124 resultados para MEMS sensors


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We discuss here a semiconductors assembly comprising of titanium dioxide (TiO2) rods sensitized by cadmium sulfide (CdS) nanocrystals for potential applications in large area electronics on three dimensional (3-D) substrates. Vertically aligned TiO2 rods are grown on a substrate using a 150 degrees C process flow and then sensitized with CdS by SILAR method at room temperature. This structure forms an effective photoconductor as the photo-generated electrons are rapidly removed from the CdS via the TiO2 thereby permitting a hole rich CdS. Current-voltage characteristics are measured and models illustrate space charge limited photo-current as the mechanism of charge transport at moderate voltage bias. The stable assembly and high speed are achieved. The frequency response with a loading of 10 pF and 9 M Omega shows a half power frequency of 100 Hz. (C) 2015 The Electrochemical Society. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The down conversion of radio frequency components around the harmonics of the local oscillator (LO), and its impact on the accuracy of white space detection using integrated spectrum sensors, is studied. We propose an algorithm to mitigate the impact of harmonic downconversion by utilizing multiple parallel downconverters in the system architecture. The proposed algorithm is validated on a test-board using commercially available integrated circuits and a test-chip implemented in a 130-nm CMOS technology. The measured data show that the impact of the harmonic downconversion is closely related to the LO characteristics, and that much of it can be mitigated by the proposed technique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The demand for variety of products and the shorter time to market is encouraging designers to adopt computer aided concept generation techniques. One such technique is being explored here. The present work makes an attempt towards synthesis of concepts for sensors using physical laws and effects as building blocks. A database of building blocks based upon the SAPPhIRE-lite model of causality is maintained. It uses composition to explore the solution space. The algorithm has been implemented in a web based tool. The tool generates two types of sensor designs: direct sensing designs and feedback sensing designs. According to the literature, synthesis using building blocks often lead to vague solutions principles. The current work tries to avoid uninteresting solutions by using some heuristics. A particularly novel outcome of the work described here is the generation of feedback based solutions, something not generated automatically before. A number of patent violations were observed with the set of generated concepts; thus emphasizing some amount of novelty in the designs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ready-to-use screen printed glucose sensors are fabricated using Prussian Blue (PB) and Cobalt Phthalocyanine (CoPC) mediated carbon inks as working electrodes. The reference and counter electrodes are screen printed using silver/silver chloride and graphitic carbon paste respectively. The screen printed reference electrodes (internal reference electrode (IRE)) are found to be stable for more than 60 minutes when examined with saturated calomel electrode. Optimal operating voltage for PB and CoPC screen printed sensors are determined by hydrodynamic voltammetric technique. Glucose oxidase is immobilized on the working electrodes by cross-linking method. PB mediated glucose sensor exhibits a sensitivity of 5.60 mA cm(-2)/mM for the range, 10 to 1000 mu M. Sensitivity of CoPC mediated glucose sensor is found to be 5.224 mu A cm(-2)/mM and amperometeric response is linear for the range, 100 to 1500 mu M. Interference studies on the fabricated glucose sensors are conducted with species like uric acid and ascorbic acid. PB mediated sensors showed a completely interference-free behavior. The sensing characteristics of PB mediated glucose sensors are also studied in diluted human serum samples and the results are compared with the values obtained through standard clinical method. The co-efficient of variation is found to be less than 5%. (C) 2015 The Electrochemical Society. All rights reserved.