6 resultados para MICROFLUIDIC SYSTEMS

em Indian Institute of Science - Bangalore - Índia


Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper critically analyzes, for the first time, the effect of nanofluid on thermally fully developed magnetohydrodynamic flows through microchannel, by considering combined effects of externally applied pressure gradient and electroosmosis. The classical boundary condition of uniform wall heat flux is considered, and the effects of viscous dissipation as well as Joule heating have been taken into account. Closed-form analytical expressions for the pertinent velocity and temperature distributions and the Nusselt number variations are obtained, in order to examine the role of nanofluids in influencing the fully developed thermal transport in electroosmotic microflows under the effect of magnetic field. Fundamental considerations are invoked to ascertain the consequences of particle agglomeration on the thermophysical properties of the nanofluid. The present theoretical formalism addresses the details of the interparticle interaction kinetics in tune with the pertinent variations in the effective particulate dimensions, volume fractions of the nanoparticles, as well as the aggregate structure of the particulate system. It is revealed that the inclusion of nanofluid changes the transport characteristics and system irreversibility to a considerable extent and can have significant consequences in the design of electroosmotically actuated microfluidic systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Traditional methods of detecting chiral molecules, such as optical rotation are not suitable for miniaturization, since, the magnitude of the rotation of polarization scales down linearly with the optical path length of the device. Since the origin of optical activity is due to difference of refractive indices between the two circularly polarized states of light, it is possible to detect chiral media by measuring the dependence of the angles of refraction on the polarization state of the incident light. This however is a weak effect and hence requires sensitive optical detection schemes, based on novel polarization modulation techniques. The device can be scaled down for applications involving small sample volumes. Fabrication details of a prototype microfluidic device are described.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Several concepts have been developed in the recent years for nanomaterial based integrated MEMS platform in order to accelerate the process of biological sample preparation followed by selective screening and identification of target molecules. In this context, there exist several challenges which need to be addressed in the process of electrical lysis of biological cells. These are due to (i) low resource settings while achieving maximal lysis (ii) high throughput of target molecules to be detected (iii) automated extraction and purification of relevant molecules such as DNA and protein from extremely small volume of sample (iv) requirement of fast, accurate and yet scalable methods (v) multifunctionality toward process monitoring and (vi) downward compatibility with already existing diagnostic protocols. This paper reports on the optimization of electrical lysis process based on various different nanocomposite coated electrodes placed in a microfluidic channel. The nanocomposites are synthesized using different nanomaterials like Zinc nanorod dispersion in polymer. The efficiency of electrical lysis with various different electrode coatings has been experimentally verified in terms of DNA concentration, amplification and protein yield. The influence of the coating thickness on the injection current densities has been analyzed. We further correlate experimentally the current density vs. voltage relationship with the extent of bacterial cell lysis. A coupled multiphysics based simulation model is used to predict the cell trajectories and lysis efficiencies under various electrode boundary conditions as estimated from experimental results. Detailed in-situ fluorescence imaging and spectroscopy studies are performed to validate various hypotheses.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A simple method to study the air bubble dynamics and to burst the air bubbles formed on the electrode– electrolyte interface in a parallel gate electrode fluidic channel is demonstrated. Upon application of a voltage across the electrodes,volume of water contained between them begins to electrolyzing depending on the conductivity, as well as it boils due to heating effect. This results in bubble formation within. These bubbles grow in radius with higher potential difference applied across the electrodes. As an approach towards removing these bubbles, an alternating current is applied at low potential difference of a 5 volts and high frequency at few megahertz. The alternating electric field had a heating effect on the bubbles where the energy input due to current heats up water and bursts the bubble. The bubbles of size up to 480μm were burst at 2500 V/m using this approach.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Microfluidic/optofluidic microscopy is a versatile modality for imaging and analyzing properties of cells/particles while they are in flow. In this paper, we demonstrate the integration of fused silica microfluidics fabricated using femtosecond laser machining into optofluidic imaging systems. By using glass for the sample stage of our microscope, we have exploited its superior optical quality for imaging and bio-compatibility. By integrating these glass microfluidic devices into a custom-built bright field microscope, we have been able to image red blood cells in flow with high-throughputs and good fidelity. In addition, we also demonstrate imaging as well as detection of fluorescent beads with these microfluidic devices.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this article, we present a novel approach to throughput enhancement in miniaturized microfluidic microscopy systems. Using the presented approach, we demonstrate an inexpensive yet high-throughput analytical instrument. Using the high-throughput analytical instrument, we have been able to achieve about 125,880 cells per minute (more than one hundred and twenty five thousand cells per minute), even while employing cost-effective low frame rate cameras (120 fps). The throughput achieved here is a notable progression in the field of diagnostics as it enables rapid quantitative testing and analysis. We demonstrate the applicability of the instrument to point-of-care diagnostics, by performing blood cell counting. We report a comparative analysis between the counts (in cells per mu l) obtained from our instrument, with that of a commercially available hematology analyzer.