16 resultados para Animal monitor

em Indian Institute of Science - Bangalore - Índia


Relevância:

30.00% 30.00%

Publicador:

Resumo:

We evaluated trained listener-based acoustic sampling as a reliable and non-invasive method for rapid assessment of ensiferan species diversity in tropical evergreen forests. This was done by evaluating the reliability of identification of species and numbers of calling individuals using psychoacoustic experiments in the laboratory and by comparing psychoacoustic sampling in the field with ambient noise recordings made at the same time. The reliability of correct species identification by the trained listener was 100% for 16 out of 20 species tested in the laboratory. The reliability of identifying the numbers of individuals correctly was 100% for 13 out of 20 species. The human listener performed slightly better than the instrument in detecting low frequency and broadband calls in the field, whereas the recorder detected high frequency calls with greater probability. To address the problem of pseudoreplication during spot sampling in the field, we monitored the movement of calling individuals using focal animal sampling. The average distance moved by calling individuals for 17 out of 20 species was less than 1.5 m in half an hour. We suggest that trained listener-based sampling is preferable for crickets and low frequency katydids, whereas broadband recorders are preferable for katydid species with high frequency calls for accurate estimation of ensiferan species richness and relative abundance in an area.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Monitoring gas purity is an important aspect of gas recovery stations where air is usually one of the major impurities. Purity monitors of Katherometric type ate commercially available for this purpose. Alternatively, we discuss here a helium gas purity monitor based on acoustic resonance of a cavity at audio frequencies. It measures the purity by monitoring the resonant frequency of a cylindrical cavity filled with the gas under test and excited by conventional telephone transducers fixed at the ends. The use of the latter simplifies the design considerably. The paper discusses the details of the resonant cavity and the electronic circuit along with temperature compensation. The unit has been calibrated with helium gas of known purities. The unit has a response time of the order of 10 minutes and measures the gas purity to an accuracy of 0.02%. The unit has been installed in our helium recovery system and is found to perform satisfactorily.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A highly stable oscillator used in a quartz crystal thickness monitor for monitoring the rate of evaporation and total thickness of film during thin film deposition is reported. The design aspects of the oscillator and its long term stability, which enhances the reproducibility and the performance of the thickness monitor, are discussed. The stability of the oscillator at defined conditions is tested and compared with the conventional transistorized oscillator and the IC oscillator using inverters. The oscillator is coupled to the crystal monitor and its performance is studied in an evaporation system by evaporating different materials

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A plethora of indices have been proposed and used to construct dominance hierarchies in a variety of vertebrate and invertebrate societies, although the rationale for choosing a particular index for a particular species is seldom explained. In this study, we analysed and compared three such indices, viz Clutton-Brock et al.'s index (CBI), originally developed for red deer, Cervus elaphus, David's score (DS) originally proposed by the statistician H. A. David and the frequency-based index of dominance (FDI) developed and routinely used by our group for the primitively eusocial wasps Ropalidia marginata and Ropalidia cyathiformis. Dominance ranks attributed by all three indices were strongly and positively correlated for both natural data sets from the wasp colonies and for artificial data sets generated for the purpose. However, the indices differed in their ability to yield unique (untied) ranks in the natural data sets. This appears to be caused by the presence of noninteracting individuals and reversals in the direction of dominance in some of the pairs in the natural data sets. This was confirmed by creating additional artificial data sets with noninteracting individuals and with reversals. Based on the criterion of yielding the largest proportion of unique ranks, we found that FDI is best suited for societies such as the wasps belonging to Ropalidia, DS is best suited for societies with reversals and CBI remains a suitable index for societies such as red deer in which multiple interactions are uncommon. (C) 2009 The Association for the Study of Animal Behaviour. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A generalized power tracking algorithm that minimizes power consumption of digital circuits by dynamic control of supply voltage and the body bias is proposed. A direct power monitoring scheme is proposed that does not need any replica and hence can sense total power consumed by load circuit across process, voltage, and temperature corners. Design details and performance of power monitor and tracking algorithm are examined by a simulation framework developed using UMC 90-nm CMOS triple well process. The proposed algorithm with direct power monitor achieves a power savings of 42.2% for activity of 0.02 and 22.4% for activity of 0.04. Experimental results from test chip fabricated in AMS 350 nm process shows power savings of 46.3% and 65% for load circuit operating in super threshold and near sub-threshold region, respectively. Measured resolution of power monitor is around 0.25 mV and it has a power overhead of 2.2% of die power. Issues with loop convergence and design tradeoff for power monitor are also discussed in this paper.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Long-distance dispersal (LDD) events, although rare for most plant species, can strongly influence population and community dynamics. Animals function as a key biotic vector of seeds and thus, a mechanistic and quantitative understanding of how individual animal behaviors scale to dispersal patterns at different spatial scales is a question of critical importance from both basic and applied perspectives. Using a diffusion-theory based analytical approach for a wide range of animal movement and seed transportation patterns, we show that the scale (a measure of local dispersal) of the seed dispersal kernel increases with the organisms' rate of movement and mean seed retention time. We reveal that variations in seed retention time is a key determinant of various measures of LDD such as kurtosis (or shape) of the kernel, thinkness of tails and the absolute number of seeds falling beyond a threshold distance. Using empirical data sets of frugivores, we illustrate the importance of variability in retention times for predicting the key disperser species that influence LDD. Our study makes testable predictions linking animal movement behaviors and gut retention times to dispersal patterns and, more generally, highlights the potential importance of animal behavioral variability for the LDD of seeds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reproductive management of the Asian elephant (Elephas maximus) is important for its conservation. To monitor its estrous cyclicity, we earlier used an indirect ELISA to show that levels of fecal progesterone (P(4))-metabolite (allopregnanolone: 5 alpha-P-3OH) in semi-captive females sampled randomly positively correlated with serum P(4) levels [12]. In this longitudinal study (51 weeks), we measured levels of fecal 5 alpha-P-3OH and serum P(4) in seven semi-captive female elephants. Females exhibited three types of hormonal profiles. Four females showed cyclical patterns of fecal 5 alpha-P-3OH and serum P(4) typical of normal estrous cycles, two showed acyclic pattern while one showed high values indicative of a pregnant animal. Values for anestrous or follicular phases were <= 0.3 mu g g(-1), (5 alpha-P-3OH) and <= 0.3 ng mL(-1) (P(4)); for luteal phase 0.32-11.09 mu g g(-1) (5 alpha-P-3OH) and 0.32-1.48 ng mL(-1) (P(4)); for pregnancy 1.41-7.38 mu g g(-1) (5 alpha-P-3OH) and 0.39-1.6 ng mL(-1) (R(4)). A positive correlation (t = 8.8, p < 0.01, n = 321) between levels of fecal 5 alpha-P-3OH and serum P4 was observed. A random sample of 30 free-ranging female elephants showed fecal 5 alpha-P-3OH values of 0.06-23.4 mu g g(-1), indicating them to be in different stages of estrous cyclicity. This study is the first to assess the reproductive phases of female Asian elephants based on the correlative-patterns of both the fecal 5 alpha-P-3OH and serum P(4) values over multiple estrous cycles. This has a potential application in the reproductive management and conservation of Asian elephants. (C) 2011 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A generalized power tracking algorithm that minimizes power consumption of digital circuits by dynamic control of supply voltage and the body bias is proposed. A direct power monitoring scheme is proposed that does not need any replica and hence can sense total power consumed by load circuit across process, voltage, and temperature corners. Design details and performance of power monitor and tracking algorithm are examined by a simulation framework developed using UMC 90-nm CMOS triple well process. The proposed algorithm with direct power monitor achieves a power savings of 42.2% for activity of 0.02 and 22.4% for activity of 0.04. Experimental results from test chip fabricated in AMS 350 nm process shows power savings of 46.3% and 65% for load circuit operating in super threshold and near sub-threshold region, respectively. Measured resolution of power monitor is around 0.25 mV and it has a power overhead of 2.2% of die power. Issues with loop convergence and design tradeoff for power monitor are also discussed in this paper.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Design and development of a piezoelectric polyvinylidene fluoride (PVDF) thin film based nasal sensor to monitor human respiration pattern (RP) from each nostril simultaneously is presented in this paper. Thin film based PVDF nasal sensor is designed in a cantilever beam configuration. Two cantilevers are mounted on a spectacle frame in such a way that the air flow from each nostril impinges on this sensor causing bending of the cantilever beams. Voltage signal produced due to air flow induced dynamic piezoelectric effect produce a respective RP. A group of 23 healthy awake human subjects are studied. The RP in terms of respiratory rate (RR) and Respiratory air-flow changes/alterations obtained from the developed PVDF nasal sensor are compared with RP obtained from respiratory inductance plethysmograph (RIP) device. The mean RR of the developed nasal sensor (19.65 +/- A 4.1) and the RIP (19.57 +/- A 4.1) are found to be almost same (difference not significant, p > 0.05) with the correlation coefficient 0.96, p < 0.0001. It was observed that any change/alterations in the pattern of RIP is followed by same amount of change/alterations in the pattern of PVDF nasal sensor with k = 0.815 indicating strong agreement between the PVDF nasal sensor and RIP respiratory air-flow pattern. The developed sensor is simple in design, non-invasive, patient friendly and hence shows promising routine clinical usage. The preliminary result shows that this new method can have various applications in respiratory monitoring and diagnosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In view of the fact that bone healing can be enhanced due to external electric field application, it is important to assess the influence of the implant conductivity on the bone regeneration in vivo. To address this issue, this study reports the in vivo biocompatibility property of multistage spark plasma sintered hydroxyapatite (HA)-80 wt % calcium titanate (CaTiO3) composites and monolithic HA, which have widely different conductivity property (14 orders of magnitude difference). The ability of bone regeneration was assessed by implantation in cylindrical femoral bone defects of rabbit animal model for varying time period of 1, 4, and 12 weeks. The overall assessment of the histology results suggests that the progressive healing of bone defects around HA-80 wt % CaTiO3 is associated with a better efficacy with respect to (w.r.t) early stage neobone formation, which is histomorphometrically around 140% higher than monolithic HA. Overall, this study demonstrates that the in vivo biocompatibility property of HA-80 wt % CaTiO3 with respect to local effects after 12 weeks of implantation is not compromised both qualitatively and quantitatively, and a comparison with control implant (HA) points toward the critical role of electrical conductivity on better early stage bone regeneration. (c) 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 102A: 842-851, 2014.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work reports the biocompatibility property of injection molded HDPE-HA-Al2O3 hybrid composites. In vitro cytocompatibility results reveal that osteogenic cell viability and bone mineralization are favorably supported in a statistically significant manner on HDPE-20% HA-20% Al2O3 composite, in comparison to HDPE-40 wt.% HA or HDPE-40 wt.% Al2O3. The difference in cytocompatibility property is explained in terms of difference in substrate wettability/surface energy and importantly, both the cell proliferation at 7 days or bone mineralization at 21 days on HDPE-20% HA-20% Al2O3 composite are either comparable or better than sintered HA. The progressive healing of cylindrical femoral bone defects in rabbit animal model was assessed by implantation experiments over 1, 4 and 12 weeks. Based on the histological analysis as well as histomorphometrical evaluation, a better efficacy of HDPE-20% HA-20% Al2O3 over high-density polyethylene (HDPE) for bone regeneration and neobone formation at host bone-implant interface was established. Taken together, the present study unequivocally establishes that despite the presence of 20% Al2O3, HDPE-based hybrid composites are as biocompatible as HA in vitro or better than HDPE in vivo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present article describes a beautiful contribution of Alan Turing to our understanding of how animal coat patterns form. The question that Turing posed was the following. A collection of identical cells (or processors for that matter), all running the exact same program, and all communicating with each other in the exact same way, should always be in the same state. Yet they produce nonhomogeneous periodic patterns, like those seen on animal coats. How does this happen? Turing gave an elegant explanation for this phenomenon, namely that differences between the cells due to small amounts of random noise can actually be amplified into structured periodic patterns. We attempt to describe his core conceptual contribution below.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigated the potential of using novel zoledronic acid (ZOL)-hydroxyapatite (HA) nanoparticle based drug formulation in a rat model of postmenopausal osteoporosis. By a classical adsorption method, nanoparticles of HA loaded with ZOL (HNLZ) drug formulation with a size range of 100-130 nm were prepared. 56 female Wistar rats were ovariectomized (OVX) or sham-operated at 3 months of age. Twelve weeks post surgery, rats were randomized into seven groups and treated with various doses of HNLZ (100, 50 and 25 mu g/kg, intravenous single dose), ZOL (100 mu g/kg, intravenous single dose) and HA nanoparticle (100 mu g/kg, intravenous single dose). Untreated OVX and sham OVX served as controls. After three months treatment period, we evaluated the mechanical properties of the lumbar vertebra and femoral mid-shaft. Femurs were also tested for trabecular microarchitecture. Sensitive biochemical markers of bone formation and bone resorption in serum were also determined. With respect to improvement in the mechanical strength of the lumbar spine and the femoral mid-shaft, the therapy with HNLZ drug formulation was more effective than ZOL therapy in OVX rats. Moreover, HNLZ drug therapy preserved the trabecular microarchitecture better than ZOL therapy in OVX rats. Furthermore, the HNLZ drug formulation corrected increase in serum levels of bone-specific alkaline phosphatase, procollagen type I N-terminal propeptide, osteocalcin, tartrate-resistant acid phosphatase 5b and C-telopeptide of type 1 collagen better than ZOL therapy in OVX rats. The results strongly suggest that HNLZ novel drug formulation appears to be more effective approach for treating severe osteoporosis in humans. (C) 2014 Elsevier B.V. All rights reserved.