218 resultados para Inference Technique
Resumo:
An oscillating droplet method combined with electromagnetic levitation technique has been applied to determine the surface tensions of liquid nickel sulphur alloys as a function of the temperature and composition. The natural frequency of the oscillating droplet is evaluated using a Fourier analyser, and the influence of magnetic field strength on the surface tension was considered. Furthermore, the applicability of Butler's equation and subregular solution model for the surface was shown to predict the surface tension of the systems containing the surface active elements.
Resumo:
A hybrid technique to model two dimensional fracture problems which makes use of displacement discontinuity and direct boundary element method is presented. Direct boundary element method is used to model the finite domain of the body, while displacement discontinuity elements are utilized to represent the cracks. Thus the advantages of the component methods are effectively combined. This method has been implemented in a computer program and numerical results which show the accuracy of the present method are presented. The cases of bodies containing edge cracks as well as multiple cracks are considered. A direct method and an iterative technique are described. The present hybrid method is most suitable for modeling problems invoking crack propagation.
Resumo:
Tin sulfide (SnS) is a material of interest for use as an absorber in low cost solar cells. Single crystals of SnS were grown by the physical vapor deposition technique. The grown crystals were characterized to evaluate the composition, structure, morphology, electrical and optical properties using appropriate techniques. The composition analysis indicated that the crystals were nearly stoichiometric with Sn-to-S atomic percent ratio of 1.02. Study of their morphology revealed the layered type growth mechanism with low surface roughness. The grown crystals had orthorhombic structure with (0 4 0) orientation. They exhibited an indirect optical band gap of 1.06 eV and direct band gap of 1.21 eV with high absorption coefficient (up to 10(3) cm(-1)) above the fundamental absorption edge. The grown crystals were of p-type with an electrical resistivity of 120 Omega cm and carrier concentration 1.52 x 10(15) cm(-3). Analysis of optical absorption and diffuse reflectance spectra showed the presence of a wide absorption band in the wavelength range 300-1200 nm, which closely matches with a significant part of solar radiation spectrum. The obtained results were discussed to assess the suitability of the SnS crystal for the fabrication of optoelectronic devices. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
Gd2O3:Eu3+ (4 mol%) nanophosphor co-doped with Li+ ions have been synthesized by low-temperature solution combustion technique in a short time. Powder X-ray diffractometer (PXRD), scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FT-IR), UV-VIS and photoluminescence (PL) techniques have been employed to characterize the synthesized nanoparticles. It is found that the lattice of Gd2O3:Eu3+ phosphor transforms from monoclinic to cubic as the Li+-ions are doped. Upon 254 nm excitation, the phosphor showed characteristic luminescence D-5(0) -> F-7(J) (J= 0-4) of the Eu3+ ions. The electronic transition located at 626 nm (D-5(0) -> F-7(2)) of Eu3+ ions was stronger than the magnetic dipole transition located at 595 nm (D-5(0) -> F-7(1)). Furthermore, the effects of the Li+ co-doping as well as calcinations temperature on the PL properties have been studied. The results show that incorporation of Li+ ions in Gd2O3:Eu3+ lattice could induce a remarkable improvement of their PL intensity. The emission intensity was observed to be enhanced four times than that of with out Li+-doped Gd2O3:Eu3+. (C) 2010 Elsevier B.V. All rights reserved,
Resumo:
A new method based on analysis of a single diffraction pattern is proposed to measure deflections in micro-cantilever (MC) based sensor probes, achieving typical deflection resolutions of 1nm and surface stress changes of 50 mu N/m. The proposed method employs a double MC structure where the deflection of one of the micro-cantilevers relative to the other due to surface stress changes results in a linear shift of intensity maxima of the Fraunhofer diffraction pattern of the transilluminated MC. Measurement of such shifts in the intensity maxima of a particular order along the length of the structure can be done to an accuracy of 0.01mm leading to the proposed sensitivity of deflection measurement in a typical microcantilever. This method can overcome the fundamental measurement sensitivity limit set by diffraction and pointing stability of laser beam in the widely used Optical Beam Deflection method (OBDM).
Resumo:
When examined using continuous wave electron paramagnetic resonance and nuclear magnetic resonance spectrometers, the high T-c superconductors give rise to intense, low field, 'non-resonant' absorption signals in the superconducting state. This phenomenon can be used as a highly sensitive, contactless technique for the detection and characterization of superconductivity even in samples containing only minute amounts of the superconducting phase. Further, it can also be applied to the determination of material parameters of interest such as J(c) and H-c2 in addition to being a powerful way of distinguishing between weak-link superconductivity and bulk superconductivity. The details of these aspects are discussed
Resumo:
Our ability to infer the protein quaternary structure automatically from atom and lattice information is inadequate, especially for weak complexes, and heteromeric quaternary structures. Several approaches exist, but they have limited performance. Here, we present a new scheme to infer protein quaternary structure from lattice and protein information, with all-around coverage for strong, weak and very weak affinity homomeric and heteromeric complexes. The scheme combines naive Bayes classifier and point group symmetry under Boolean framework to detect quaternary structures in crystal lattice. It consistently produces >= 90% coverage across diverse benchmarking data sets, including a notably superior 95% coverage for recognition heteromeric complexes, compared with 53% on the same data set by current state-of-the-art method. The detailed study of a limited number of prediction-failed cases offers interesting insights into the intriguing nature of protein contacts in lattice. The findings have implications for accurate inference of quaternary states of proteins, especially weak affinity complexes.
Resumo:
The sorting of crystals of (+/-)-4-methoxyphenyl 1-phenylethyl ketone into its enantiomers is facilitated by crystallisation in a cellular grid made of filter paper.
Resumo:
The use of microwave heating technique for the acceleration of ortho ester Claisen rearrangement (a three step transformation) is described. Irradiation of a DMF solution of the allyl alcohol 5, triethyl orthoacetate and propionic acid (catalytic) in an Erlenmeyer flask for 10 minutes in a microwave oven generated the ester 8 in 83% yield. Analogously, ortho ester Claisen rearrangement of a variety of allyl and propargyl alcohols (9, 12-22) were achieved. The formation of the diester 10 from 2-butyne-1,4-diol (9) via the ortho ester Claisen rearrangement of two allyl alcohol moieties (involving sh steps) in 15 minutes, demonstrates the versatility of the microwave heating technique.
Resumo:
The transformation technique is a tool FIR designing 2-D filters, useful for the design of specially shaped filters with passband/stopband regions not centred around the origin. The authors extend this technique to design two types or filters. A notch filter has a stopband centred about a small region in the 2-D frequency plane. The authors propose an extension to the transformation technique with the windowing concept to achieve the design of notch filters. A directional filter has a passband extending fully along: a straight line pacing through the origin. The transformation technique is: further extended to yield such directional filters. Design and application examples for both these fillers are also presented.
Leak Detection In Pressure Tubes Of A Pressurized Heavy-Water Reactor By Acoustic-Emission Technique
Resumo:
Leak detection in the fuel channels is one of the challenging problems during the in-service inspection (ISI) of Pressurised Heavy Water Reactors (PHWRs). In this paper, the use of an acoustic emission (AE) technique together with AE signal analysis is described, to detect a leak that was ncountered in one (or more) of the 306 fuel channels of the Madras Atomic Power Station (PHWR), Unit I. The paper describes the problems encountered during the ISI, the experimental methods adopted and the results obtained. Results obtained using acoustic emission signal analysis are compared with those obtained from other leak detection methods used in such cases.
Resumo:
Tetragonal ZrO2 was synthesized by the solution combustion technique using glycine as the fuel. The compound was characterized by X-ray diffraction, scanning electron microscopy, X-ray photoelectron spectroscopy, infrared spectroscopy, and BET surface area analysis. The ability of this compound to adsorb dyes was investigated, and the compound had a higher adsorption capacity than commercially activated carbon. Infrared spectroscopic observations were used to determine the various interactions and the groups responsible for the adsorption activity of the compound. The effects of the initial concentration of the dye, temperature, adsorbent concentration, and pH of the solution were studied. The kinetics of adsorption was described as a first-order process, and the relative magnitudes of internal and external mass transfer processes were determined. The equilibrium adsorption was also determined and modeled by a composite Langmuir-Freundlich isotherm.
Resumo:
We have developed a technique for precise measurement of small magnetic fields using nonlinear magneto-optic rotation (NMOR). The technique relies on the resonant laser beam being chopped. During the on time, the atoms are optically pumped into an aligned ground state (Delta m=2 coherence). During the off time, they freely precess around the magnetic field at the Larmor frequency. If the on-off modulation frequency matches (twice) the Larmor precession frequency, the rotation is resonantly enhanced in every cycle, thereby making the process like a repeated Ramsey measurement of the Larmor frequency. We study chopped-NMOR in a paraffin-coated Cs vapor cell. The out-of-phase demodulated rotation shows a Lorentzian peak of linewidth 85 mu G, corresponding to a sensitivity of 0.15nG/root Hz. We discuss the potential of this technique for the measurement of an atomic electric-dipole moment. Copyright (C) EPLA, 2011
Resumo:
A new experimental technique is proposed to determine refractive indices of liquids and isotropic solids at different wavelengths. A Pellin-Broca hollow prism filled with a liquid sample produces the spectrum (of the liquid prism) on the photographic plate of the camera. A plane reflector, mounted at a small angle to the normal of the exit face of the prism, also forms a direct image of the collimator slit in the plane of the same photographic plate. All the necessary information for determining the refractive indices (for different wavelengths) is extracted directly from the spectrogram without using any goniometric system. Experiments are conducted with the liquid prisms of isopropyl alcohol, water, and benzene. The results of the experiments are compared with those obtained by a Pulfrich refractometer (critical angle method). The proposed new technique gives the refractive indices for visible and invisible spectral lines to an accuracy of 2x10(-5). (C) 1997 Society of Photo-Optical Instrumentation Engineers.
Resumo:
The statistical performance analysis of ESPRIT, root-MUSIC, minimum-norm methods for direction estimation, due to finite data perturbations, using the modified spatially smoothed covariance matrix, is developed. Expressions for the mean-squared error in the direction estimates are derived based on a common framework. Based on the analysis, the use of the modified smoothed covariance matrix improves the performance of the methods when the sources are fully correlated. Also, the performance is better even when the number of subarrays is large unlike in the case of the conventionally smoothed covariance matrix. However, the performance for uncorrelated sources deteriorates due to an artificial correlation introduced by the modified smoothing. The theoretical expressions are validated using extensive simulations. (C) 1999 Elsevier Science B.V. All rights reserved.