3 resultados para Dgs

em Indian Institute of Science - Bangalore - Índia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports a new design of microstrip directional coupler with high directivity. This directional coupler uses corrugated coupled lines and floating conductor in the ground plane of microstrip to enhance coupling. Based on this structure, directional coupler having 4.4% bandwidth has been designed at 4500 MHz with 10 dB coupling and 35 dB directivity. The designed directional coupler has been fabricated and tested for the validity of the design. Measured results are presented in this paper.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Both diglycine sulphate (DGS) and diglycine sulphate monohydrate (DGS.H2O) are reported to crystallize from solution with pH < 1(1,2). DGS.H2O (point group 2/m; Z = 4) shows a dielectric anomaly at 72°C suggestive of antiferroelectric transition(1). The crystals obtained by us from solution with pH < 0.5 at 20-25°C were always DGS (point group mmm; Z = 8) as confirmed by X-ray studies. The measurement of its dielectric constant along [100], [010] and [001] did not indicate any phase transition in the range 5-400°K. Thus DGS is a normal dielectric unlike TGS. The polarized Raman spectra and the infrared spectra were recorded to examine the configuration of glycine in DGS(3). The vibration spectra reveals that both the glycines in DGS exist as NH3+CH2COOH, thus precluding the hydrogen bond of the type N+-H…O- which exists between two glycine units in TGS. This seems to be a good reason for the difference in the dielectric behaviour of these two glycine sulphates.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a multi-class support vector machine (SVMs) approach for locating and diagnosing faults in electric power distribution feeders with the penetration of Distributed Generations (DGs). The proposed approach is based on the three phase voltage and current measurements which are available at all the sources i.e. substation and at the connection points of DG. To illustrate the proposed methodology, a practical distribution feeder emanating from 132/11kV-grid substation in India with loads and suitable number of DGs at different locations is considered. To show the effectiveness of the proposed methodology, practical situations in distribution systems (DS) such as all types of faults with a wide range of varying fault locations, source short circuit (SSC) levels and fault impedances are considered for studies. The proposed fault location scheme is capable of accurately identify the fault type, location of faulted feeder section and the fault impedance. The results demonstrate the feasibility of applying the proposed method in practical in smart grid distribution automation (DA) for fault diagnosis.