16 resultados para Measuring intangible assets

em Indian Institute of Science - Bangalore - Índia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Here, we describe a novel FBG interrogation system in which FBGs are used as both sensing and reference elements. The reference FBGs is bonded to a mechanical flexure system having a linear amplification of 1:3.5, which is actuated using a piezo-actuator by applying a 0-150V ramp. The lengths of the reference gratings decide the maximum strain that can be applied to the reference grating, which in turn decides that strain range which can be interrogated. The main advantages of the present system are the on-line measurement of the wavelength shifts, small size, good sensitivity, multiplexing capability and low cost.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The transmission-line or the impedance-tube method for the measurement of the acoustic impedance of any termination involves a search for various minima and maxima of pressure. For this purpose, arrangement has to be made for the microphone to travel along the length of the impedance tube, and this complicates the design of the tube considerably. The present paper discusses a method which consists in evaluating the tube attenuation factor at any convenient frequency by making use of measured SPL's at two (or more) fixed locations with a rigid termination, calculating the tube attenuation factor and wave number at the required frequency of interest with or without mean flow (as applicable), and finally evaluating the impedance of the given termination by measuring and using SPL's at three (or more) fixed locations. Thus, the required impedance tube is considerably smaller in length, simpler in design, easier to manufacture, cheaper in cost and more convenient to use. The design of the tube is also discussed. Incidentally, it is also possible to evaluate the impedance at any low frequency without having to use a larger impedance tube.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Separated local field (SLF) spectroscopy is a powerful technique to measure heteronuclear dipolar couplings. The method provides site-specific dipolar couplings for oriented samples such as membrane proteins oriented in lipid bilayers and liquid crystals. A majority of the SLF techniques utilize the well-known Polarization Inversion Spin Exchange at Magic Angle (PISEMA) pulse scheme which employs spin exchange at the magic angle under Hartmann-Hahn match. Though PISEMA provides a relatively large scaling factor for the heteronuclear dipolar coupling and a better resolution along the dipolar dimension, it has a few shortcomings. One of the major problems with PISEMA is that the sequence is very much sensitive to proton carrier offset and the measured dipolar coupling changes dramatically with the change in the carrier frequency. The study presented here focuses on modified PISEMA sequences which are relatively insensitive to proton offsets over a large range. In the proposed sequences, the proton magnetization is cycled through two quadrants while the effective field is cycled through either two or four quadrants. The modified sequences have been named as 2(n)-SEMA where n represents the number of quadrants the effective field is cycled through. Experiments carried out on a liquid crystal and a single crystal of a model peptide demonstrate the usefulness of the modified sequences. A systematic study under various offsets and Hartmann-Hahn mismatch conditions has been carried out and the performance is compared with PISEMA under similar conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple technique for the measurement of the beam shape parameters of pulsed lasers, with just a single pulse of the laser is described. It involves the use of several beam dividers inclined at very small angles to the beam axis, reflecting the beam back to a screen or a phosphor placed near the exit of the laser. The reflected images are then photographed by a camera to yield the beam parameters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A sensitive and rapid bioassay of inhibin is described. Swiss albino female mice, 27 days old, weighing 25-30 g, were primed with 20 IU hCG, given in 2 equal doses, administered at 0900 h and 1800 h. An increment of 200% in uterine weight could be observed when the animals were autopsied the next day at 1000 h. The validity of the endpoint chosen, as a function dependent on FSH, was shown by the fact that neutralization of endogenous FSH by FSH antiserum led to an inhibition of uterine weight increase. Further injection of the inhibin material caused an actual reduction in the heightened levels of FSH (ng/ml) brought about by hCG: Control, 207 ± 13.6; hCG, 365 ± 28.8 and hCG inhibin, below the detection level of radioimmunoassay. Inhibin preparation from ovine testicular extract when tested at 3 dose levels showed a dose dependent and significant suppression in uterine weight increase. The assay was statistically validε = 2.5; slope = 23.9; λ = 0.104 and intra- and interassay variation = 8.3% and 11.7%, respectively. Since the mouse uterine weight assay is specific, has greater sensitivity and is uniformly reproducible, it is suggested that this assay procedure is ideally suited to assess the activity of different inhibin test preparations as well as to follow the purification of inhibin activity from crude material.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of a radioreceptor assay (RRA) that can measure serum LH in a variety of species and CG in sera and urine of pregnant women and monkeys is reported. Using sheep luteal membrane as the receptor source and I-125-labelled hLH/hCG as the tracer, dose-response (displacement) curves were obtained using hLH or hCG as standard. The addition of LH-free serum (200 mul per tube) had no affect on the standard displacement curve. The assay is simple, requires less than 90 min to complete and provides reproducible results. The sensitivity of the assay was 0.6 ng hLH per tube and the intra- and interassay variations were 9.6 and 9.8, respectively. Sera obtained from male and female bonnet monkeys (Macaca radiata) and monkey pituitary extract showed parallelism to the standard curve. The concentrations of LH measured correlated with the physiological status of the animals. Sera of rats, rabbits, hamsters, guinea-pigs, sheep and humans showed parallelism to the hLH standard curve indicating the viability of the RRA to measure serum LH of different species. Since the receptors recognize LH and CG, detection of pregnancy in monkeys and women was possible using this assay. The sensitivity of the assay for hCG was 8.7 miu per tube. This RRA could be a convenient alternative to the Leydig cell bioassay for obtaining the LH bioactivity profile of sera and biological fluids.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multisensor recordings are becoming commonplace. When studying functional connectivity between different brain areas using such recordings, one defines regions of interest, and each region of interest is often characterized by a set (block) of time series. Presently, for two such regions, the interdependence is typically computed by estimating the ordinary coherence for each pair of individual time series and then summing or averaging the results over all such pairs of channels (one from block 1 and other from block 2). The aim of this paper is to generalize the concept of coherence so that it can be computed for two blocks of non-overlapping time series. This quantity, called block coherence, is first shown mathematically to have properties similar to that of ordinary coherence, and then applied to analyze local field potential recordings from a monkey performing a visuomotor task. It is found that an increase in block coherence between the channels from V4 region and the channels from prefrontal region in beta band leads to a decrease in response time.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Different types of Large Carbon Cluster (LCC) layers are synthesized by a single-step pyrolysis technique at various ratios of precursor mixture. The aim is to develop a fast responsive and stable thermal gauge based on a LCC layer which has relatively good electrical conduction in order to use it in the hypersonic flow field. The thermoelectric property of the LCC layer has been studied. It is found that these carbon clusters are sensitive to temperature changes. Therefore suitable thermal gauges were developed for blunt cone bodies and were tested in hypersonic shock tunnels at a flow Mach number of 6.8 to measure aerodynamic heating. The LCC layer of this thermal gauge encounters high shear forces and a hostile environment for test duration in the range of a millisecond. The results are favorable to use large carbon clusters as a better sensor than a conventional platinum thin film gauge in view of fast responsiveness and stability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Redox signaling plays a crucial role in the pathogenesis of human immunodeficiency virus type-1 (HIV-1). The majority of HIV redox research relies on measuring redox stress using invasive technologies, which are unreliable and do not provide information about the contributions of subcellular compartments. A major technological leap emerges from the development of genetically encoded redox-sensitive green fluorescent proteins (roGFPs), which provide sensitive and compartment-specific insights into redox homeostasis. Here, we exploited a roGFP-based specific bioprobe of glutathione redox potential (E-GSH; Grx1-roGFP2) and measured subcellular changes in E-GSH during various phases of HIV-1 infection using U1 monocytic cells (latently infected U937 cells with HIV-1). We show that although U937 and U1 cells demonstrate significantly reduced cytosolic and mitochondrial E-GSH (approximately -310 mV), active viral replication induces substantial oxidative stress (E-GSH more than -240 mV). Furthermore, exposure to a physiologically relevant oxidant, hydrogen peroxide (H2O2), induces significant deviations in subcellular E-GSH between U937 and U1, which distinctly modulates susceptibility to apoptosis. Using Grx1-roGFP2, we demonstrate that a marginal increase of about similar to 25 mV in E-GSH is sufficient to switch HIV-1 from latency to reactivation, raising the possibility of purging HIV-1 by redox modulators without triggering detrimental changes in cellular physiology. Importantly, we show that bioactive lipids synthesized by clinical drug-resistant isolates of Mycobacterium tuberculosis reactivate HIV-1 through modulation of intracellular E-GSH. Finally, the expression analysis of U1 and patient peripheral blood mononuclear cells demonstrated a major recalibration of cellular redox homeostatic pathways during persistence and active replication of HIV.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We demonstrate a straightforward technique to measure the linewidth of a grating-stabilized diode laser system - known as an external cavity diode laser (ECDL) - by beating the output of two independent ECDLs in a Michelson interferometer, and then taking the Fourier transform of the beat signal. The measured linewidth is the sum of the linewidths of the two laser systems. Assuming that the two are equal, we find that the linewidth of each ECDL measured over a time period of 2. s is about 0.3 MHz. This narrow linewidth shows the advantage of using such systems for high-resolution spectroscopy and other experiments in atomic physics.