3 resultados para Electromagnets

em Indian Institute of Science - Bangalore - Índia


Relevância:

10.00% 10.00%

Publicador:

Resumo:

ZLI-1167 is a ternary mixture of nematic liquid crystals with negative diamagnetic anisotropy. It has, therefore, been used as a solvent where the spinning of the samples around the vertical axis in the conventional electromagnets without destroying the orientation of the dissolved molecules is possible in NMR experiments. This results in sharp lines with widths up to 1 Hz in the spectra.1,2 In an NMR system using a superconducting magnet (where the magnetic field direction is along the axis of spinning of the sample), it is possible to use even the nematic liquid crystals with positive diamagnetic anisotropy such as N-(p'-methoxybenzylidene)-p-n-butylaniline (MBBA) or N-(p'-ethoxybenzylidene)-p-n-butylaniline (EBBA) to obtain the spectra with sample spinning with equally sharp lines.3 The orientational behaviour of the dissolved molecules as a function of relative concentrations of the two solvents is investigated and the results are reported in the present communication.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The optimisation is reported on the design of unbalanced magnetron (UBM) sputtering cathodes. For the study, a planar circular cathode backed by a double-coil electromagnet (compatible for a 100 mm diameter target) was developed. The variation of the structure and strength of the magnetic field in front of the target was investigated for different current combinations in the electromagnetic coils, and its effect on the sputtering process was analysed. The observations on the magnetic field geometry revealed some interesting features, such as the balancing point of the fields along the axis (null-point), and the zero axial region over the target surface (B-z = 0 ring). The positions of both could be controlled by adjusting the ratio of the electric current in the coils. The magnetic field null-point could be used as a reference for the region of homogeneous film growth. The B-z = 0 ring was the location where the glow discharge concentrated (or where the maximum target erosion occurred). The diameter of the ring determined the area covered by the discharge and thus the sputtering efficiency. The optimum substrate position can be fixed according to the position of the null-point and optimisation of sputtering can be achieved by adjusting the diameter of the B-z = 0 ring. The results of this study should be helpful in the designing of an ideal UBM using permanent magnets as well as electromagnets. (C) 1999 Elsevier Science Ltd. All rights reserved.