143 resultados para Cooling ponds


Relevância:

10.00% 10.00%

Publicador:

Resumo:

We discuss two temperature accretion disk flows around rotating black holes. As we know that to explain observed hard X-rays the choice of Keplerian angular momentum profile is not unique, we consider the sub-Keplerian regime of the disk. Without any strict knowledge of the magnetic field structure, we assume the cooling mechanism is dominated by bremsstrahlung process. We show that in a range of Shakura-Sunyaev viscosity parameter 0.2 greater than or similar to alpha greater than or similar to 0.0005, flow behavior varies widely, particularly by means of the size of disk, efficiency of cooling and corresponding temperatures of ions and electrons. We also show that the disk around a rotating black hole is hotter compared to that around a Schwarzschild black hole, rendering a larger difference between ion and electron temperatures in the former case. With all the theoretical solutions in hand, finally we reproduce the observed luminosities (L) of two extreme cases-the under-fed AGNs and quasars (e.g. Sgr A') with L greater than or similar to 10(33) erg/s to ultra-luminous X-ray sources with L similar to 10(41) erg/s, at different combinations of mass accretion rate, ratio of specific heats, Shakura-Sunyaev viscosity parameter and Kerr parameter, and conclude that Sgr A' may be an intermediate spinning black hole.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The first finding of low-temperature eclogites from the Indochina region is reported. The eclogites occur along the Song Ma Suture zone in northern Vietnam, which is widely regarded as the boundary between the South China and Indochina cratons. The major lithology of the area is pelitic schist that contains garnet and phengite with or without biotite, chloritoid, staurolite and kyanite, and which encloses blocks and lenses of eclogite and amphibolite. The eclogites commonly consist of garnet, omphacite, phengite, rutile, quartz and/or epidote with secondary barroisite. Omphacite is commonly surrounded by a symplectite of Na-poor omphacite and Na-rich plagioclase. In highly retrograded domains, diopside + tremolite + plagioclase symplectites replace the primary phases. Estimated peak-pressure metamorphic conditions based on isochemical phase diagrams for the eclogites are 2.1-2.2 GPa and 600-620 degrees C, even though thermobarometric results yield higher pressure and temperature conditions (2.6-2.8 GPa and 620-680 degrees C). The eclogites underwent a clockwise P-T trajectory with a post-peak-pressure increase of temperature to a maximum of > 750 degrees C at 1.7 GPa and a subsequent cooling during decompression to 650 degrees C and 1.3 GPa, which was followed by additional cooling before close-to-isothermal decompression to similar to 530 degrees C at 0.5 GPa. The surrounding pelitic schist (garnet-chloritoid-phengite) records similar metamorphic conditions (580-600 degrees C at 1.9-2.3 GPa) and a monazite chemical age of 243 +/- 4 Ma. A few monazite inclusions within garnet and the cores of some zoned monazite in garnet-phengite schist record an older thermal event (424 +/- 15 Ma). The present results indicate that the Indochina craton was deeply (> 70 km) subducted beneath the South China craton in the Triassic. The Silurian cores of monazite grains may relate to an older non-collisional event in the Indochina craton.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Loop heat pipe is a passive two-phase heat transport device that is gaining importance as a part of spacecraft thermal control systems and also in applications (such as in avionic cooling and submarines). Hard fill of a loop heat pipe occurs when the compensation chamber is full of liquid. A theoretical study is undertaken to investigate the issues underlying the loop beat pipe hard-fill phenomenon. The results of the study suggest that the mass of charge and the presence of a bayonet have significant impact on the loop heat pipe operation. With a largern mass of charge, a loop heat pipe hard fills at a lower heat load. As the heat load increases, there is a steep rise in the loop heat pipe operating temperature. In a loop heat pipe with a saturated compensation chamber, and also in a hard-filled loop heat pipe without a bayonet, the temperature of the compensation chamber and that of the liquid core are nearly equal. When a loop heat pipe with a bayonet hard fills, the compensation chamber and the evaporator core temperatures are different.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study presents a detailed description on crustal metamorphic signatures of garnet-clinopyroxene-quartz-rutile-bearing high P-T granulites, Samgot unit, Imajingang belt, northwestern Korean Peninsula that formed during Permo-Triassic regional metamorphism related to the amalgamation of East Asian continental fragments. Lenses and blocks of high P-T granulites and garnet-bearing leucosomes occur within mafic metamorphic rocks (mainly amphibolites). The mafic blocks comprise relicts of granoblastic garnet and clinopyroxene with medium-grained quartz and rutile. These relict mineral assemblages are confined to local micro-domains and constitute remnants of peak metamorphism. Plagioclase and amphibole form only as retrograde phases in medium ton coarse-grained moats that rim grain boundaries between relict peak mineral assemblages. This microstructure represents the reaction between garnet, clinopyroxene, quartz and rutile in the presence of melt to form amphibole, plagioclase and titanite with minor biotite. The leucosome domains consist of euhedral garnets within the quartz-K feldspar-plagioclase (granitic) matrix, probably representing peritectic garnet growth along with melting. The rare earth element (REE) composition of minerals also support the peritectic garnet growth with a positive Eu/Eu* (positive Eu anomaly), while the relict garnet shows a slight negative anomaly typical for high-grade granulites. The peak-metamorphic conditions calculated from thermodynamic modeling and compositional isopleths indicate a temperature around c. 900 degrees C at a pressure around c. 20 kbar. The present P-T path indicates a clear multi-stage decompression history with initial decompression and cooling followed by a stage of decompression during hydration possibly during Late Triassic exhumation. The results from this study together with the presence of eclogites from the Hongsung area suggest that the Imjingang area and the western Gyeonggi massif likely resided at crustal levels deeper than those of the eastern and southern part of the Gyeonggi massif. (C) 2009 International Association for Gondwana Research. Published by Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Four new 5-aminoisophthalates of cobalt and nickel have been prepared employing hydro/solvothermal methods: [Co2(C8H5NO4)2(C4H4N2)(H2O)2]·3H2O (I), [Ni2(C8H5NO4)2(C4H4N2)(H2O)2]·3H2O (II), [Co2(H2O)(μ3-OH)2(C8H5NO4)] (III), and [Ni2(H2O)(μ3-OH)2(C8H5NO4)] (IV). Compounds I and II are isostructural, having anion-deficient CdCl2 related layers bridged by a pyrazine ligand, giving rise to a bilayer arrangement. Compounds III and IV have one-dimensional M−O(H)−M chains connected by the 5-aminoisophthalate units forming a three-dimensional structure. The coordinated as well as the lattice water molecules of I and II could be removed and inserted by simple heating−cooling cycles under the atmospheric conditions. The removal of the coordinated water molecule is accompanied by changes in the coordination environment around the M2+ (M = Co, Ni) and color of the samples (purple to blue, Co; green to dark yellow, Ni). This change has been examined by a variety of techniques that include in situ single crystal to single crystal transformation studies and in situ IR and UV−vis spectroscopic studies. Magnetic studies indicate antiferromagnetic behavior in I and II, a field-induced magnetism in III, and a canted antiferromagnetic behavior in IV.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Microbiological quality of the treated wastewater is an important parameter for its reuse. The data oil the Fecal Coliform (FC) and Fecal Streptococcus (FS) at different stages of treatment in the Sewage Treatment Plants (STPs) in Delhi watershed is not available, therefore in the present study microbial profiling of STPs was carried out to assess the effluent quality for present and future reuse options. This Study further evaluates the water quality profiles at different stages of treatment for 16 STPs in Delhi city. These STPs are based on conventional Activated Sludge Process (ASP), extended aeration, physical, chemical and biological treatment (BIOFORE), Trickling Filter and Oxidation Pond. The primary effluent quality produced from most of the STPs was suitable for Soil Aquifer Treatment (SAT). Extended Hydraulic Retention Time (HRT) as a result Of low inflow to the STPS Was responsible for high turbidity, COD and BODs removal. Conventional ASP based STPs achieved 1.66 log FC and 1.06 log FS removal. STPs with extended aeration treatment process produced better quality effluent with maximum 4 log order reduction in FC and FS levels. ``Kondli'' and ``Nilothi'' STPs employing ASP, produced better quality secondary effluent as compared to other STPs based oil similar treatment process. Oxidation Pond based STPs showed better FC and FS removals, whereas good physiochemical quality was achieved during the first half of the treatment. Based upon physical, chemical and microbiological removal efficiencies, actual integrated efficiency (IEa) of each STP was determined to evaluate its Suitability for reuse for irrigation purposes. Except Mehrauli'' and ``Oxidation Pond'', effluents from all other STPs require tertiary treatment for further reuse. Possible reuse options, depending Upon the geographical location, proximity of facilities of potential users based oil the beneficial uses, and sub-soil types, etc. for the Delhi city have been investigated, which include artificial groundwater recharge, aquaculture, horticulture and industrial uses Such as floor washing, boiler feed, and cooling towers, etc. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The wear resistance of high chromium iron is well recorded. However, the same is not the case as regards the use of manganese at higher percentages in high chromium irons and its influence on wear behaviour. Hence, this work highlights the slurry wear characteristics of chromium 16–19%) iron following the introduction of manganese at two levels i.e. 5 and 10%. It is known that the wear properties are dictated by the microstructural features. To alter the structure, the cooling rate of casting has been varied by adopting two different types of moulds (i.e. sand and metal) and subsequently subjecting to thermal treatment. The as-cast and heat treated samples are examined for microstructure and then evaluated for hardness and slurry erosion properties. As the manganese content is increased from 5 to 10%, the hardness showed a decrease in value both in the as-cast and heat treated conditions. The slurry erosion loss, expectedly, showed an increase irrespective of the sample condition (i.e. mould type/heat treatment adopted). The findings are corroborated with the microstructural features obtained through optical and scanning electron microscopy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

[1] The equatorial Indian Ocean (EIO) exhibited anomalous conditions characteristic of an Indian Ocean dipole (IOD) during 2006. The eastern EIO had cold sea surface temperature anomalies (SSTA), lower sea level, shallow thermocline and higher chlorophyll than normal. The anomalies in the east, restricted to the south of the equator, were highest off Sumatra. The western pole of the IOD was marked by warm SSTA and deeper thermocline with maxima on either side of the equator. An ocean general circulation model of the Indian Ocean forced by QuikSCAT winds reproduces the IOD of 2006 remarkably well. The switch over to cooling in the east and warming in the west happened during May and July respectively. In the east, airsea heat flux initiated cold SSTA in the model which were sustained later by oceanic processes. In the west, surface heat fluxes and horizontal advection caused warm SSTA and contribution by the latter decreased after August. Citation: Vinayachandran, P. N., J. Kurian, and C. P. Neema (2007), Indian Ocean response to anomalous conditions in 2006, Geophys. Res. Lett., 34, L15602, doi:10.1029/2007GL030194.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The equatorial Indian Ocean (EIO) exhibited anomalous conditions characteristic of an Indian Ocean dipole (IOD) during 2006. The eastern EIO had cold sea surface temperature anomalies (SSTA), lower sea level, shallow thermocline and higher chlorophyll than normal. The anomalies in the east, restricted to the south of the equator, were highest off Sumatra. The western pole of the IOD was marked by warm SSTA and deeper thermocline with maxima on either side of the equator. An ocean general circulation model of the Indian Ocean forced by QuikSCAT winds reproduces the IOD of 2006 remarkably well. The switch over to cooling in the east and warming in the west happened during May and July respectively. In the east, air-sea heat flux initiated cold SSTA in the model which were sustained later by oceanic processes. In the west, surface heat fluxes and horizontal advection caused warm SSTA and contribution by the latter decreased after August.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A two stage Pulse Tube Cryocooler (PTC) is designed and fabricated which reaches a no-load temperature of 2.5K in the second stage and similar to 60 K in the first stage respectively. The system provides a cooling power of similar to 250 mW at 5K in the second stage. Stainless steel meshes (size 200) and lead (Pb) granules are used as the first stage regenerator materials and combination of Pb with Er3Ni / HoCu2 are used as the second stage regenerator materials. The system operates at 1.6 Hz using a 6 kW water cooled helium compressor. Studies conducted by varying the dimensions of Pulse Tubes and regenerators show that the dimensions of the Pulse Tubes are more critical to the performance of the Cryocooler than those of the regenerators. Experimental studies show that the optimum volume ratios of Er3Ni to Pb and HoCu2 to Pb in the second stage regenerator should be 3:2 and 2:3 respectively for the best performance. Further, systems with HoCu2 performed better than those with Er3Ni. The theoretical analysis of the system has been carried out using a simple isothermal model. The experimentally measured cooling powers are in good agreement with the theoretical predictions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We show from conventional magnetization measurements that the charge order (CO) is completely suppressed in 10 nm Pr0.5Ca0.5MnO3 (PCMO 10) nanoparticles. Novel magnetization measurements, designed by a special high field measurement protocol, show that the dominant ground state magnetic phase is ferromagnetic-metallic (FM-M), which is an equilibrium phase, which coexists with the residual charge ordered anti-ferromagnetic phase (CO AFM) (an arrested phase) and exhibits the characteristic features of a `magnetic glassy state' at low temperatures. It is observed that there is a drastic reduction in the field required to induce the AFM to FM transition (similar to 5-6 T) compared to their bulk counterpart(similar to 27 T); this phase transition is of first order in nature, broad, irreversible and the coexisting phases are tunable with the cooling field. Temperature-dependent magneto-transport data indicate the occurrence of a size-induced insulator-metal transition (TM-I) and anomalous resistive hysteresis (R-H) loops, pointing out the presence of a mixture of the FM-M phase and AFM-I phase.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In-flight collection of air, pre-cooling, liquefaction and separation of liquid oxygen (LOX) are key technologies for futuristic launch vehicles, Vortex tube technology is one of the few potential technologies for this application. Extensive studies have been carried out on straight and conical vortex tubes for developing vortex tube technology for high purity LOX separation. Studies show that 12mm. diameter conical vortex tube with L/D of 10 could achieve LOX purity of similar to 96% with separation efficiency of similar to 14% indicating that it is not possible to obtain both high LOX purity and high separation efficiency simultaneously in a single vortex tube. However, it is possible to achieve both high LOX purity and separation efficiency by staging of vortex tubes. LOX purity of 96% and separation efficiency of similar to 73.5% has been achieved for second stage vortex tube supplied with pre-cooled air having 60% oxygen purity. LOX purity has been further increased to 97% by applying controlled heating power over liquid oxygen flowing discharge surface of the vortex tube.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the present work, solidification of a hyper-eutectic ammonium chloride solution in a bottom-cooled cavity (i.e. with stable thermal gradient) is numerically studied. A Rayleigh number based criterion is developed, which determines the conditions favorable for freckles formation. This criterion, when expressed in terms of physical properties and process parameters, yields the condition for plume formation as a function of concentration, liquid fraction, permeability, growth rate of a mushy layer and thermophysical properties. Subsequently, numerical simulations are performed for cases with initial and boundary conditions favoring freckle formation. The effects of parameters, such as cooling rate and initial concentration, on the formation and growth of freckles are investigated. It was found that a high cooling rate produced larger and more defined channels which are retained for a longer durations. Similarly, a lower initial concentration of solute resulted in fewer but more pronounced channels. The number and size of channels are also found to be related to the mushy zone thickness. The trends predicted with regard to the variation of number of channels with time under different process conditions are in accordance with the experimental observations reported in the literature.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A conventional magnesium alloy, AZ91D, and two creep resistant magnesium alloys, developed for powertrain applications, MRI 153M and MRI 230D, are prepared by high pressure die casting. These alloys are tested for their creep behaviour in the continuous manner, as is the Current practice, and in the interrupted manner, which represents the real life Situation more closely. It is observed that the interrupted creep tests give rise to a primary creep appearing at the beginning of each cycle resulting in a higher average strain rate than that encountered in the continuous creep tests. Further, the shorter the cycle time, higher is the average strain rate in the interrupted creep tests. A higher average strain rate will give rise to a higher strain over the same period. This is attributed to the recovery taking place during the cooling and heating between two cycles. The effect of additional precipitation during interrupted creep tests depends on the nature of the precipitates. The additional precipitation of beta phase during the cooling and heating between two cycles increases the steady state strain rate in the AZ91D and MRI 153M alloys. whereas the additional precipitation of C36 phase during the cooling and heating between two cycles decreases the steady state strain rate in the MRI 230D alloy. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents the results of an investigation on the efficacy of hybrid compression process for refrigerant HFC 134a in cooling applications. The conventional mechanical compression is supplemented by thermal compression using a string of adsorption compressors. Activated carbon is the adsorbent for the thermal compression segment. The alternatives of bottoming either mechanical or thermal compression stages are investigated. It is shown that almost 40% energy saving is realizable by carrying out a part of the compression in a thermal compressor compared to the case when the entire compression is carried out in a single-stage mechanical compressor. The hybrid compression is feasible even when low grade heat is available. Some performance indictors are defined and evaluated for various configurations.