89 resultados para microcantilever sensors


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work considers the identification of the available whitespace, i.e., the regions that do not contain any existing transmitter within a given geographical area. To this end, n sensors are deployed at random locations within the area. These sensors detect for the presence of a transmitter within their radio range r(s) using a binary sensing model, and their individual decisions are combined to estimate the available whitespace. The limiting behavior of the recovered whitespace as a function of n and r(s) is analyzed. It is shown that both the fraction of the available whitespace that the nodes fail to recover as well as their radio range optimally scale as log(n)/n as n gets large. The problem of minimizing the sum absolute error in transmitter localization is also analyzed, and the corresponding optimal scaling of the radio range and the necessary minimum transmitter separation is determined.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tin oxide nanoparticles are synthesized using solution combustion technique and tin oxide - carbon composite thick films are fabricated with amorphous carbon as well as carbon nanotubes (CNTs). The x-ray diffraction, Raman spectroscopy and porosity measurements show that the as-synthesized nanoparticles are having rutile phase with average crystallite size similar to 7 nm and similar to 95 m(2)/g surface area. The difference between morphologies of the carbon doped and CNT doped SnO2 thick films, are characterized using scanning electron microscopy and transmission electron microscopy. The adsorption-desorption kinetics and transient response curves are analyzed using Langmuir isotherm curve fittings and modeled using power law of semiconductor gas sensors. (C) 2015 Author(s).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Surface electrodes in Electrical Impedance Tomography (EIT) phantoms usually reduce the SNR of the boundary potential data due to their design and development errors. A novel gold sensors array with high geometric precision is developed for EIT phantoms to improve the resistivity image quality. Gold thin films are deposited on a flexible FR4 sheet using electro-deposition process to make a sixteen electrode array with electrodes of identical geometry. A real tissue gold electrode phantom is developed with chicken tissue paste and the fat cylinders as the inhomogeneity. Boundary data are collected using a USB based high speed data acquisition system in a LabVIEW platform for different inhomogeneity positions. Resistivity images are reconstructed using EIDORS and compared with identical stainless steel electrode systems. Image contrast parameters are calculated from the resistivity matrix and the reconstructed images are evaluated for both the phantoms. Image contrast and image resolution of resistivity images are improved with gold electrode array.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper demonstrates the role of solvent in selectivity and sensitivity of a series of electron-rich compounds for the detection of trace amounts of picric acid. Two new electron-rich fluorescent esters (6, 7) containing a triphenylamine backbone as well as their analogous carboxylic acids (8, 9) have been synthesized and characterized. Fluorescent triphenylamine coupled with an ethynyl moiety constitutes p-electron-rich selective and sensitive probes for electron-deficient picric acid (PA). In solution, the high sensitivity of all the sensors toward PA can be attributed to a combined effect of the ground-state charge-transfer complex formation and resonance energy transfer between the sensor and analyte. The acids 8 and 9 also showed enhanced sensitivity for nitroaromatics in the solid state, and their enhanced sensitivity could be attributed to exciton migration due to close proximity of the neighboring acid molecules, as evident from the X-ray diffraction study. The compounds were found to be quite sensitive for the detection of trace amount of nitroaromatics in solution, solid, and contact mode.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Novel imine functionalized monometallic rhenium(I) polypyridine complexes (1-4) comprising two phenol moieties attached to 2,20-bipyridine ligands L1-L4 have been synthesized and characterized. These complexes exhibit selective and sensitive detection towards copper(II) ions and this is observed through changes in UV-visible absorption, luminescence and time-resolved spectroscopic techniques. An enormous enhancement is observed in emission intensity, quantum yield and luminescence lifetime with the addition of copper(II) ions, and this can be attributed to the restriction of C=N isomerization in the Re(I) complexes. The strong binding between copper(II) ions and these complexes reveals that the binding constant values are in the range of 1.1 x 10(3)-6.0 x 103 M-1. The absorption spectral behavior of the complexes is supported by DFT calculations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ionic polymer metal composites (IPMC) actuator for flapping insect scale wing is advantageous due to its low mass, high deflection and simple actuation mechanism. Some of the factors that affect the actuation of IPMC are the amount of hydration in the polymer membrane and the environmental conditions such as temperature, humidity etc. In structural design, the attachment of wing on the IPMC actuators is an important concern as the attached wing increases the mass of actuators thereby affecting the parameters like displacement, stiffness and resonant frequencies. Such IPMC actuators have to produce sufficient actuation force and frequency to lift and flap the attached wing. Therefore, it is relevant to study the influence of attachment of wing on the actuator parameters (displacement, resonant frequency, block force and stiffness) and performance of the actuators. This paper is divided into two parts; the first part deals with the modeling of the IPMC actuators for its effect on the level of water uptake and temperature using energy based method. The modeling method adapted is validated with the experimental procedure used to actuate the IPMC. The second part deals with the experimental analysis of IPMC actuation at dry, wet and in water conditions. The effect of end mass loading on the performance of 20 Hz, high frequency actuator (HFA) and 8.7 Hz, low frequency IPMC actuators (LFA) and sensors is studied. The IPMC actuators are attached with IPMC flapping wing at its free end and performance analysis on the attached wing is also carried out.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A temperature compensation method is proposed for CNT-composite strain sensors. CNT-composite sensors are fabricated on an elastic polymer substrate having known thermo-mechanical properties to introduce thermo-mechanical strain and further calibration of the sensor. Strain is induced on the sensor by bending the substrate as a cantilever configuration. Response of the sensor is measured using a bridge circuit method. Induced strain in the beam is determined using beam theory. The sensors are characterized for different CNT concentrations and at various temperatures. A model based temperature compensation scheme is proposed and verified experimentally. The result proves the ability of CNT-nanocomposite strain sensors to be used under varying temperature applications. A method is proposed to determine the strain and temperature simultaneously. The CNT sensors are simple to fabricate in complex patterns with excellent repeatability and do not require bonding layer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A real-time cooperative localization system, utilizing dual foot-mounted low-cost inertial sensors and RF-based inter-agent ranging, has been developed. Scenario-based tests have been performed, using fully-equipped firefighters mimicking a search operation in a partly smoke-filled environment, to evaluate the performance of the TOR (Tactical lOcatoR) system. The performed tests included realistic firefighter movements and inter-agent distances, factors that are crucial in order to provide realistic evaluations of the expected performance in real-world operations. The tests indicate that the TOR system may be able to provide a position accuracy of approximately two to three meters during realistic firefighter operations, with only two smoke diving firefighters and one supervising firefighter within range.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One of the most interesting predicted applications of graphenemonolayer-based devices is as high-quality sensors. In this article, we show, through systematic experiments, a chemical vapor sensor based on the measurement of lowfrequency resistance fluctuations of single-layer-graphene field-effect-transistor devices. The sensor has extremely high sensitivity, very high specificity, high fidelity, and fast response times. The performance of the device using this scheme of measurement (which uses resistance fluctuations as the detection parameter) is more than 2 orders of magnitude better than a detection scheme in which changes in the average value of the resistance is monitored. We propose a number-densityfluctuation-based model to explain the superior characteristics of a noisemeasurement-based detection scheme presented in this article.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Selective and discriminative detection of -NO2 containing high energy organic compounds such as picric acid (PA), 2,4,6-trinitrotoluene (TNT) and dinitrotoluene (DNT) has become a challenging task due to concerns over national security, criminal investigations and environment protections. Among various known detection methods, fluorescence techniques have gained special attention in recent time. A wide variety of fluorescent chemosensors have been developed for nitroaromatic explosive detection. In this review article, we provide an overview of the recent developments made in small molecule-based turn-off fluorescent sensors for nitroaromatic explosives with special focus on organic and H-bonded supramolecular sensors. The fluorescent sensors discussed in this review are classified and organized according to their functionality and their recognition of nitroaromatics by fluorescence quenching.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We discuss here a semiconductors assembly comprising of titanium dioxide (TiO2) rods sensitized by cadmium sulfide (CdS) nanocrystals for potential applications in large area electronics on three dimensional (3-D) substrates. Vertically aligned TiO2 rods are grown on a substrate using a 150 degrees C process flow and then sensitized with CdS by SILAR method at room temperature. This structure forms an effective photoconductor as the photo-generated electrons are rapidly removed from the CdS via the TiO2 thereby permitting a hole rich CdS. Current-voltage characteristics are measured and models illustrate space charge limited photo-current as the mechanism of charge transport at moderate voltage bias. The stable assembly and high speed are achieved. The frequency response with a loading of 10 pF and 9 M Omega shows a half power frequency of 100 Hz. (C) 2015 The Electrochemical Society. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The down conversion of radio frequency components around the harmonics of the local oscillator (LO), and its impact on the accuracy of white space detection using integrated spectrum sensors, is studied. We propose an algorithm to mitigate the impact of harmonic downconversion by utilizing multiple parallel downconverters in the system architecture. The proposed algorithm is validated on a test-board using commercially available integrated circuits and a test-chip implemented in a 130-nm CMOS technology. The measured data show that the impact of the harmonic downconversion is closely related to the LO characteristics, and that much of it can be mitigated by the proposed technique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The demand for variety of products and the shorter time to market is encouraging designers to adopt computer aided concept generation techniques. One such technique is being explored here. The present work makes an attempt towards synthesis of concepts for sensors using physical laws and effects as building blocks. A database of building blocks based upon the SAPPhIRE-lite model of causality is maintained. It uses composition to explore the solution space. The algorithm has been implemented in a web based tool. The tool generates two types of sensor designs: direct sensing designs and feedback sensing designs. According to the literature, synthesis using building blocks often lead to vague solutions principles. The current work tries to avoid uninteresting solutions by using some heuristics. A particularly novel outcome of the work described here is the generation of feedback based solutions, something not generated automatically before. A number of patent violations were observed with the set of generated concepts; thus emphasizing some amount of novelty in the designs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ready-to-use screen printed glucose sensors are fabricated using Prussian Blue (PB) and Cobalt Phthalocyanine (CoPC) mediated carbon inks as working electrodes. The reference and counter electrodes are screen printed using silver/silver chloride and graphitic carbon paste respectively. The screen printed reference electrodes (internal reference electrode (IRE)) are found to be stable for more than 60 minutes when examined with saturated calomel electrode. Optimal operating voltage for PB and CoPC screen printed sensors are determined by hydrodynamic voltammetric technique. Glucose oxidase is immobilized on the working electrodes by cross-linking method. PB mediated glucose sensor exhibits a sensitivity of 5.60 mA cm(-2)/mM for the range, 10 to 1000 mu M. Sensitivity of CoPC mediated glucose sensor is found to be 5.224 mu A cm(-2)/mM and amperometeric response is linear for the range, 100 to 1500 mu M. Interference studies on the fabricated glucose sensors are conducted with species like uric acid and ascorbic acid. PB mediated sensors showed a completely interference-free behavior. The sensing characteristics of PB mediated glucose sensors are also studied in diluted human serum samples and the results are compared with the values obtained through standard clinical method. The co-efficient of variation is found to be less than 5%. (C) 2015 The Electrochemical Society. All rights reserved.