12 resultados para Heater, Chuck
em Indian Institute of Science - Bangalore - Índia
Resumo:
Since a majority of residential and industrial building hot water needs are around 50 degrees C, an integrated solar water heater could provide a bulk source that blends collection and storage into one unit. This paper describes the design, construction and performance test results of one such water-heating device. The test unit has an absorber area of 1.3 m(2) and can hold 1701 of water, of which extractable volume per day is 1001. Its performance was evaluated under various typical operating conditions. Every morning at about 7:00 a.m., 1001 of hot water were drawn from the sump and replaced with cold water from the mains. Although, during most of the days, the peak temperatures of water obtained are between 50 and 60 degrees C, the next morning temperatures were lower at 45-50 degrees C. Daytime collection efficiencies of about 60% and overall efficiencies of about 40% were obtained. Tests were conducted with and without stratification. Night radiation losses were reduced by use of a screen insulation.
Resumo:
A reduction in the heat losses from the top of the gas holder of a biogas plant has been achieved by the simple device of a transparent cover. The heat losses thus prevented have been deployed to heat a water pond formed on the roof of the gas holder. This solar-heated water is mixed with the organic input for ‘ hot-charging ’ of the biogas plant. A thermal analysis of such a solar water-heater ‘ piggy-backing ’ on the gas holder of a biogas plant has been carried out.To test whether the advantages indicated by the thermal analysis can be realised in practice, a biogas plant of the ASTRA design was modified to incorporate a roof-top solar water-heater. The operation of such a modified plant, even under ‘ worst case ’ onditions, shows a significant improvement in the gas yield compared to the unmodified plant. Hence, the innovation reported here may lead to drastic reductions in the sizes and therefore costs of biogas plants. By making the transparent cover assume a tent-shape, the roof-top solar heater can serve the additional function of a solar still to yield distilled water. The biogas plant-cum-solar water-heater-cum-solar still described here is an example of a spatially integrated hybrid device which is extremely cost-effective.
Resumo:
The design and implementation of a complete gas sensor system for liquified petroleum gas (LPG) gas sensing are presented. The system consists of a SnO2 transducer, a lowcost heater, an application specific integrated circuit (ASIC) with front-end interface circuitry, and a microcontroller interface for data logging. The ASIC includes a relaxation-oscillator-based heater driver circuit that is capable of controlling the sensor operating temperature from 100degC to 425degC. The sensor readout circuit in the ASIC, which is based on the resistance to time conversion technique, has been designed to measure the gas sensor response over three orders of resistance change during its interaction with gases.
Resumo:
We present a low power gas sensor system on CMOS platform consisting of micromachined polysilicon microheater, temperature controller circuit, resistance readout circuit and SnO2 transducer film. The design criteria for different building blocks of the system is elaborated The microheaters are optimized for temperature uniformity as well as static and dynamic response. The electrical equivalent model for the microheater is derived by extracting thermal and mechanical poles through extensive laser doppler vibrometer measurements. The temperature controller and readout circuit are realized on 130nm CMOS technology The temperature controller re-uses the heater as a temperature sensor and controls the duty cycle of the waveform driving the gate of the power MOSFET which supplies heater current. The readout circuit, with subthreshold operation of the MOSFETs, is based oil resistance to time period conversion followed by frequency to digital converter Subthreshold operatin of MOSFETs coupled with sub-ranging technique, achieves ultra low power consumption with more than five orders of magnitude dynamic range RF sputtered SnO2 film is optimized for its microstructure to achive high sensitivity to sense LPG gas.
Resumo:
An ammonia loop heat pipe (LHP) with a flat plate evaporator is developed and tested. The device uses a nickel wick encased in an aluminum-stainless steel casing. The loop is tested for various heat loads and different sink temperatures, and it demonstrated reliable startup characteristics. Results with the analysis of the experimental observation indicate that the conductance between the compensation chamber and the heater plate can significantly influence the operating temperatures of the LHP. A mathematical model is also presented which is validated against the experimental observations.
Resumo:
Three types of conventional solar air heater are designed such that their heat absorbing areas and the pressure drops across them are equal for equal air mass flow rates per unit collector area. The results of thermal performance tests conducted simultaneously on these collectors, under the same environmental conditions, are presented.
Resumo:
A microchip thermocycler, fabricated from silicon and Pyrex #7740 glass, is described. Usual resistive heating has been replaced by induction heating, leading to much simpler fabrication steps. Heating and cooling rates of 6.5 and 4.2 degreesC/s, respectively have been achieved, by optimising the heater dimensions and heating frequency (similar to200 kHz). Four devices are mounted on a heater, resulting in low power consumption (similar to 1.4 W per device on the average). Using simple on-off electronic temperature control, a temperature stability within -0.2 degreesC is achieved. Features such as induction heating, good temperature control, battery operation, and low power consumption make the device suitable for portable applications, particularly in polymerase chain reaction (PCR) systems. (C) 2002 Elsevier Science B.V. All rights reserved.
Resumo:
Three-dimensional numerical study of natural convection in a vertical channel with flush-mounted discrete heaters on opposite conductive substrate walls is carried out in the present work. Detailed flow and heat transfer characteristics are presented for various Grashof numbers. The heat transfer effects on one wall by the presence of heaters on its opposite wall is examined. It is found that heat transfer rates on one wall are increased by the presence of heaters on its opposite wall. The thermal boundary layers on the opposite walls complement each other for enhanced heat transfer. The effects of spacing between the heated walls, spacings between heaters and substrate conductivity on flow and heat transfer are examined. Existence of optimum spacings between the heated walls for maximum heat transfer and mass flow are observed. It is found that the heat transfer and fluid flow do not follow the same optimum spacings. Mass flow rate reaches maximum value at a wall spacing greater than the spacing for maximum heat transfer. This is because the interaction of thermal boundary layers on individual walls ceases at a lower spacing before the velocity boundary layers separate each other. It is found that increased spacings between heaters reduce individual heater temperatures provided the heaters close to exit on both substrates avail sufficient substrate potions on the exit side. Insufficient substrate portions between the exit heaters and the exit cause abnormal local temperature rise in the exit heaters which are the hottest ones among all the heaters. Optimal heater spacings exist for minimum hottest heater temperature rise. Correlations are presented for dimensionless mass flow rate, temperature maximum, and average Nusselt number.
Resumo:
Laminar natural convection in a series of thermally interacting cavities is numerically studied. Each cavity consists of a conducting bottom wall with a surface mounted heater. The side walls of the cavities are isothermally cooled. Each cavity thermally interacts with its adjacent cavities through the conducting walls. Flow and heat transfer characteristics are studied in detail for various Rayleigh numbers. The convection characteristics in multiple cavities are compared with those in single independent cavity. The thermal interaction between the cavities results in lower temperatures compared with those in independent cavities. While heat is rejected into the adjacent upper cavity through some portion of the conducting wall, heat is received from the adjacent cavity through the remaining portion of the wall. The influence of substrate conductivity on heat exchange between adjacent cavities are examined. Substrate conductivity shows strong effect on temperature distribution. When cooling at both vertical sides is changed to one side cooling, the heat transfer characteristics are changed drastically and many interesting flow features are observed. Effects of cavity aspect ratio is studied and higher heat transfer rates are observed at higher aspect ratios. Correlations for dimensionless temperature maximum and average Nusselt number are presented in terms of Rayleigh number.
Resumo:
Three-dimensional natural convection in a horizontal channel with an array of discrete flush-mounted heaters on one of its vertical walls is numerically studied. Effects of thermal conductivities of substrate and heaters and convection on outer sides of the channel walls on heat transfer are examined. The substrate affects heat transfer in a wider range of thermal conductivities than do the heaters. At lower heater thermal conductivities a higher heat portion is transferred by direct convection from the heaters to the adjacent coolant. However, higher substrate conductivity is associated with higher heat portion transferred through the substrate. The innermost heater column is found to become the hottest heater column due to the lower coolant accessibility. The heat transfer in the channel is strongly influenced by convection on the outer sides of the channel walls. Correlations are presented for dimensionless temperature maximum and average Nusselt number.
Resumo:
Detection of pathogens from infected biological samples through conventional process involves cell lysis and purification. The main objective of this work is to minimize the time and sample loss, as well as to increase the efficiency of detection of biomolecules. Electrical lysis of medical sample is performed in a closed microfluidic channel in a single integrated platform where the downstream analysis of the sample is possible. The device functions involve, in a sequence, flow of lysate from lysis chamber passed through a thermal denaturation counter where dsDNA is denatured to ssDNA, which is controlled by heater unit. A functionalized binding chamber of ssDNA is prepared by using ZnO nanorods as the matrix and functionalized with bifunctional carboxylic acid, 16-(2-pyridyldithiol) hexadecanoic acid (PDHA) which is further attached to a linker molecule 1-ethyl-3-(3-dimethylaminopropyl) (EDC). Linker moeity is then covalently bound to photoreactive protoporphyrin (PPP) molecule. The photolabile molecule protoporphyrin interacts with -NH2 labeled single stranded DNA (ssDNA) which thus acts as a probe to detect complimentary ssDNA from target organisms. Thereafter the bound DNA with protoporphyrin is exposed to an LED of particular wavelength for a definite period of time and DNA was eluted and analyzed. UV/Vis spectroscopic analysis at 260/280 nm wavelength confirms the purity and peak at 260 nm is reconfirmed for the elution of target DNA. Quantitative and qualitative data obtained from the current experiments show highly selective detection of biomolecule such as DNA which have large number of future applications in Point-of-Care devices.
Resumo:
This paper presents the development and testing of an integrated low-power and low-cost dual-probe heat-pulse (DPHP) soil-moisture sensor in view of the electrical power consumed and affordability in developing countries. A DPHP sensor has two probes: a heater and a temperature sensor probe spaced 3 mm apart from the heater probe. Supply voltage of 3.3V is given to the heater-coil having resistance of 33 Omega power consumption of 330 mW, which is among the lowest in this category of sensors. The heater probe is 40 mm long with 2 mm diameter and hence is stiff enough to be inserted into the soil. The parametric finite element simulation study was performed to ensure that the maximum temperature rise is between 1 degrees C and 5 degrees C for wet and dry soils, respectively. The discrepancy between the simulation and experiment is less than 3.2%. The sensor was validated with white clay and tested with red soil samples to detect volumetric water-content ranging from 0% to 30%. The sensor element is integrated with low-power electronics for amplifying the output from thermocouple sensor and TelosB mote for wireless communication. A 3.7V lithium ion battery with capacity of 1150 mAh is used to power the system. The battery is charged by a 6V and 300 mA solar cell array. Readings were taken in 30 min intervals. The life-time of DPHP sensor node is around 3.6 days. The sensor, encased in 30 mm x 20 mm x 10 mm sized box, and integrated with electronics was tested independently in two separate laboratories for validating as well as investigating the dependence of the measurement of soil-moisture on the density of the soil. The difference in the readings while repeating the experiments was found out to be less than 0.01%. Furthermore, the effect of ambient temperature on the measurement of soil-moisture is studied experimentally and computationally. (C) 2015 Elsevier B.V. All rights reserved.