132 resultados para Pulse width
Resumo:
Need to analyze particles in a flow? This system takes electrical pulses from acoustical or optical sensors and groups them into bands representing ranges of particle sizes.
Resumo:
Using inhomogeneous dynamical mean-field theory, we show that the normal-metal proximity effect could force any finite number of Mott-insulating "barrier" planes sandwiched between semi-infinite metallic leads to become "fragile" Fermi liquids. They are fully Fermi-liquid-like at T=0, leading to a restoration of lattice periodicity at zero frequency, with a well-defined Fermi surface, and perfect (ballistic) conductivity. However, the Fermi-liquid character can rapidly disappear at finite omega, V, T, disorder, or magnetism, all of which restore the expected quantum tunneling regime, leading to fascinating possibilities for nonlinear response in devices.
Resumo:
The discharge pulse rates at different magnitude levels are often used as criteria for monitoring the partial-discharge aging of insulation systems. Use of suggested corrections for errors in cumulative probability counting leads to better use of available counters.
Resumo:
A versatile and flexible digital pulse programmer for two-pulse, three-pulse, saturation burst and Carr-Purcell sequences is described. Independently variable controls for pulse widths (0.2 mu s to 100 mu s), delay between pulses (0.2 mu s to 100 s) and for number of pulses (1 to 99) for the saturation burst and for the Carr-Purcell sequence, are brought to the front panel. The programmer can be used for one-shot experiments as well as for repetitive experiments.
Resumo:
Investigations have been carried out of some aspects of the fine-scale structure of turbulence in grid flows, in boundary layers in a zero pressure gradient and in a boundary layer in a strong favourable pressure gradient leading to relaminarization. Using a narrow-band filter with suitable mid-band frequencies, the properties of the fine-scale structure (appearing as high frequency pulses in the filtered signal) were analysed using the variable discriminator level technique employed earlier by Rao, Narasimha & Badri Narayanan (1971). It was found that, irrespective of the type of flow, the characteristic pulse frequency (say Np) defined by Rao et al. was about 0·6 times the frequency of the zero crossings. It was also found that, over the small range of Reynolds numbers tested, the ratio of the width of the fine-scale regions to the Kolmogorov scale increased linearly with Reynolds number in grid turbulence as well as in flat-plate boundarylayer flow. Nearly lognormal distributions were exhibited by this ratio as well as by the interval between successive zero crossings. The values of Np and of the zero-crossing rate were found to be nearly constant across the boundary layer, except towards its outer edge and very near the wall. In the zero-pressure-gradient boundary-layer flow, very near the wall the high frequency pulses were found to occur mostly when the longitudinal velocity fluctuation u was positive (i.e. above the mean), whereas in the outer part of the boundary layer the pulses more often occurred when u was negative. During acceleration this correlation between the fine-scale motion and the sign of u was less marked.
Resumo:
The response of a third order non-linear system subjected to a pulse excitation is analysed. A transformation of the displacement variable is effected. The transformation function chosen is the solution of the linear problem subjected to the same pulse. With this transformation the equation of motion is brought into a form in which the method of variation of parameters is applicable for the solution of the problem. The method is applied to a single axis gyrostabilized platform subjected to an exponentially decaying pulse. The analytical results are compared with digital and analog computer solutions.
Resumo:
High frequency, miniature, pulse tube cryocoolers are extensively used in space applications because of their simplicity. Parametric studies of inertance type pulse tube cooler are performed with different length-to-diameter ratios of the pulse tube with the help of the FLUENT (R) package. The local thermal non-equilibrium of the gas and the matrix is taken into account for the modeling of porous zones, in addition to the wall thickness of the components. Dynamic characteristics and the actual mechanism of energy transfer in pulse are examined with the help of the pulse tube wall time constant. The heat interaction between pulse tube wall and the oscillating gas, leading to surface heat pumping, is quantified. The axial heat conduction is found to reduce the performance of the pulse tube refrigerator. The thermal non-equilibrium predicts a higher cold heat exchanger temperature compared to thermal equilibrium. The pressure drop through the porous medium has a strong non-linear effect due to the dominating influence of Forchheimer term over that of the linear Darcy term at high operating frequencies. The phase angle relationships among the pressure, temperature and the mass flow rate in the porous zones are also important in determining the performance of pulse tuberefrigerator.
Resumo:
It has long been argued that better timing precision allowed by satellites like Rossi X-ray Timing Explorer (RXTE) will allow us to measure the orbital eccentricity and the angle of periastron of some of the bright persistent high-mass X-ray binaries (HMXBs) and hence a possible measurement of apsidal motion in these system. Measuring the rate of apsidal motion allows one to estimate the apsidal motion constant of the mass losing companion star and hence allows for the direct testing of the stellar structure models for these giant stars present in the HMXBs. In the present paper, we use the archival RXTE data of two bright persistent sources, namely Cen X-3 and SMC X-1, to measure the very small orbital eccentricity and the angle of periastron. We find that the small variations in the pulse profiles of these sources, rather than the intrinsic time resolution provided by RXTE, limit the accuracy with which we can measure arrival time of the pulses from these sources. This influences the accuracy with which one can measure the orbital parameters, especially the very small eccentricity and the angle of periastron in these sources. The observations of SMC X-1 in the year 2000 were taken during the high-flux state of the source and we could determine the orbital eccentricity and omega using this data set.
Resumo:
A numerical modelling technique for predicting the detailed performance of a double-inlet type two-stage pulse tube refrigerator has been developed. The pressure variations in the compressor, pulse tube, and reservoir were derived, assuming the stroke volume variation of the compressor to be sinusoidal. The relationships of mass flowrates, volume flowrates, and temperature as a function of time and position were developed. The predicted refrigeration powers are calculated by considering the effect of void volumes and the phase shift between pressure and mass flowrate. These results are compared with the experimental results of a specific pulse tube refrigerator configuration and an existing theoretical model. The analysis shows that the theoretical predictions are in good agreement with each other.
Resumo:
We present a new method for establishing correlation between deuterium and its attached carbon in a deuterated liquid crystal. The method is based on transfer of polarization using the DAPT pulse sequence proposed originally for two spin half nuclei, now extended to a spin-1 and a spin-1/2 nuclei. DAPT utilizes the evolution of magnetization of the spin pair under two blocks of phase shifted BLEW-12 pulses on one of the spins separated by a 90 degree pulse on the other spin. The method is easy to implement and does not need to satisfy matching conditions unlike the Hartmann-Hahn cross-polarization. Experimental results presented demonstrate the efficacy of the method.
Resumo:
A two stage Pulse Tube Cryocooler (PTC) is designed and fabricated which reaches a no-load temperature of 2.5K in the second stage and similar to 60 K in the first stage respectively. The system provides a cooling power of similar to 250 mW at 5K in the second stage. Stainless steel meshes (size 200) and lead (Pb) granules are used as the first stage regenerator materials and combination of Pb with Er3Ni / HoCu2 are used as the second stage regenerator materials. The system operates at 1.6 Hz using a 6 kW water cooled helium compressor. Studies conducted by varying the dimensions of Pulse Tubes and regenerators show that the dimensions of the Pulse Tubes are more critical to the performance of the Cryocooler than those of the regenerators. Experimental studies show that the optimum volume ratios of Er3Ni to Pb and HoCu2 to Pb in the second stage regenerator should be 3:2 and 2:3 respectively for the best performance. Further, systems with HoCu2 performed better than those with Er3Ni. The theoretical analysis of the system has been carried out using a simple isothermal model. The experimentally measured cooling powers are in good agreement with the theoretical predictions.
Resumo:
The pulse-echo apparatus, designed and constructed by the author, has been used to reinvestigate the elastic properties of the eighteen optical glasses. The elastic constants are correct to 0·5%. The results are compared with the earlier investigation which utilised the optical method. The possible causes for large discrepancies observed are critically and briefly discussed. A qualitative interpretation of the results has been successfully attempted. The acoustic velocity increases with the decrease in lead and barium oxides and with increase in calcium oxide and boron trioxide components.
Resumo:
An atmospheric radio noise burst represents the radiation received from one complete lightning flash at the frequency to which a receiver is tuned and within the receiver bandwidth. At tropical latitudes, the principal source of interference in the frequency range from 0.1 to 10 MHz is the burst form of atmospheric radio noise. The structure of a burst shows several approximately rectangular pulses of random amplitude, duration and frequency of recurrence. The influence of the noise on data communication can only be examined when the value of the number of pulses crossing a certain amplitude threshold per unit time of the noise burst is known. A pulse rate counter designed for this purpose has been used at Bangalore (12°58′N, 77°35′E) to investigate the pulse characteristics of noise bursts at 3 MHz with a receiver bandwidth of 3.3 kHz/6d B. The results show that the number of pulses lying in the amplitude range between peak and quasi-peak values of the noise bursts and the burst duration corresponding to these pulses follow log normal distributions. The pulse rates deduced therefrom show certain correlation between the number of pulses and the duration of the noise burst. The results are discussed with a view to furnish necessary information for data communication.
Resumo:
Counting-rate meters normally used for finding pulse frequencies are sluggish in their response to any rapid change in the pulse repetition frequency (P.R.F.). An instrument is described which measures each pulse interval and provides immediately afterwards an output voltage proportional to the reciprocal of interval duration. A response to a change in the P.R.F. as rapidly as is physically possible is obtained. The instrument has wide application in low level radiation detection and in several other fields especially for rapidly varying counting-rates.