139 resultados para 1303 Specialist Studies in Education
Resumo:
A reduction in the heat losses from the top of the gas holder of a biogas plant has been achieved by the simple device of a transparent cover. The heat losses thus prevented have been deployed to heat a water pond formed on the roof of the gas holder. This solar-heated water is mixed with the organic input for ‘ hot-charging ’ of the biogas plant. A thermal analysis of such a solar water-heater ‘ piggy-backing ’ on the gas holder of a biogas plant has been carried out.To test whether the advantages indicated by the thermal analysis can be realised in practice, a biogas plant of the ASTRA design was modified to incorporate a roof-top solar water-heater. The operation of such a modified plant, even under ‘ worst case ’ onditions, shows a significant improvement in the gas yield compared to the unmodified plant. Hence, the innovation reported here may lead to drastic reductions in the sizes and therefore costs of biogas plants. By making the transparent cover assume a tent-shape, the roof-top solar heater can serve the additional function of a solar still to yield distilled water. The biogas plant-cum-solar water-heater-cum-solar still described here is an example of a spatially integrated hybrid device which is extremely cost-effective.
Resumo:
A thermal model for a conventional biogas plant has been developed in order to understand the heat transfer from the slurry and the gas holder to the surrounding earth and air respectively. The computations have been performed for two conditions : (i) when the slurry is at an ambient temperature of 20°C, and (ii) when it is at 35°C, the optimum temperature for anaerobic fermentation. Under both these conditions, the gas holder is the major “culprit” with regard to heat losses from the biogas plant. The calculations provide an estimate for the heat which has to be supplied by external means to compensate for the net heat losses which occur if the slurry is to be maintained at 35°C. Even if this external supply of heat is realised through (the calorific value of) biogas, there is a net increase in the biogas output, and therefore a net benefit, by operating the plant at 35°C. At this elevated temperature, the cooling effect of adding the influent at ambient temperature is not insignificant. In conclusion, the results of the thermal analysis are used to define a strategy for operating biogas plants at optimum temperatures, or at higher temperatures than the ambient.
Resumo:
In this paper, the design basis of the conventional Khadi and Village Industries Commission biogas plants has been elucidated. It has been shown that minimisation of the cost of the gas holder alone leads to the narrow and deep digesters of conventional plants. If instead, the total capital cost of the gas holder plus digester is minimised, the optimisation leads to wide and shallow digesters, which are less expensive. To test this alternative, two prototype plants have been designed, constructed and operated. These plants are not only 25–40% cheaper, but their performance is actually slightly better than the conventional plants.
Resumo:
This paper gives an account of a conventional 5.66 m3/day (200 cubic ft/day) biogas plant which has been instrumented, operated and monitored for 2 1/2 years. The observations regarding input to the plant, sludge and biogas outputs, and conditions inside the digester, have been described. Three salient features stand out. First, the observed average daily gas yield is much less than the rated capacity of the plant. Secondly, the plants show ease of operation and a very slow response to reductions and cessations of dung supply. Thirdly, the unexpectedly marked uniformity of density and temperature inside the digester indicates the almost complete absence of the stratification which is widely believed to take place; hence, biogas plants may be treated as isothermal, ‘ uniform ’ density, most probably imperfectly mixed, fed-batch reactors operating at the mean ambient temperature and the density of water.
Resumo:
Alkali metal perchlorates (KClO4, RbClO4, and CsClO4) undergo a structural phase transition from the orthorhombic to the cubic phase at elevated temperatures. A detailed dielectric study of these crystals across the phase transition is carried out at different frequencies. The crystals are found to exhibit pronounced dielectric dispersion in the kHz frequency range. The results support the view that these transitions are of order–disorder type. The dielectric behaviour at temperatures above Tc is discussed in terms of modulus spectroscopy. An estimate of conductivity relaxation times above the phase transition temperatures made from modulus spectroscopy data gives values of 3.1, 12.2 and 17.7 μs for KClO4, RbClO4, and CsClO4, respectively.
Resumo:
A generalized two‐dimensional flow‐radiation coupled model to extract power from a gasdynamic laser is proposed. The model is used for the study of power extraction from a 9.4‐μm CO2 downstream‐mixing gasdynamic laser, where a cold CO2+H2 stream is mixed with a vibrationally excited N2 stream at the nozzle exits. This model is developed by coupling radiation with the two‐dimensional, unsteady, laminar and viscous flow modeling needed for such systems. The analysis showed that the steady‐state value of 9.4‐μm intensity as high as 5×107 W/m2 can be obtained from the system studied. The role of H2 relaxant in the power extraction process has also been investigated.
Resumo:
Studies in crystal engineering. Photochemical and crystallographic investigations of bromocoumarins and (±)-7-(p-bromobenzylidene)piperitone