256 resultados para onshore gas platform


Relevância:

20.00% 20.00%

Publicador:

Resumo:

It has been well recognized now that the blast furnace aerodynamics can be represented more accurately under the decreasing gas velocity condition. Therefore, gas-fines study has been carried out in a packed bed under the decreasing gas velocity condition. Gas and fines flow equations have been developed and solved, for two-dimensional case using finite volume method. To take into account the turbulence, k-e turbulent flow model has also been developed in two-dimension. The model's predictions have been validated against the published experimental data for the increasing gas velocity case, as no experimental data are available in open literature for the decreasing gas velocity. This study shows the difference in the results for increasing and decreasing gas velocity cases under various conditions which have been reported here. Implication of the results to the blast furnace condition has also been discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The discharge plasma-chemical hybrid process for NOinfinity removal from the flue gas emissions is an extremely effective and economical approach in comparison with the conventional selective catalytic reduction system. In this paper we bring out a relative comparison of several discharge plasma reactors from the point of NO removal efficiency. The reactors were either energized by ac or by repetitive pulses. Ferroelectric pellets were used to study the effect of pellet assisted discharges on gas cleaning. Diesel engine exhaust, at different loads; is used to approximately simulate the flue gas composition. Investigations were carried out at room temperature with respect to the variation of reaction products against the discharge power. Main emphasis is laid on the oxidation of NO to NO2, without reducing NOx concentration (i.e., minimum reaction byproducts), with least power consumption. The produced NO2 will be totally converted to N-2 and Na-2 SO4 using Na-2 SO3. The ac packed-bed reactor and pelletless pulsed corona reactor showed better performance, with minimum reaction products for a given power, when the NO concentration was low (similar to 100 ppm). When the engine load exceeds 50% (NO > 300 ppm) there was not much decrease in NO reduction and more or less all the reactors performed equally. The total operating cost of the plasma-chemical hybrid system becomes $4010/ton of NO, which is 1/3-1/5 of the conventional selective catalytic process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One of the assumptions of the van der Waals and Platteeuw theory for gas hydrates is that the host water lattice is rigid and not distorted by the presence of guest molecules. In this work, we study the effect of this approximation on the triple-point lines of the gas hydrates. We calculate the triple-point lines of methane and ethane hydrates via Monte Carlo molecular simulations and compare the simulation results with the predictions of van der Waals and Platteeuw theory. Our study shows that even if the exact intermolecular potential between the guest molecules and water is known, the dissociation temperatures predicted by the theory are significantly higher. This has serious implications to the modeling of gas hydrate thermodynamics, and in spite of the several impressive efforts made toward obtaining an accurate description of intermolecular interactions in gas hydrates, the theory will suffer from the problem of robustness if the issue of movement of water molecules is not adequately addressed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Spray formation in ambient atmosphere from gas-centered swirl coaxial atomizers is described by carrying out experiments in a spray test facility. The atomizer discharges a circular air jet and an axisymmetric swirling water sheet from its coaxially arranged inner and outer orifices. A high-speed digital imaging system along with a backlight illumination arrangement is employed to record the details of liquid sheet breakup and spray development. Spray regimes exhibiting different sheet breakup mechanisms are identified and their characteristic features presented. The identified spray regimes are wave-assisted sheet breakup, perforated sheet breakup, segmented sheet breakup, and pulsation spray regime. In the regime of wave-assisted sheet breakup, the sheet breakup shows features similar to the breakup of two-dimensional planar air-blasted liquid sheets. At high air-to-liquid momentum ratios, the interaction process between the axisymmetric swirling liquid sheet and the circular air jet develops spray processes which are more specific to the atomizer studied here. The spray exhibits a periodic ejection of liquid masses whose features are dominantly controlled by the central air jet.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article reports the greenhouse gas emissions of anthropogenic origin by sources and removals by sinks of India for 2007 prepared under the aegis of the Indian Network for Climate Change Assessment (INCCA) (note 1). The emission profile includes carbon dioxide (CO(2)), methane and nitrous oxide. It also includes the estimates of hydrofluorocarbons, perfluorocarbons and sulphur hexafluoride at the national level from various sectors, viz, energy, industrial process and product use, agriculture, land-use, land-use change and forestry (LULUCF), and waste. In 2007, emissions were of the order of 2008.67 Tg (note 2) of CO(2) equivalents without emissions from the LULUCF sector. Whereas with LULUCF the emissions were about 1831.65 Tg CO(2) equivalents. The energy sector accounted for 69% of the total emissions, the agriculture sector contributed 19% of the emissions, 9% of the emissions was from the industrial processes and product use, and only 3% of the emissions was attributable to the waste sector. The LULUCF sector on the whole was net sink category for CO(2). The study tracks the improvements made in inventory estimates at the national level through the years, in terms of the expanding coverage of sources, reducing uncertainties and inclusion of new methodologies, including some elements of future areas of work.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Based on the an earlier CFD analysis of the performance of the gas-dynamically controlled laser cavity [1]it was found that there is possibility of optimizing the geometry of the diffuser that can bring about reductions in both size and cost of the system by examining the critical dimensional requirements of the diffuser. Consequently,an extensive CFD analysis has been carried out for a range of diffuser configurations by simulating the supersonic flow through the arrangement including the laser cavity driven by a bank of converging – diverging nozzles and the diffuser. The numerical investigations with 3D-RANS code are carried out to capture the flow patterns through diffusers past the cavity that has multiple supersonic jet interactions with shocks leading to complex flow pattern. Varying length of the diffuser plates is made to be the basic parameter of the study. The analysis reveals that the pressure recovery pattern during the flow through the diffuser from the simulation, being critical for the performance of the laser device shows its dependence on the diffuser length is weaker beyond a critical lower limit and this evaluation of this limit would provide a design guideline for a more efficient system configuration.The observation based on the parametric study shows that the pressure recovery transients in the near vicinity of the cavity is not affected for the reduction in the length of the diffuser plates up to its 10% of the initial size, indicating the design in the first configuration that was tested experimentally has a large factor of margin. The flow stability in the laser cavity is found to be unaffected since a strong and stable shock is located at the leading edge of the diffuser plates while the downstream shock and flow patterns are changed, as one would expect. Results of the study for the different lengths of diffusers in the range of 10% to its full length are presented, keeping the experimentally tested configuration used in the earlier study [1] as the reference length. The conclusions drawn from the analysis is found to be of significance since it provides new design considerations based on the understanding of the intricacies of the flow, allowing for a hardware optimization that can lead to substantial size reduction of the device with no loss of performance.