24 resultados para Blunt, John, Sir, 1665-1733.
em Indian Institute of Science - Bangalore - Índia
Resumo:
In uplink orthogonal frequency division multiple access (OFDMA), large timing offsets (TO) and/or carrier frequency offsets (CFO) of other users with respect to a desired user can cause significant multiuser interference (MUI). In this letter, we analytically characterize the degradation in the average output signal-to-interference ratio (SIR) due to the combined effect of both TOs as well as CFOs in uplink OFDMA. Specifically, we derive closed-form expressions for the average SIR at the DFT output in the presence of large CFOs and TOs. The analyticalexpressions derived for the signal and various interference terms at the DFT output are used to devise an interference cancelling receiver to mitigate the effect of CFO/TO-induced interferences.
Resumo:
Drag reduction studies are conducted using a flat disc tipped aerospike for a 120-degree apex angle blunt cone model in high enthalpy flows. Accelerometer based force balance is used for the drag force measurement in the newly established free piston driven shock tunnel, HST3. Drag reduction upto about 58 percent has been achieved for Mach 8 flow of 5 MJ/kg specific enthalpy at zero degree angle of attack.
Resumo:
Counterflow supersonic jet is used as a drag reduction device during the experiments in free piston driven shock tunnel, HST3. Accelerometer based force balance is employed to measure the drag force experienced by the 60-degree apex angle blunt cone model without and with the supersonic jet opposing the hypersonic flow. It is observed that the drag force decreases with increase in injection pressure ratio until the critical injection pressure is reached. Maximum reduction in drag force of 44 percent is recorded at the critical injection pressure ratio 22.36. Further increase in injection pressure ratio has reduced the percentage drag reduction. Change in nature of the flowfield around the model has also been observed across the critical injection pressure ratio.
Resumo:
Experimental results on the effect of energy deposition using an electric arc discharge, upstream of a 60° half angle blunt cone configuration in a hypersonic flow is reported.Investigations involving drag measurements and high speed schlieren flow visualization have been carried out in hypersonic shock tunnel using air and argon as the test gases; and an unsteady drag reduction of about 50% (maximum reduction) has been observed in the energy deposition experiments done in argon environment. These studies also show that the effect of discharge on the flow field is more pronounced in argon environment as compared to air, which confirms that thermal effects are mainly responsible for flow alteration in presence of the discharge.
Resumo:
The flow around a 120 degrees blunt cone model with a base radius of 60mm has been visualised at Mach 14.8 and 9.1 using argon as the test gas, at the newly established high speed schlieren facility in the IISc hypersonic shock tunnel HST2. The experimental shock stand off distance around the blunt cone is compared with that obtained using a commercial CFD package. The computed values of shock stand off distance of the blunt cone is found to agree reasonably well with the experimental data.
Resumo:
In uplink OFDMA, carrier frequency offsets (CFO) and/or timing offsets (TO) of other users with respect to a desired user can cause multiuser interference (MUI). In practical uplink OFDMA systems (e.g., IEEE 802.16e standard), effect of this MUI is made acceptably small by requiring that frequency/timing alignment be achieved at the receiver with high precision (e.g., CFO must be within 1 % of the subcarrier spacing and TO must be within 1/8th of the cyclic prefix duration in IEEE 802.16e), which is realized using complex closed-loop frequency/timing correction between the transmitter and the receiver. An alternate open-loop approach to handle the MUI induced by large CFOs and TOs is to employ interference cancellation techniques at the receiver. In this paper, we first analytically characterize the degradation in the average output signal-to-interference ratio (SIR) due to the combined effect of large CFOs and TOs in uplink OFDMA. We then propose a parallel interference canceller (PIC) for the mitigation of interference due to CFOs and TOs in this system. We show that the proposed PIC effectively mitigates the performance loss due to CFO/TO induced interference in uplink OFDMA.
Resumo:
In this paper, the steady laminar viscous hypersonic flow of an electrically conducting fluid in the region of the stagnation point of an insulating blunt body in the presence of a radial magnetic field is studied by similarity solution approach, taking into account the variation of the product of density and viscosity across the boundary layer. The two coupled non-linear ordinary differential equations are solved simultaneously using Runge-Kutta-Gill method. It has been found that the effect of the variation of the product of density and viscosity on skin friction coefficient and Nusselt number is appreciable. The skin friction coefficient increases but Nusselt number decreases as the magnetic field or the total enthalpy at the wall increases
Resumo:
Aerodynamic forces and fore-body convective surface heat transfer rates over a 60 degrees apex-angle blunt cone have been simultaneously measured at a nominal Mach number of 5.75 in the hypersonic shock tunnel HST2. An aluminum model incorporating a three-component accelerometer-based balance system for measuring the aerodynamic forces and an array of platinum thin-film gauges deposited on thermally insulating backing material flush mounted on the model surface is used for convective surface heat transfer measurement in the investigations. The measured value of the drag coefficient varies by about +/-6% from the theoretically estimated value based on the modified Newtonian theory, while the axi-symmetric Navier-Stokes computations overpredict the drag coefficient by about 9%. The normalized values of measured heat transfer rates at 0 degrees angle of attack are about 11% higher than the theoretically estimated values. The aerodynamic and the heat transfer data presented here are very valuable for the validation of CFD codes used for the numerical computation of How fields around hypersonic vehicles.
Resumo:
A secreted lectin, Rv1419, from Mycobacterium tuberculosis has been cloned, expressed, purified and crystallized and the crystals have been characterized. This represents the first X-ray investigation of a lectin or lectin-like molecule from the pathogen. The cubic crystals contain one molecule in the asymmetric unit. Sequence comparisons indicate that the lectin has a beta-trefoil fold and belongs to a well characterized family of carbohydrate-binding modules. Structural analysis of the crystals is in progress.
Resumo:
A study of transpiration cooling of blunt bodies such as a hemicylinder is made by solving Navier-Stokes equations. An upwind, implicit time-marching code is developed for this purpose. The study is conducted for both perfect-gas and real-gas (chemical equilibrium) flows. Investigations are carried out for a special wall condition that is referred to as no heat flow into the wall condition. The effects of air injection on wall temperature are analyzed. Analyses are carried out for Mach numbers ranging between 6-10 and Reynolds numbers ranging between 10(6)-10(7). Studies are made for spatially constant as well as spatially varying mass injection rate distributions, White cold air injection reduces the wall temperature substantially, transpiration cooling is relatively less effective when the gas is in chemical equilibrium.
Resumo:
The effect of the test gas on the flow field around a 120degrees apex angle blunt cone has been investigated in a shock tunnel at a nominal Mach number of 5.75. The shock standoff distance around the blunt cone was measured by an electrical discharge technique using both carbon dioxide and air as test gases. The forebody laminar convective heat transfer to the blunt cone was measured with platinum thin-film sensors in both air and carbon dioxide environments. An increase of 10 to 15% in the measured heat transfer values was observed with carbon dioxide as the test gas in comparison to air. The measured thickness of the shock layer along the stagnation streamline was 3.57 +/- 0.17 mm in air and 3.29 +/- 0.26 mm in carbon dioxide. The computed thickness of the shock layer for air and carbon dioxide were 3.98 mm and 3.02 mm, respectively. The observed increase in the measured heat transfer rates in carbon dioxide compared to air was due to the higher density ratio across the bow shock wave and the reduced shock layer thickness.