207 resultados para Evacuated tube


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Color displays used in image processing systems consist of a refresh memory buffer storing digital image data which are converted into analog signals to display an image by driving the primary color channels (red, green, and blue) of a color television monitor. The color cathode ray tube (CRT) of the monitor is unable to reproduce colors exactly due to phosphor limitations, exponential luminance response of the tube to the applied signal, and limitations imposed by the digital-to-analog conversion. In this paper we describe some computer simulation studies (using the U*V*W* color space) carried out to measure these reproduction errors. Further, a procedure to correct for color reproduction error due to the exponential luminance response (gamma) of the picture tube is proposed, using a video-lookup-table and a higher resolution digital-to-analog converter. It is found, on the basis of computer simulation studies, that the proposed gamma correction scheme is effective and robust with respect to variations in the assumed value of the gamma.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The laminar flow of a fairly concentrated suspension (in which the volume fraction Z of the solid particles < 0.4) in a spatially varying periodically curved pipe has been examined numerically. Unlike the case of interacting suspension flows, the particles are found to flow in a well-mixed fashion, altering both the axial and circumferential velocities and consequently the fluid flux in the tube, depending on their diffusivity and inertia. The magnitude of shear stress at the wall is enhanced, suggesting that, if applied to vascular system, the vascular wall could be prone to ulceration during pathological situations like polycythemia. The delay in adaptation of the deviation in Poiseuille flow velocity to the curvature changes is also discussed in detail.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The electrical and optical properties of the thermally induced quenched-in levels in p-silicon which have heen attributed to iron are studied. The two levels, HI and H2, are located at Ev + 0.42 eV and Ev + 0.52 eV, respectively, as determined by TSCAP, DLTS, and transient photocapacitance methods. The photoionization cross sections are well described by Lucovsky's model. The hole capture by H1 is temperature dependent; a barrier of 40 meV is measured. However, multiphonon emission mechanism cannot be invoked to explain this temperature dependence due to the inferred zero lattice relaxation. The source of iron contamination is found to be the ambient conditions, in particular the quartz tube. The conflicting reports regarding the stability and the variation in the reported capture cross section values suggests that the observed Ev + 0.4 eV level must be a complex centre. The inferred near zero lattice relaxation during the electron transition implies weak coupling to the host lattice.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A mathematical model for pulsatile flow in a partially occluded tube is presented. The problem has applications in studying the effects of blood flow characteristics on atherosclerotic development. The model brings out the importance of the pulsatility of blood flow on separation and the stress distribution. The results obtained show fairly good agreement with the available experimental results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple mathematical model depicting blood flow in the capillary is developed with an emphasis on the permeability property of the blood vessel based on Starling's hypothesis. In this study the effect of inertia has been neglected in comparison with the viscosity on the basis of the smallness of the Reynolds number of the flow in the capillary. The capillary blood vessel is approximated by a circular cylindrical tube with a permeable wall. The blood is represented by a couple stress fluid. With such an ideal model the velocity and pressure fields are determined. It is shown that an increase in the couple stress parameter increases the resistance to the flow and thereby decreases the volume rate flow. A comparison of the results with those of the Newtonian case has also been made.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The hydrodynamical problem of flow in proximal renal tubule is investigated by considering axisymmetric flow of a viscous, incompressible fluid through a long narrow tube of varying cross-section with reabsorption at the wall. Two cases for reabsorption have been studied (i) when the bulk flow,Q, decays exponentially with the axial distancex, and (ii) whenQ is an arbitrary function ofx such thatQ-Q 0 can be expressed as a Fourier integral (whereQ 0 is the flux atx=0). The analytic expressions for flow variables have been obtained by applying perturbation method in terms of wall parameter ε. The effects of ε on pressure drop across the tube, radial velocity and wall shear have been studied in the case of exponentially decaying bulk flow and it has been found that the results are in agreement with the existing ones for the renal tubules.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It is shown that Tl2Ca2Ba2Cu3O10+δ (2223), the n=3 member of the Tl2O2. Can�1Ba2CunO2n+2 family shows a Tc (zero-resistance) of 125K (onset 140K) only when it is prepared by the sealed tube ceramic method starting from the 1313 composition. The structure is orthorhombic (Image compared to 30� of 2122), but electron diffraction patterns show two possible orthorhombic structures. Lattice images show the expected local structure and also the presence of dislocations and intergrowths. Both 2223 and 2122 oxides absorb microwaves (9.1GHz) intensely in the superconducting state, with some hysteresis. XPS measurements show Cu mainly in the 1+ state, suggesting the important role of oxygen holes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The pulsatile flow of an incompressible viscous fluid in a cylindrical tube of varying cross section is investigated for small Reynolds numbers. The solutions consist of a stedy and an oscillatory part. The shear stress distribution on the wall is evaluated and discussed in detail for special geometries like tapered tubes, locally constricted tubes and peristaltic tubes. The existence of separation in the flow field is noticed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aqueous solutions of sodium chloride were solidified under the influence of magnetic and electrical fields using two different freezing systems. In the droplet system, small droplets of the solution are introduced in an organic liquid column at −20°C which acts as the heat sink. In the unidirectional freezing system the solutions are poured into a tygon tube mounted on a copper chill, maintained at −70°C, from which the freezing initiates. Application of magnetic fields caused an increase in the spacing and promoted side branching of primary ice dendrites in the droplet freezing system, but had no measurable effect on the dendrites formed in the unidirectional freezing system. The range of electric fields applied in this investigation had no measurable effect on the dendritic structure. Possible interactions between external magnetic and electrical fields have been reviewed and it is suggested that the selective effect of magnetic fields on dendrite spacings in a droplet system could be due to a change in the nucleation behaviour of the solution in the presence of a magnetic field.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The development of a highly sensitive liquid bubble manometer which can measure low differential heads to an accuracy of 0.01 mm of water is reported in this paper. The liquid bubble consists of two miscible liquids,benzaldehyde and normal hexane (each of which is immiscible in water) in such a proportion that the bubble density is within ±2 % of the density of water. The movement of the liquid bubble, which occupies the full cross-sectional area of the glass tube containing water in the manometer, is indicative of the applied differential head to a magnified scale. The manometer is found to give excellent results in open channel flow and is recommended for use for differential heads up to 2 cm of water. The manometer is economical, simple in fabrication and with simple modifications the sensitivity of the manometer can be increased to more than 0.01 mm of water.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Explosive driven micro blast waves are generated in the laboratory using NONEL tubes. The explosive mixture coated to the inner walls of the plastic Nonel tube comprises of HMX and Aluminum ( 18mg/m). The detonation is triggered electrically to generate micro blast waves from the open end of the tube. Flow visualization and over pressure measurements have been carried out to understand the propagation dynamics of these micro-blast waves in both confined and unconfined domains. The classical cubic root law used for large scale blast correlation appears to hold good even for these micro-blasts generated in the laboratory.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Interaction of shock heated test gas in the free piston driven shock tube with bulk and thin film of cubic zirconium dioxide (ZrO2) prepared by combustion method is investigated. The test samples before and after exposure to the shock wave are analyzed by X-ray diffraction (XRD), X-Ray Photoelectron Spectroscopy (XPS) and Scanning Electron Microscope (SEM). The study shows transformation of metastable cubic ZrO2 to stable monoclinic ZrO2 phase after interacting with shock heated oxygen gas due to the heterogeneous catalytic recombination surface reaction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

NONEL tube finds vast applications in civil and military because of its safe and confined explosion technique. Spectroscopic and chemical analysis of a NONEL tube with an uniform mixture of HMX and Al is reported here. Peak temperature obtained at the open end of the NONEL tube due to the detonation of the explosive has been calculated using Planck’s radiation law. The products of the chemical reaction taking place due to the ignition of HMX + Al are characterized using FTIR spectroscopy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Single pulse shock tube facility has been developed in the High Temperature Chemical Kinetics Lab, Aerospace Engineering Department, to carry out ignition delay studies and spectroscopic investigations of hydrocarbon fuels. Our main emphasis is on measuring ignition delay through pressure rise and by monitoring CH emission for various jet fuels and finding suitable additives for reducing the delay. Initially the shock tube was tested and calibrated by measuring the ignition delay of C2H6-O2 mixture. The results are in good agreement with earlier published works. Ignition times of exo-tetrahdyrodicyclopentadiene (C10H16), which is a leading candidate fuel for scramjet propulsion has been studied in the reflected shock region in the temperature range 1250 - 1750 K with and without adding Triethylamine (TEA). Addition of TEA results in substantial reduction of ignition delay of C10H16.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An analytical solution is presented for the laminar swirling flow in a tube. Attention is given to a particular type of swirling flow corresponding to a zero longitudinal acceleration parameter, with large suction at the surface. The investigation shows that in the case of very large rates of suction the velocity overshoot can be almost eliminated. This is even possible in flows with swirls which are characterized by a velocity overshoot in the longitudinal direction.