219 resultados para few-cycle pulse


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Packaging Research Center has been developing next generation system-on-a-package (SOP) technology with digital, RF, optical, and sensor functions integrated in a single package/module. The goal of this effort is to develop a platform substrate technology providing very high wiring density and embedded thin film passive and active components using PWB compatible materials and processes. The latest SOP baseline process test vehicle has been fabricated on novel Si-matched CTE, high modulus C-SiC composite core substrates using 10mum thick BCB dielectric films with loss tangent of 0.0008 and dielectric constant of 2.65. A semi-additive plating process has been developed for multilayer microvia build-up using BCB without the use of any vacuum deposition or polishing/CMP processes. PWB and package substrate compatible processes such as plasma surface treatment/desmear and electroless/electrolytic pulse reverse plating was used. The smallest line width and space demonstrated in this paper is 6mum with microvia diameters in the 15-30mum range. This build-up process has also been developed on medium CTE organic laminates including MCL-E-679F from Hitachi Chemical and PTFE laminates with Cu-Invar-Cu core. Embedded decoupling capacitors with capacitance density of >500nF/cm2 have been integrated into the build-up layers using sol-gel synthesized BaTiO3 thin films (200-300nm film thickness) deposited on copper foils and integrated using vacuum lamination and subtractive etch processes. Thin metal alloy resistor films have been integrated into the SOP substrate using two methods: (a) NiCrAlSi thin films (25ohms per square) deposited on copper foils (Gould Electronics) laminated on the build-up layers and two step etch process for resistor definition, and (b) electroless plated Ni-W-P thin films (70 ohms to few Kohms per square) on the BCB dielectric by plasma surface treatment and activation. The electrical design and build-up layer structure along- - with key materials and processes used in the fabrication of the SOP4 test vehicle were presented in this paper. Initial results from the high density wiring and embedded thin film components were also presented. The focus of this paper is on integration of materials, processes and structures in a single package substrate for system-on-a-package (SOP) implementation

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Substantial increase in competition compels design firms to develop new products at an increasingly rapid pace. This situation pressurizes engineering teams to develop better products and at the same time develop products faster [1]. Continuous innovation is a key factor to enable a company to generate profit on a continued basis, through the introduction of new products in the market – a prime intention for Product Lifecycle Management. Creativity, affecting a wide spectrum of business portfolios, is regarded as the crucial factor for designing products. A central goal of product development is to create products that are sufficiently novel and useful. This research focuses on the determination of novelty of engineering products. Determination of novelty is important for ascertaining the newness of a product, to decide on the patentability of the design, to compare designers' capability of solving problems and to ascertain the potential market of a product. Few attempts at measuring novelty is available in literature [2, 3, 4], but more in-depth research is required for assessing degree of novelty of products. This research aims to determine the novelty of a product by enabling a person to determine the degree of novelty in a product. A measure of novelty has been developed by which the degree of ''novelty'' of products can be ascertained. An empirical study has been conducted to determine the validity of this method for determining the 'novelty' of the products.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pulse retardation method of Breit and Tuve has been modified to record continuously the equivalent height as well as the intensity of reflections from the ionosphere. Synchronized pulses are transmitted, and the received ground pulse and the reflected pulses, after amplification and suitable distortion, are applied to the focusing cylinder of a cathode ray tube the horizontal deflecting plates of which are connected to a synchronized linear time base circuit. The pattern on the screen is composed of a bright straight line corresponding to the time base with dark gaps corresponding to the received pulses. The distance between the initial points of the gaps represents retardation while the widths of the gaps correspond to the intensity of the pulses. The pattern is photographed on a vertically moving film. One of the first few records taken at Bangalore on 4 megacycles is reproduced. It shows, among other things, that the less retarded component of magneto-ionic splitting from the F layer is present most of the time. Whenever the longer retardation component does occur, it has stronger intensity than the former. Towards the late evening hours, just before disappearing, when the F layer rises and exhibits magnetoionic splitting, the intensity of the less retarded component is extremely low compared with the other component.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High voltage power supplies for radar applications are investigated, which are subjected to pulsed load (125 kHz and 10% duty cycle) with stringent specifications (<0.01% regulation, efficiency>85%, droop<0.5 V/micro-sec.). As good regulation and stable operation requires the converter to be switched at much higher frequency than the pulse load frequency, transformer poses serious problems of insulation failure and higher losses. This paper proposes a methodology to tackle the problems associated with this type of application. Synchronization of converter switching with load pulses enables the converter to switch at half the load switching frequency. Low switching frequency helps in ensuring safety of HV transformer insulation and reduction of losses due to skin and proximity effect. Phase-modulated series resonant converter with ZVS is used as the power converter.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A second order transfer function with two poles and two zeros exhibits a step response characterized by a sudden rise to the steady state value, followed by oscillations around this steady state. With proper choice of the coefficients, it is possible to obtain transfer functions suitable for pulse transmission purposes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The modified McMurray Inverter with Pulse Forming Network (PFN) has been explained. The current and voltage waveshapes of the PFN commutation ci rcuit have been compared with conventional L-commutation circuit. The design method of PFN has been explained. Advantages of this type of commutation have been discussed. Experimental results are given.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An in-depth understanding of biological processes often requires detailed atomic resolution structures of the molecules involved. However in solution where most of these processes occur the conformation of biomolecules like RNA, DNA and proteins is not static but fluctuates. Routinely used structural techniques like X-ray crystallography, NMR spectroscopy and cryo-electron microscopy have almost always been used to determine the structure of the dominant conformation or obtain an average structure of the biomolecule in solution with very little detailed information regarding the dynamics of these molecules in solution. Over the last few years, NMR based methods have been developed to study the dynamics of these biomolecules in solution in a site-specific manner with the aim of generating structures of the different conformations that these molecules can adopt in solution. One powerful technique is the Carr-Purcell-Meiboom-Gill (CPMG) relaxation dispersion experiment, which can be used to detect and characterize protein excited states that are populated for as less as 0.5% of the time with ∼0.5–10 millisecond lifetimes. Due to recent advances in NMR pulse sequences and labeling methodology, it is now possible to determine the structures of these transiently populated excited states with millisecond lifetimes by obtaining accurate chemical shifts, residual dipolar couplings (RDCs) and residual chemical shift anisotropies (RCSAs) of these excited states. In these excited states the dynamics of some methyl containing residues can also be studied.