103 resultados para DISTRIBUCIÓN VERTICAL DE TREMPERATURA


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, we present field emission characteristics of multi-wall carbon nanotube (MWCNT)-polystyrene composites at various weight fractions along the cross-section of sample. Scanning electron microscope images in cross-sectional view reveal that MWCNTs are homogeneously distributed across the thickness and the density of protruding tubes can be scaled with weight fraction of the composite film. Field emission from composites has been observed to vary considerably with density of MWCNTs in the polymer matrix. High current density of 100 mA/cm(2) was achieved at a field of 2.2 V/lm for 0.15 weight fraction. The field emission is observed to follow the Fowler-Nordheim tunneling mechanism, however, electrostatic screening is observed to play a role in limiting the current density at higher weight fractions. (C) 2012 American Institute of Physics. [doi:10.1063/1.3685754]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In species-rich assemblages, differential utilization of vertical space can be driven by resource availability. For animals that communicate acoustically over long distances under habitat-induced constraints, access to an effective transmission channel is a valuable resource. The acoustic adaptation hypothesis suggests that habitat acoustics imposes a selective pressure that drives the evolution of both signal structure and choice of calling sites by signalers. This predicts that species-specific signals transmit best in native habitats. In this study, we have tested the hypothesis that vertical stratification of calling heights of acoustically communicating species is driven by acoustic adaptation. This was tested in an assemblage of 12 coexisting species of crickets and katydids in a tropical wet evergreen forest. We carried out transmission experiments using natural calls at different heights from the forest floor to the canopy. We measured signal degradation using 3 different measures: total attenuation, signal-to-noise ratio (SNR), and envelope distortion. Different sets of species supported the hypothesis depending on which attribute of signal degradation was examined. The hypothesis was upheld by 5 species for attenuation and by 3 species each for SNR and envelope distortion. Only 1 species of 12 provided support for the hypothesis by all 3 measures of signal degradation. The results thus provided no overall support for acoustic adaptation as a driver of vertical stratification of coexisting cricket and katydid species.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The vertical uplift resistance for a group of two horizontal coaxial rigid strip anchors embedded in clay under undrained condition has been determined by using the upper bound theorem of limit analysis in combination with finite elements. An increase of undrained shear strength of soil mass with depth has been incorporated. The uplift factor F-c gamma has been computed. As compared to a single isolated anchor, a group of two anchors provides greater magnitude of the uplift resistance. For a given embedment ratio, the group of two anchors generates almost the maximum uplift resistance when the upper anchor is located midway between ground surface and the lower anchor. For a given embedment ratio, F-c gamma increases linearly with an increase in the normalized unit weight of soil mass up to a certain value before attaining a certain maximum magnitude; the maximum value of F-c gamma increases with an increase in embedment ratio. DOI: 10.1061/(ASCE)GT.19435606.0000599. (C) 2012 American Society of Civil Engineers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Study of laminar boundary layer in mixed convection from vertical plates is carried out. The surface temperature along the vertical plate is assumed to vary arbitrarily with vertical distance. Perturbation technique is used to solve the governing boundary layer equations. The differentials of the wall temperature are used as perturbation elements, which are functions of vertical distance, to obtain universal functions. The universal functions are valid for any type of vertical wall temperature variation. Heat transfer rates and fluid velocity inside the boundary layer can be expressed and calculated using these universal functions. Heat transfer rates are obtained for the special cases of power-law variation of the wall temperature. The effect of the governing parameter (Gr(y)/Re-y(2)) and the power index of the power-law wall temperature variation on heat transfer rates is studied. For the purpose of validation, the mixed convection results obtained by the present technique pertaining to the special cases of isothermal vertical wall are compared with those obtained by similarity analysis reported in literature, and the agreement is found to be good. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three-dimensional numerical study of natural convection in a vertical channel with flush-mounted discrete heaters on opposite conductive substrate walls is carried out in the present work. Detailed flow and heat transfer characteristics are presented for various Grashof numbers. The heat transfer effects on one wall by the presence of heaters on its opposite wall is examined. It is found that heat transfer rates on one wall are increased by the presence of heaters on its opposite wall. The thermal boundary layers on the opposite walls complement each other for enhanced heat transfer. The effects of spacing between the heated walls, spacings between heaters and substrate conductivity on flow and heat transfer are examined. Existence of optimum spacings between the heated walls for maximum heat transfer and mass flow are observed. It is found that the heat transfer and fluid flow do not follow the same optimum spacings. Mass flow rate reaches maximum value at a wall spacing greater than the spacing for maximum heat transfer. This is because the interaction of thermal boundary layers on individual walls ceases at a lower spacing before the velocity boundary layers separate each other. It is found that increased spacings between heaters reduce individual heater temperatures provided the heaters close to exit on both substrates avail sufficient substrate potions on the exit side. Insufficient substrate portions between the exit heaters and the exit cause abnormal local temperature rise in the exit heaters which are the hottest ones among all the heaters. Optimal heater spacings exist for minimum hottest heater temperature rise. Correlations are presented for dimensionless mass flow rate, temperature maximum, and average Nusselt number.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Laminar natural convection between two coaxial vertical rectangular cylinders is numerically studied in this work. The outer cylinder is connected with vertical rectangular inlet and outlet pipes. The inner cylinder dissipates volumetric heat. The fluid flow and heat transfer characteristics between the cylinders are analyzed in detail for various Grashof numbers. The heat transfer rates on the individual faces of the inner cylinder are reported. The bottom face of the inner cylinder is found to associate with much higher heat rates than those of the other faces. The average Nusselt number on bottom face is more than 2.5 times of the Nusselt number averaged on all the faces. At a given elevation, local Nusselt number on the inner cylinder faces increases towards cylinder edges. The effect of thermal condition of the walls of outer cylinder, inlet and outlet on the natural convection is analyzed. The thermal condition shows strong qualitative and quantitative impact on the fluid flow and heat transfer. The variation of induced flow rate, dimensionless maximum temperature and average Nusselt numbers with Grashof number is studied. Correlations for dimensionless buoyancy-induced mass flow rate and temperature maximum are presented. (c) 2012 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Precise specification of the vertical distribution of cloud optical properties is important to reduce the uncertainty in quantifying the radiative impacts of clouds. The new global observations of vertical profiles of clouds from the CloudSat mission provide opportunities to describe cloud structures and to improve parameterization of clouds in the weather and climate prediction models. In this study, four years (2007-2010) of observations of vertical structure of clouds from the CloudSat cloud profiling radar have been used to document the mean vertical structure of clouds associated with the Indian summer monsoon (ISM) and its intra-seasonal variability. Active and break monsoon spells associated with the intra-seasonal variability of ISM have been identified by an objective criterion. For the present analysis, we considered CloudSat derived column integrated cloud liquid and ice water, and vertically profiles of cloud liquid and ice water content. Over the South Asian monsoon region, deep convective clouds with large vertical extent (up to 14 km) and large values of cloud water and ice content are observed over the north Bay of Bengal. Deep clouds with large ice water content are also observed over north Arabian Sea and adjoining northwest India, along the west coast of India and the south equatorial Indian Ocean. The active monsoon spells are characterized by enhanced deep convection over the Bay of Bengal, west coast of India and northeast Arabian Sea and suppressed convection over the equatorial Indian Ocean. Over the Bay of Bengal, cloud liquid water content and ice water content is enhanced by similar to 90 and similar to 200 % respectively during the active spells. An interesting feature associated with the active spell is the vertical tilting structure of positive CLWC and CIWC anomalies over the Arabian Sea and the Bay of Bengal, which suggests a pre-conditioning process for the northward propagation of the boreal summer intra-seasonal variability. It is also observed that during the break spells, clouds are not completely suppressed over central India. Instead, clouds with smaller vertical extent (3-5 km) are observed due to the presence of a heat low type of circulation. The present results will be useful for validating the vertical structure of clouds in weather and climate prediction models.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fastest curve-fitting procedures are proposed for vertical and radial consolidations for rapid loading methods. In vertical consolidation, the next load increment can be applied at 50-60% consolidation (or even earlier if the compression index is known). In radial consolidation, the next load increment can be applied at just 10-15% consolidation. The effects of secondary consolidation on the coefficient of consolidation and ultimate settlement are minimized in both cases. A quick procedure is proposed in vertical consolidation that determines how far is calculated from the true , where is coefficient of consolidation. In radial consolidation no such procedure is required because at 10-15% the consolidation effects of secondary consolidation are already less in most inorganic soils. The proposed rapid loading methods can be used when the settlement or time of load increment is not known. The characteristic features of vertical, radial, three-dimensional, and secondary consolidations are given in terms of the rate of settlement. A relationship is proposed between the coefficient of the vertical consolidation, load increment ratio, and compression index. (C) 2013 American Society of Civil Engineers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The horizontal pullout capacity of a group of two vertical strip plate anchors, placed along the same vertical plane, in a fully cohesive soil has been computed by using the lower bound finite element limit analysis. The effect of spacing between the plate anchors on the magnitude of total group failure load (P-uT) has been evaluated. An increase of soil cohesion with depth has also been incorporated in the analysis. For a weightless medium, the total pullout resistance of the group becomes maximum corresponding to a certain optimum spacing between the anchor plates which has been found to vary generally between 0.5B and B; where B is the width of the anchor plate. As compared to a single plate anchor, the increase in the pullout resistance for a group of two anchors becomes greater at a higher embedment ratio. The effect of soil unit weight has also been analyzed. It is noted that the interference effect on the pullout resistance increases further with an increase in the unit weight of soil mass.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The horizontal pullout capacity of a group of two vertical strip anchors placed along the same vertical plane in sand has been determined by using the upper bound finite elements limit analysis. The variation of the efficiency factor (xi (gamma) ) with changes in clear spacing (S) between the anchors has been established to evaluate the total group failure load for different values of (i) embedment ratio (H/B), (ii) soil internal friction angle (phi), and (iii) anchor-soil interface friction angle (delta). The total group failure load, for a given H/B, becomes always maximum corresponding to a certain optimal spacing (S-opt). The value of S-opt/B was found to lie in a range of 0.5-1.4. The maximum magnitude of xi (gamma) increases generally with increases in H/B, phi and delta.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We demonstrate the efficacy of amorphous macroporous carbon substrates as electrodes to support neuronal cell proliferation and differentiation in electric field mediated culture conditions. The electric field was applied perpendicular to carbon substrate electrode, while growing mouse neuroblastoma (N2a) cells in vitro. The placement of the second electrode outside of the cell culture medium allows the investigation of cell response to electric field without the concurrent complexities of submerged electrodes such as potentially toxic electrode reactions, electro-kinetic flows and charge transfer (electrical current) in the cell medium. The macroporous carbon electrodes are uniquely characterized by a higher specific charge storage capacity (0.2 mC/cm(2)) and low impedance (3.3 k Omega at 1 kHz). The optimal window of electric field stimulation for better cell viability and neurite outgrowth is established. When a uniform or a gradient electric field was applied perpendicular to the amorphous carbon substrate, it was found that the N2a cell viability and neurite length were higher at low electric field strengths (<= 2.5 V/cm) compared to that measured without an applied field (0 V/cm). While the cell viability was assessed by two complementary biochemical assays (MTT and LDH), the differentiation was studied by indirect immunostaining. Overall, the results of the present study unambiguously establish the uniform/gradient vertical electric field based culture protocol to either enhance or to restrict neurite outgrowth respectively at lower or higher field strengths, when neuroblastoma cells are cultured on porous glassy carbon electrodes having a desired combination of electrochemical properties. (C) 2013 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The vertical uplift resistance of two closely spaced horizontal strip plate anchors has been investigated by using lower and upper bound theorems of the limit analysis in combination with finite elements and linear optimization. The interference effect on uplift resistance of the two anchors is evaluated in terms of a nondimensional efficiency factor (eta(c)). The variation of eta(c) with changes in the clear spacing (S) between the two anchors has been established for different combinations of embedment ratio (H/B) and angle of internal friction of the soil (phi). An interference of the anchors leads to a continuous reduction in uplift resistance with a decrease in spacing between the anchors. The uplift resistance becomes a minimum when the two anchors are placed next to each other without any gap. The critical spacing (S-cr) between the two anchors required to eliminate the interference effect increases with an increase in the values of both H/B and phi. The value of S-cr was found to lie approximately in the range 0.65B-1.5B with H/B = 1 and 11B-14B with H/B = 7 for phi varying from 0 degrees to 30 degrees.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With an application of the upper bound finite element limit analysis, the vertical pullout capacity of a group of two horizontal strip plate anchors, with the common vertical axis and placed in a cohesive-frictional soil, has been computed. The variation of the uplift factors Fc, Fq and Fy, due to the contributions of soil cohesion, surcharge pressure and unit weight, respectively, has been evaluated for different combinations of S/B and H/B. As compared to single isolated anchor, the group of two anchors generates significantly greater magnitude of Fc for Φ ≤ 20° especially with greater values of H/B and under fully bonded anchor-soil interface condition. The factor Fc attains almost the maximum value when the upper anchor plate is placed midway between ground surface and the lower anchor plate. The factors Fq and Fy, on the other hand, for a group of two anchors are found to remain almost equal to that of a single isolated anchor as long as the levels of the lower plate in the group and the single isolated anchor are kept the same.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The horizontal pullout capacity of vertical anchors embedded in sand has been determined by using an upper bound theorem of the limit analysis in combination with finite elements. The numerical results are presented in nondimensional form to determine the pullout resistance for various combinations of embedment ratio of the anchor (H/B), internal friction angle (ϕ) of sand, and the anchor-soil interface friction angle (δ). The pullout resistance increases with increases in the values of embedment ratio, friction angle of sand and anchor-soil interface friction angle. As compared to earlier reported solutions in literature, the present solution provides a better upper bound on the ultimate collapse load.