20 resultados para MEASURE

em Indian Institute of Science - Bangalore - Índia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pentacyclic ketones 10a-e (snoutan-9-ones) undergo nucleophilic additions with the same facial preference as the corresponding norsnoutanones 9a-e, but with markedly reduced selectivity, revealing the involvement of electrostatic effects in the former and implying the importance of hyperconjugative orbital interactions in determining pi-face selectivity in the latter systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The research in software science has so far been concentrated on three measures of program complexity: (a) software effort; (b) cyclomatic complexity; and (c) program knots. In this paper we propose a measure of the logical complexity of programs in terms of the variable dependency of sequence of computations, inductive effort in writing loops and complexity of data structures. The proposed complexity mensure is described with the aid of a graph which exhibits diagrammatically the dependence of a computation at a node upon the computation of other (earlier) nodes. Complexity measures of several example programs have been computed and the related issues have been discussed. The paper also describes the role played by data structures in deciding the program complexity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Measurement of receptor-bound unlabelled physiologically active lutropin (luteinizing hormone, LH) was possible by a modified radioimmunoassay. The conventional radioimmunoassayconducted at 4°C was inadequate, whereas the modified assay performed at 37'C could measure receptor-bound lutropin. The radioimmunoassay at 37'C takes only 36h for completion compared with 5-7 days at 4°C. The sensitivity and range of dose-response curves are, however, unaltered. The validity of the technique was established by a number of criteria.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have developed a theory for an electrochemical way of measuring the statistical properties of a nonfractally rough electrode. We obtained the expression for the current transient on a rough electrode which shows three times regions: short and long time limits and the transition region between them. The expressions for these time ranges are exploited to extract morphological information about the surface roughness. In the short and long time regimes, we extract information regarding various morphological features like the roughness factor, average roughness, curvature, correlation length, dimensionality of roughness, and polynomial approximation for the correlation function. The formulas for the surface structure factors (the measure of surface roughness) of rough surfaces in terms of measured reversible and diffusion-limited current transients are also obtained. Finally, we explore the feasibility of making such measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new method based on analysis of a single diffraction pattern is proposed to measure deflections in micro-cantilever (MC) based sensor probes, achieving typical deflection resolutions of 1nm and surface stress changes of 50 mu N/m. The proposed method employs a double MC structure where the deflection of one of the micro-cantilevers relative to the other due to surface stress changes results in a linear shift of intensity maxima of the Fraunhofer diffraction pattern of the transilluminated MC. Measurement of such shifts in the intensity maxima of a particular order along the length of the structure can be done to an accuracy of 0.01mm leading to the proposed sensitivity of deflection measurement in a typical microcantilever. This method can overcome the fundamental measurement sensitivity limit set by diffraction and pointing stability of laser beam in the widely used Optical Beam Deflection method (OBDM).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Notched three point bend specimens (TPB) were tested under crack mouth opening displacement (CMOD) control at a rate of 0.0004 mm/s and during the fracture process acoustic emissions (AE) were simultaneously monitored. It was observed that AE energy could be related to fracture energy. An experimental study was done to understand the behavior of AE energy with parameters of concrete like its strength and size. In this study, AE energy was used as a quantitative measure of size independent specific fracture energy of concrete beams and the concepts of boundary effect and local fracture energy were used to obtain size independent AE energy from which size independent fracture energy was obtained. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The problem of quantification of intelligence of humans, and of intelligent systems, has been a challenging and controversial topic. IQ tests have been traditionally used to quantify human intelligence based on results of test designed by psychologists. It is in general very difficult to quantify intelligence. In this paper the authors consider a simple question-answering (Q-A) system and use this to quantify intelligence. The authors quantify intelligence as a vector with three components. The components consist of a measure of knowledge in asking questions, effectiveness of questions asked, and correctness of deduction. The authors formalize these parameters and have conducted experiments on humans to measure these parameters

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new approach based on occupation measures is introduced for studying stochastic differential games. For two-person zero-sum games, the existence of values and optimal strategies for both players is established for various payoff criteria. ForN-person games, the existence of equilibria in Markov strategies is established for various cases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Seizure electroencephalography (EEG) was recorded from two channels-right (Rt) and left (Lt)-during bilateral electroconvulsive therapy (ECT) (n = 12) and unilateral ECT (n = 12). The EEG was also acquired into a microcomputer and was analyzed without knowledge of the clinical details. EEG recordings of both ECT procedures yielded seizures of comparable duration. The Strength Symmetry Index (SSI) was computed from the early- and midseizure phases using the fractal dimension of the EEG. The seizures of unilateral ECT were characterized by significantly smaller SSI in both phases. More unilateral than bilateral ECT seizures had a smaller than median SSI in both phases. The seizures also differed on other measures as reported in the literature. The findings indicate that SSI may be a potential measure of seizure adequacy that remains to be validated in future research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The conventional definition of redundancy is applicable to skeletal structural systems only, whereas the concept of redundancy has never been discussed in the context of a continuum. Generally, structures in civil engineering constitute a combination of both skeletal and continuum segments. Hence, this gaper presents a generalized definition of redundancy that has been defined in terms of structural response sensitivity, which is applicable to both continuum and discrete structures. In contrast to the conventional definition of redundancy, which is assumed to be fixed for a given structure and is believed to be independent of loading and material properties, the new definition would depend on strength and response of the structure at a given stage of its service life. The redundancy measure proposed in this paper is linked to the structural response sensitivities. Thus, the structure can have different degrees of redundancy during its lifetime, depending on the response sensitivity under consideration It is believed that this new redundancy measure would be more relevant in structural evaluation, damage assessment, and reliability analysis of structures at large.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We introduce a multifield comparison measure for scalar fields that helps in studying relations between them. The comparison measure is insensitive to noise in the scalar fields and to noise in their gradients. Further, it can be computed robustly and efficiently. Results from the visual analysis of various data sets from climate science and combustion applications demonstrate the effective use of the measure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We introduce a novel temporal feature of a signal, namely extrema-based signal track length (ESTL) for the problem of speech segmentation. We show that ESTL measure is sensitive to both amplitude and frequency of the signal. The short-time ESTL (ST_ESTL) shows a promising way to capture the significant segments of speech signal, where the segments correspond to acoustic units of speech having distinct temporal waveforms. We compare ESTL based segmentation with ML and STM methods and find that it is as good as spectral feature based segmentation, but with lesser computational complexity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objects viewed through transparent sheets with residual non-parallelism and irregularity appear shifted and distorted. This distortion is measured in terms of angular and binocular deviation of an object viewed through the transparent sheet. The angular and binocular deviations introduced are particularly important in the context of aircraft windscreens and canopies as they can interfere with decision making of pilots especially while landing, leading to accidents. In this work, we have developed an instrument to measure both the angular and binocular deviations introduced by transparent sheets. This instrument is especially useful in the qualification of aircraft windscreens and canopies. It measures the deviation in the geometrical shadow cast by a periodic dot pattern trans-illuminated by the distorted light beam from the transparent test specimen compared to the reference pattern. Accurate quantification of the shift in the pattern is obtained by cross-correlating the reference shadow pattern with the specimen shadow pattern and measuring the location of the correlation peak. The developed instrument is handy to use and computes both angular and binocular deviation with an accuracy of less than +/- 0.1 mrad (approximate to 0.036 mrad) and has an excellent repeatability with an error of less than 2%. (C) 2012 American Institute of Physics. http://dx.doi.org/10.1063/1.4769756]