13 resultados para Measurement Techniques, Fibreoptic
em Indian Institute of Science - Bangalore - Índia
Resumo:
Cationic surfactants such as dodecyltrimethylammonium bromide (DTAB), tetradecyltrimehtylammonium bromide (TTAB) and hexadecyltrimethylammonium bromide (HTAB); and anionic surfactants such as sodium decyl sulphate (SDeS), sodium dodecyl sulphate (SDS) and sodium tetradecyl sulphate (STDS) have been used to determine their solubility and micellization in ternary eutectic melt (acetamide + urea + ammonium nitrate) at 50 degrees C. We employed the electrical conductivity and the surface tension measurement techniques to determine the critical micelle concentration (CMC). The deviation in the slope of the specific conductance/surface tension against surfactant concentration plots indicated the aggregations of surfactants and hence, their CMC. CMC decreases with increase of alkyl chain length due to the increased van der Waals forces. The calculated increment in Gibb's energy per methylene group for cationic and anionic surfactants is about -6 kJ mol(-1) and -4 kJ mol(-1) respectively. It is found that, the CMCs of the surfactants in the ternary melt are higher than the CMCs of same surfactants in water (similar to 25 degrees C). (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
The characteristics of surface roughness span a range of length scales determined by the nature of the surface generation process. The mechanism by which material is removed at a length scale determines the roughness at that scale. Electropolishing preferentially reduces the peaks of surface protuberances at sub-micron length scales to produce smooth surfaces. The material removal in electropolishing occurs by two different mechanisms of anodic leveling and microsmoothing. Due to insufficient lateral resolution, individual contribution of these two mechanisms could not be measured by conventional roughness measurement techniques and parameters. In this work, we utilize the high lateral resolution offered by Atomic force microscopy along with the power spectral density method of characterization, to study the evolution of roughness during electropolishing. The power spectral density show two corner frequencies indicating the length scales over which the two mechanisms operate. These characteristic frequencies are found to be a function of the electropolishing time and hence can be used to optimize the electropolishing process.
Resumo:
Hexaazamacrocycle (L) stabilized gold nanoparticles (AuNPs) were prepared by combining L with HAuCl4 center dot 3H(2)O in a variety of alcohol-water (1 : 1) mixtures. The dual roles of L as a reducing and stabilizing agent were exploited for the synthesis of AuNPs under the optimized ratio of L to Au3+ (2 : 1). Self-assembled gold nanofilms (AuNFs) were constructed at liquid-liquid interfaces by adding equal volumes of hexane to the dispersions of AuNPs in the alcohol-water systems. The nanofilms were formed spontaneously by shaking the two-phase mixture for a minute followed by standing. The alcohols explored for the self-assembly phenomenon were methanol, ethanol, i-propanol and t-butanol. The systems containing methanol or t-butanol resulted in AuNFs at the interfaces, whereas the other two alcohols were found not suitable and the AuNPs remained dispersed in the corresponding alcohol-water medium. The AuNFs prepared under suitable conditions were coated on a variety of surfaces by the dip and lift-off method/solvent removal approach. The AuNFs were characterized by UV-vis, SEM, TEM, AFM and contact angle measurement techniques. A coated glass-vial or cuvette was used as a catalytic reservoir for nitro-reduction reactions under ambient and aqueous conditions using NaBH4 as the reducing agent. The reduced products (amines) were extracted by aqueous work-up using ethyl acetate followed by evaporation of the organic layer; the isolated products required no further purification. The catalyst was recovered by simply decanting the reaction mixture whereupon the isolated catalyst remained coated inside the vessel. The recovered catalyst was found to be equally efficient for further catalytic cycles.
Resumo:
We demonstrate that the hyper-Rayleigh scattering technique can be employed to measure the partition coefficient (k(p)) of a solute in a mixture of two immiscible solvents. Specifically, partition coefficients of six substituted benzoic acids in water/toluene (1:1 v/v) and water/chloroform (1:1 v/v) systems have been measured. Our values compare well with the k(p) values measured earlier by other techniques, The advantages offered by this technique are also discussed.
Resumo:
The heat capacity of a substance is related to the structure and constitution of the material and its measurement is a standard technique of physical investigation. In this review, the classical methods are first analyzed briefly and their recent extensions are summarized. The merits and demerits of these methods are pointed out. The newer techniques such as the a.c. method, the relaxation method, the pulse methods, the laser flash calorimetry and other methods developed to extend the heat capacity measurements to newer classes of materials and to extreme conditions of sample geometry, pressure and temperature are comprehensively reviewed. Examples of recent work and details of the experimental systems are provided for each method. The introduction of automation in control systems for the monitoring of the experiments and for data processing is also discussed. Two hundred and eight references and 18 figures are used to illustrate the various techniques.
Resumo:
An investigation of the problem of controlled doping of amorphous chalcogenide semiconductors utilizing a Bridgman anvil high pressure technique, has been undertaken. Bulk amorphous semiconducting materials (GeSe3.5)100-x doped with M = Bi (x = 2, 4, 10) and M = Sb (x = 10) respectively are studied up to a pressure of 100 kbar down to liquid nitrogen temperature, with a view to observe the impurity induced modifications. Measurement of the electrical conductivity of the doped samples under quasi-hydrostatic pressure reveals that the pressure induced effects in lightly doped (2 at % Bi) and heavily doped (x = 4, 10) semiconductors are markedly different. The pressure effects in Sb-doped semiconductors are quite different from those in Bi-doped material.
Ultrasonic measurement of the elastic constants of sodium p-nitrophenolate dihydrate single crystals
Resumo:
Sodium p-nitrophenolate dihydrate single crystals possess excellent nonlinear optical properties such that they can be used for optical second-harmonic generation. It belongs to the orthorhombic system with the space group Ima2. Slow evaporation or slow cooling techniques can be used to grow good optical quality single crystals from supersaturated solution. All the nine elastic constants of this crystal have been measured using an ultrasonic technique. Samples for measurements have been cut along desired crystallographic axes and the pulse echo overlap technique has been used to measure longitudinal and shear ultrasonic wave velocities along appropriate symmetry directions in the crystal. The McSkimin Delta t criterion has been applied to determine the round trip travel time accurately, from which the nine elastic constants have been evaluated. Temperature variation of selected elastic constants in a limited range have also been measured and reported.
Resumo:
Digital Image Correlation and Tracking (DIC/DDIT) is an optical method that employs tracking & image registration techniques for accurate 2D and 3D measurements of changes in images. This is often used to measure deformation (engineering), displacement, and strain, but it is widely applied in many areas of science and engineering. One very common application is for measuring the motion of an optical mouse.
Resumo:
The use of long-range heteronuclear couplings, in association with 1H1H scalar couplings and NOE restraints, has acquired growing importance for the determination of the relative stereochemistry, and structural and conformational information of organic and biological molecules. However, the routine use of such couplings is hindered by the inherent difficulties in their measurement. Prior to the advancement in experimental techniques, both long-range homo- and heteronuclear scalar couplings were not easily accessible, especially for very large molecules. The development of a large number of multidimensional NMR experimental methodologies has alleviated the complications associated with the measurement of couplings of smaller strengths. Subsequent application of these methods and the utilization of determined J-couplings for structure calculations have revolutionized this area of research. Problems in organic, inorganic and biophysical chemistry have also been solved by utilizing the short- and long-range heteronuclear couplings. In this minireview, we discuss the advantages and limitations of a number of experimental techniques reported in recent times for the measurement of long-range heteronuclear couplings and a few selected applications of such couplings. This includes the study of medium- to larger-sized molecules in a variety of applications, especially in the study of hydrogen bonding in biological systems. The utilization of these couplings in conjunction with theoretical calculations to arrive at conclusions on the hyperconjugation, configurational analysis and the effect of the electronegativity of the substituents is also discussed.
Resumo:
This paper considers the problem of identifying the footprints of communication of multiple transmitters in a given geographical area. To do this, a number of sensors are deployed at arbitrary but known locations in the area, and their individual decisions regarding the presence or absence of the transmitters' signal are combined at a fusion center to reconstruct the spatial spectral usage map. One straightforward scheme to construct this map is to query each of the sensors and cluster the sensors that detect the primary's signal. However, using the fact that a typical transmitter footprint map is a sparse image, two novel compressive sensing based schemes are proposed, which require significantly fewer number of transmissions compared to the querying scheme. A key feature of the proposed schemes is that the measurement matrix is constructed from a pseudo-random binary phase shift applied to the decision of each sensor prior to transmission. The measurement matrix is thus a binary ensemble which satisfies the restricted isometry property. The number of measurements needed for accurate footprint reconstruction is determined using compressive sampling theory. The three schemes are compared through simulations in terms of a performance measure that quantifies the accuracy of the reconstructed spatial spectral usage map. It is found that the proposed sparse reconstruction technique-based schemes significantly outperform the round-robin scheme.
Resumo:
In the present work, we report a novel, in vivo, noninvasive technique to determine radial arterial compliance using the radial arterial pressure pulse waveform (RAPPW) acquired by fiber Bragg grating pulse recorder (FBGPR). The radial arterial compliance of the subject can be measured during sphygmomanometric examination by the unique signatures of arterial diametrical variations and the beat-to-beat pulse pressure acquired simultaneously from the RAPPW recorded using FBGPR. This proposed technique has been validated against the radial arterial diametrical measurements obtained from the color Doppler ultrasound. Two distinct trials have been illustrated in this work and the results from both techniques have been found to be in good agreement with each other.
Resumo:
Disease conditions like malaria, sickle cell anemia, diabetes mellitus, cancer, etc., are known to significantly alter the deformability of certain types of cells (red blood cells, white blood cells, circulating tumor cells, etc.). To determine the cellular deformability, techniques like micropipette aspiration, atomic force microscopy, optical tweezers, quantitative phase imaging have been developed. Many of these techniques have an advantage of determining the single cell deformability with ultrahigh precision. However, the suitability of these techniques for the realization of a deformability based diagnostic tool is questionable as they are expensive and extremely slow to operate on a huge population of cells. In this paper, we propose a technique for high-throughput (800 cells/s) determination of cellular deformability on a single cell basis. This technique involves capturing the image(s) of cells in flow that have undergone deformation under the influence of shear gradient generated by the fluid flowing through the microfluidic channels. Deformability indices of these cells can be computed by performing morphological operations on these images. We demonstrate the applicability of this technique for examining the deformability index on healthy, diabetic, and sphered red blood cells. We believe that this technique has a strong role to play in the realization of a potential tool that uses deformability as one of the important criteria in disease diagnosis.
Resumo:
Purpose: Reverse iontophoresis (RI) is one of the potential techniques used to monitor the concentration of various analytes in body fluids non -invasively. Transdermal extraction of potassium is investigated using RI. In the present work, the effect of potassium on stratum corneum (SC) during RI, feasibility of RI for continuous monitoring of potassium, and use of potassium as internal standard in RI, are investigated. Methods: Tape stripping experiment is carried out to find potassium concentration in SC. RI is carried out continuously for 180 min without passive diffusion and after passive diffusion for 60 min. Skin impedance measurements are done at 20 Hz and 20 kHz. Results: Potassium is found to be in the range 300-650 nmol/cm(2) on SC by tape stripping experiment. Correlation coefficient between blood potassium and extracted potassium through RI after passive diffusion (R-2 = 0.5870) is more than without passive diffusion (R-2 = 0.5117). The skin impedance measurement shows that RI has more effect on SC than superficial layer of SC during RI. Conclusion: The present investigations conclude that it is possible to monitor potassium continuously through RI and using potassium as internal standard in RI.