.89). No significant interference by ragweed-specific IgG (blocking antibody) was observed in the quantitation of allergen-specific IgE. The AB-microELISA is not only rapid and inexpensive, but also more sensitive than other published ELISA procedures and comparable to solid-phase radioimmunoassays in the quantitation of total and allergen-specific IgE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Interfacial area measurement has been carried out experimentally by measuring the bubble size and holdup for air-sodium chloride solution system. The size of the bubble is predominantly established by the air hold up. High speed photography technique for bubble size measurement and gamma ray attenuation method for holdup measurements are followed. The measured values are compared with the theoretically predicted values. Interracial area as a function of the liquid flow rate and also its distance from the nozzle of the ejector has been reported in this paper. The results obtained for this non-reactive system are also compared with those of air-water system.