9 resultados para CLINICAL EVALUATION
em Indian Institute of Science - Bangalore - Índia
Resumo:
Technological forecasting, defined as quantified probabilistic prediction of timings and degree of change in the technological parameters, capabilities desirability or needs at different times in the future, is applied to birth control technology (BCT) as a means of revealing the paths of most promising research through identifying the necessary points for breakthroughs. The present status of BCT in the areas of pills and the IUD, male contraceptives, immumological approaches, post-coital pills, abortion, sterilization, luteolytic agents, laser technologies, and control of the sex of the child, are each summarized and evaluated in turn. Fine mapping is done to identify the most potentially promising areas of BCT. These include efforts to make oral contraception easier, improvement of the design of the IUD, clinical evaluation of the male contraceptive danazol, the effecting of biochemical changes in the seminal fluid, and researching of immunological approaches and the effects of other new drugs such as prostaglandins. The areas that require immediate and large research inputs are oral contraception and the IUD. On the basis of population and technological forecasts, it is deduced that research efforts could most effectively aid countries like India through the immediate production of an oral contraceptive pill or IUD with long-lasting effects. Development of a pill for males or an immunization against pre gnancy would also have a significant impact. However, the major impediment to birth control programs to date is attitudes, which must be changed through education.
Resumo:
Background & objectives: Pre-clinical toxicology evaluation of biotechnology products is a challenge to the toxicologist. The present investigation is an attempt to evaluate the safety profile of the first indigenously developed recombinant DNA anti-rabies vaccine DRV (100 mu g)] and combination rabies vaccine CRV (100 mu g DRV and 1.25 IU of cell culture-derived inactivated rabies virus vaccine)], which are intended for clinical use by intramuscular route in Rhesus monkeys. Methods: As per the regulatory requirements, the study was designed for acute (single dose - 14 days), sub-chronic (repeat dose - 28 days) and chronic (intended clinical dose - 120 days) toxicity tests using three dose levels, viz. therapeutic, average (2x therapeutic dose) and highest dose (10 x therapeutic dose) exposure in monkeys. The selection of the model i.e. monkey was based on affinity and rapid higher antibody response during the efficacy studies. An attempt was made to evaluate all parameters which included physical, physiological, clinical, haematological and histopathological profiles of all target organs, as well as Tiers I, II, III immunotoxicity parameters. Results: In acute toxicity there was no mortality in spite of exposing the monkeys to 10XDRV. In sub chronic and chronic toxicity studies there were no abnormalities in physical, physiological, neurological, clinical parameters, after administration of test compound in intended and 10 times of clinical dosage schedule of DRV and CRV under the experimental conditions. Clinical chemistry, haematology, organ weights and histopathology studies were essentially unremarkable except the presence of residual DNA in femtogram level at site of injection in animal which received 10X DRV in chronic toxicity study. No Observational Adverse Effects Level (NOAEL) of DRV is 1000 ug/dose (10 times of therapeutic dose) if administered on 0, 4, 7, 14, 28th day. Interpretation & conclusions: The information generated by this study not only draws attention to the need for national and international regulatory agencies in formulating guidelines for pre-clinical safety evaluation of biotech products but also facilitates the development of biopharmaceuticals as safe potential therapeutic agents.
Resumo:
Biomolecular structure elucidation is one of the major techniques for studying the basic processes of life. These processes get modulated, hindered or altered due to various causes like diseases, which is why biomolecular analysis and imaging play an important role in diagnosis, treatment prognosis and monitoring. Vibrational spectroscopy (IR and Raman), which is a molecular bond specific technique, can assist the researcher in chemical structure interpretation. Based on the combination with microscopy, vibrational microspectroscopy is currently emerging as an important tool for biomedical research, with a spatial resolution at the cellular and sub-cellular level. These techniques offer various advantages, enabling label-free, biomolecular fingerprinting in the native state. However, the complexity involved in deciphering the required information from a spectrum hampered their entry into the clinic. Today with the advent of automated algorithms, vibrational microspectroscopy excels in the field of spectropathology. However, researchers should be aware of how quantification based on absolute band intensities may be affected by instrumental parameters, sample thickness, water content, substrate backgrounds and other possible artefacts. In this review these practical issues and their effects on the quantification of biomolecules will be discussed in detail. In many cases ratiometric analysis can help to circumvent these problems and enable the quantitative study of biological samples, including ratiometric imaging in 1D, 2D and 3D. We provide an extensive overview from the recent scientific literature on IR and Raman band ratios used for studying biological systems and for disease diagnosis and treatment prognosis.
Resumo:
The pollen of Parthenium hysterophorus, an alien weed growing wild in India was found to be a potential source of allergic rhinitis. A clinical survey showed that 34% of the patients suffering from rhinitis and 12% suffering from bronchial asthma gave positive skin-prick test reactions to Parthenium pollen antigen extracts. Parthenium-specific IgE was detected in the sera of sixteen out of twenty-four patients suffering from seasonal rhinitis. There was 66% correlation between skin test and RAST.
Resumo:
Although the oxide ceramics have widely been investigated for their biocompatibility, non-oxide ceramics, such as SiAlON and SiC are yet to be explored in detail. Lack of understanding of the biocompatibility restricts the use of these ceramics in clinical trials. It is hence, essential to carry out proper and thorough study to assess cell adhesion, cytocompatibility and cell viability on the non-oxide ceramics for the potential applications. In this perspective, the present research work reports the cytocompatibility of gas pressure sintered SiAlON monolith and SiAlON-SiC composites with varying amount of SIC, using connective tissue cells (L929) and bone cells (Saos-2). The quantification of cell viability using MTT assay reveals the non-cytotoxic response. The cell viability has been found to be cell type dependent. An attempt has been made to discuss the cytocompatibility of the developed composites in the light of SiC content and type of sinter additives. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
Background: Deviated nasal septum (DNS) is one of the major causes of nasal obstruction. Polyvinylidene fluoride (PVDF) nasal sensor is the new technique developed to assess the nasal obstruction caused by DNS. This study evaluates the PVDF nasal sensor measurements in comparison with PEAK nasal inspiratory flow (PNIF) measurements and visual analog scale (VAS) of nasal obstruction. Methods: Because of piezoelectric property, two PVDF nasal sensors provide output voltage signals corresponding to the right and left nostril when they are subjected to nasal airflow. The peak-to-peak amplitude of the voltage signal corresponding to nasal airflow was analyzed to assess the nasal obstruction. PVDF nasal sensor and PNIF were performed on 30 healthy subjects and 30 DNS patients. Receiver operating characteristic was used to analyze the DNS of these two methods. Results: Measurements of PVDF nasal sensor strongly correlated with findings of PNIF (r = 0.67; p < 0.01) in DNS patients. A significant difference (p < 0.001) was observed between PVDF nasal sensor measurements and PNIF measurements of the DNS and the control group. A cutoff between normal and pathological of 0.51 Vp-p for PVDF nasal sensor and 120 L/min for PNIF was calculated. No significant difference in terms of sensitivity of PVDF nasal sensor and PNIF (89.7% versus 82.6%) and specificity (80.5% versus 78.8%) was calculated. Conclusion: The result shows that PVDF measurements closely agree with PNIF findings. Developed PVDF nasal sensor is an objective method that is simple, inexpensive, fast, and portable for determining DNS in clinical practice.
Resumo:
Lymphatic filariasis is the second leading cause of permanent long-term disability globally and control of this disease needs efficient diagnostic methods. In this study, abundantly expressing microfilarial sheath protein (Shp-1) from Brugia malayi was characterized as a filarial diagnostic candidate using samples from different clinical population. Monoclonal antibodies were developed against E. coil expressed recombinant Shp-1 in order to assess its efficiency in filarial antigen detection assay system. Endemic Normal (EN, n = 170), asymptomatic microfilaeremics (MF, n = 65), symptomatic chronic pathology (CP, n = 45) and non endemic normal (NEN, n = 10) sera were analyzed by antigen capture enzyme-linked immunosorbent assay. Of the 290 individuals, all MF individuals (both brugian and bancroftian) were positive in this assay followed by CP and EN. When compared with SXP-1 and Og4C3 antigen assays, all assays detected Wb MF correctly, Bm MF was detected by Shp-1 and SXP-1 assays, and only Shp-1 was able to detect EN (12%) and CP (29%). Results showed that this assay may be useful for monitoring prior to mass drug administration. (c) 2014 Elsevier Inc. All rights reserved.
Resumo:
Lymphatic filariasis is a parasitic disease of tropical countries. This is a disfiguring and painful disease contracted in childhood, but the symptoms become apparent only in later years. Diagnosis of filarial infection is very crucial for the management of the disease. The main objective of this study was to develop a filarial antigen-based immunological assay for the diagnosis and surveillance of the disease. Monoclonal and polyclonal antibodies were raised to the recombinant protein Brugia malayi vespid allergen homologue (VAH). Capture enzyme-linked immunosorbent assay (ELISA) was standardized utilizing various combinations of antibodies and evaluated with serum samples of endemic normal (EN, n = 110), microfilaraemic (MF, n = 65), chronic pathology (CP, n = 45) and non-endemic normal (NEN, n = 10) individuals. Of the 230 samples tested, VAHcapture assay detected circulating antigen in 97.91% of bancroftian and 100% of brugian microfilaraemic individuals, and 5% of endemic normal individuals, comparable to the earlier reported SXP-1 antigen detection assay. However, the combination of VAH and SXP-1 (VS) capture ELISA was found to be more robust, detecting 100% of microfilaraemic individuals and with higher binding values. Thus an antigen capture immunoassay has been developed, which can differentiate active infection from chronic infection by detecting circulating filarial antigens in clinical groups of endemic areas.
Resumo:
The screen printed electrochemical glucose sensor is developed suitable for revere iontophoresis (RI) application. Glucose oxidase is immobilized on screen printed sensor using crosslinking method. Electrochemical and material characterization studies are conducted on the developed sensor and the obtained results confirm the suitability of the developed sensor for RI application. The developed sensor is validated by conducting clinical investigations on 10 human subjects through RI. A correlation is established between the blood glucose and extracted glucose, and correlation is found to be 0.73. (C) 2015 The Electrochemical Society. All rights reserved.