186 resultados para short circuit currents
Resumo:
Transfer function coefficients (TFC) are widely used to test linear analog circuits for parametric and catastrophic faults. This paper presents closed form expressions for an upper bound on the defect level (DL) and a lower bound on fault coverage (FC) achievable in TFC based test method. The computed bounds have been tested and validated on several benchmark circuits. Further, application of these bounds to scalable RC ladder networks reveal a number of interesting characteristics. The approach adopted here is general and can be extended to find bounds of DL and FC of other parametric test methods for linear and non-linear circuits.
Resumo:
A novel methodology for modeling the effects of process variations on circuit delay performance is proposed by relating the variations in process parameters to variations in delay metric of a complex digital circuit. The delay of a 2-input NAND gate with 65nm gate length transistors is extensively characterized by mixed-mode simulations which is then used as a library element. The variation in saturation current Ionat the device level, and the variation in rising/falling edge stage delay for the NAND gate at the circuit level, are taken as performance metrics. A 4-bit x 4-bit Wallace tree multiplier circuit is used as a representative combinational circuit to demonstrate the proposed methodology. The variation in the multiplier delay is characterized, to obtain delay distributions, by an extensive Monte Carlo analysis. An analytical model based on CV/I metric is proposed, to extend this methodology for a generic technology library with a variety of library elements.
Resumo:
An extension to a formal verification approach of hybrid systems is proposed to verify analog and mixed signal (AMS) designs. AMS designs can be formally modeled as hybrid systems and therefore lend themselves to the formal analysis and verification techniques applied to hybrid systems. The proposed approach employs simulation traces obtained from an actual design implementation of AMS circuit blocks (for example, in the form of SPICE netlists) to carry out formal analysis and verification. This enables the same platform used for formally validating an abstract model of an AMS design, to be also used for validating its different refinements and design implementation; thereby, providing a simple route to formal verification at different levels of implementation. The feasibility of the proposed approach is demonstrated with a case study based on a tunnel diode oscillator. Since the device characteristic of a tunnel diode is highly non-linear with a negative resistance region, dynamic behavior of circuits in which it is employed as an element is difficult to model, analyze and verify within a general hybrid system formal verification tool. In the case study presented the formal model and the proposed computational techniques have been incorporated into CheckMate, a formal verification tool based on MATLAB and Simulink-Stateflow Framework from MathWorks.
Resumo:
The firing characteristics of the simple triggered vacuum gap (TVG) using lead zirconate titanate as dielectric material in the triggered gap are described. This TVG has a long life of about 2000 firings without appreciable deterioration of the electrical properties for main discharge currents upto 3 kA and is much superior to these made with Supramica (Mycalex Corporation of America) and silicon carbide as used in our earlier investigations. The effects of the variation of trigger voltage, trigger curcit, trigger pulse duration, trigger pulse energy, main gap voltage, main gap separation and main circuit energy on the firing characteristics have been studied. Trigger resistance progressively decreases with the number of firings of the trigger gap and as well as of the main gap. This decrease in the trigger resistance is more pronounced for main discharge currents exceeding 10 kA. The minimum trigger current required for reliable firing decreases with increase of trigger voltage upto a threshold value of 1.2 kV and there-onwards saturates at 3.0 A. This value is less than that obtained with Supramica as dielectric material. One hundred percent firing probability of the TVG at main gap voltages as low as 50 V is possible and this low voltage breakdown of the main gap appears to be similar to the breakdown at low pressures between moving plasma by other workers. and the cold electrodes immersed in it, as reported.
Resumo:
A mathematical model has been proposed to determine the voltage/current characteristic of the surge diverter for a wide range of currents of short duration of 8/20 and 4/10ÿs waveshapes. Experimental data agree well with the proposed model.
Resumo:
Abstract | Non-crystalline or glassy semiconductors are of great research interest for the fabrication of large area electronic systems such as displays and image sensors. Good uniformity over large areas, low temperature fabrication and the promise of low cost electronics on large area mechanically flexible and rigid substrates are some attractive features of these technologies. The article focusses on amorphous hydrogenated silicon thin film transistors, and reviews the problems, solutions and applications of these devices.
Resumo:
A new six-component accelerometer force balance is developed and used in the HST2 shock tunnel of Indian Institute of Science. Aerodynamic forces and moments for a hypersonic slender body measured using this balance system at a free stream Mach number of 5.75 and Reynolds number of 1.5 million and stagnation enthalpy of 1.5 and 2 MJ/kg are presented. These measured values compare well with the theoretical values estimated using modified Newtonian theory.
Resumo:
Creep properties of QE22 magnesium based alloy and composites reinforced with 20 volume percent of short-fibers - Maftech (R), Saffil (R) or Supertech (R), were evaluated using the impression creep test. In the impression creep test, a load is applied with the help of a cylindrical tungsten carbide indenter of 1 mm diameter. This has advantages over conventional creep testing in terms of small specimen size requirement and simple machining. Depth of impression is recorded with time and steady state strain rate is obtained from the slope of the secondary strain (depth of impression divided by indenter diameter) vs. time plot. The results are compared with the creep obtained from conventional creep performed in tension on the same materials earlier. Microstructural examination of the plastically deformed regions is carried out to explain creep behaviour of these composites.
Resumo:
This paper proposes a method of short term load forecasting with limited data, applicable even at 11 kV substation levels where total power demand is relatively low and somewhat random and weather data are usually not available as in most developing countries. Kalman filtering technique has been modified and used to forecast daily and hourly load. Planning generation and interstate energy exchange schedule at load dispatch centre and decentralized Demand Side Management at substation level are intended to be carried out with the help of this short term load forecasting technique especially to achieve peak power control without enforcing load-shedding.