142 resultados para Binary panels


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electrical resistance of the binary liquid system cyclohexane + acetic anhydride is measured, in the critical region, both in the pure mixture and when the mixture is doped with small amounts (≈ 100 ppm) of H2O/D2O impurities.T c was approached to aboutt=3×10−6 wheret=(T −T c )/T c . The critical exponentb ≈ 0.35 in the fit of the resistance data to the equationdR/dT ∼t −b does not seem to be affected appreciably by the impurities. There is a sign reversal ofdR/dt in the non-critical region. Binary liquid systems seem to violate the universality of the critical resistivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electrical resistance of the critical binary liquid system C6H12+(CH3CO)2O is measured both in the pure form and when the system is doped with small amounts (≈ 100 ppm) of H2O impurities. Near Tc, the resistance varies as dR/dT = A1+A2 (T-Tc)-b with b ≈ 0.35. Neither the critical exponent b nor the amplitude ratio A1/A2 are affected by the impurities. A sign reversal of dR/dT is noticed at high temperatures T much greater-than Tc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electrical resistance is measured in two binary liquid systems CS2 + CH3NO2 and n-C7H16 + CH3OH in the critical region as a function of frequency from 10 Hz to 100 kHz. The critical exponent b ≈ 0.35 in the singularity of dR/dT α (T - Tc)−b near Tc has no appreciable dependence upon the frequency. Thus any contribution from dielectric dispersion to the critical resistivity is not appreciable. The universal behaviour of the dR/dT anomaly does not seem to be followed in binary liquid systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The pressure dependence of critical parameters xc, Tc, and β have been analysed in four systems namely cyclohexane + acetic anhydride, n-heptane + acetic anhydride, methanol + n-heptane, and carbon disulphide + acetonitrile. The separation temperature was found to increase linearly with pressure the value of dTc/dP being 28 mK, 11 mK, 22 mK, and 25 mK respectively. These are in fair agreement with earlier measurements available for two systems. For the methanol + n-heptane system dTc/dP is apparently not consistent with the value predicted from the specific heat and thermal expansion data.Die Druckabhängigkeit der kritischen Parameter xc, Tc und β ist in den vier Systemen Cyclohexan + Essigsäureanhydrid, n-Heptan + Essigsäureanhydrid, Methanol + n-Heptan und Schwefelkohlenstoff + Acetonitril analysiert worden. Es wurde gefunden, daß die kritische Temperatur linear mit dem Druck ansteigt. Die Werte für dTc/dP betragen 28 mK, 11 mK, 22 mK und 25 mK. Sie sind in guter überein-stimmung mit früheren Messungen an zweien dieser Systeme. Für Methanol + n-Heptan stimmt der Wert für dT/dP offensichtlich nicht mit Werten, die mit Hilfe von Daten für die spezifische Wärme und die thermische Ausdehnung vorhergesagt wurden, überein.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Test results of 12 reinforced concrete (RC) wall panels with openings are presented. The panels have been subjected to in-plane vertical loads applied at an eccentricity to represent possible accidental eccentricity that occurs in practice due to constructional imperfections. The 12 specimens consist of two identical groups of six panels each. One group of panels is tested in one-way in-plane action (i.e., supported at top and bottom edges against lateral displacement). The second group of panels is tested in two-way in-plane action (i.e., supported on all the four edges against lateral displacement). Openings in the panels represent typical door and window openings. Cracking loads, ultimate loads, crack patterns, and lateral deflections of the panels are studied. Empirical methods have been developed for the prediction of ultimate load. Also, lateral deflections, cracking loads, and ultimate loads of identical loads tested under one-way and two-way action are compared.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Test results of 24 reinforced concrete wall panels in two-way action (i.e., supported on all the four sides) and subjected to in-plane vertical load are presented. The load is applied at an eccentricity to represent possible accidental eccentricity that occurs in practice due to constructional imperfections. Influences of aspect ratio, thinness ratio, slendemess ratio, vertical steel, and horizontal steel on the ultimate load are studied. Two equations are proposed to predict the ultimate load carried by the panels. The first equation is empirical and is arrived at from trial and error fitting with test data. The second equation is semi-empirical and is developed from a modification of the buckling strength of thin rectangular plates. Both the equations are formulated so as to give a safe prediction of a large portion of ultimate strength test results. Also, ultimate load cracking load and lateral deflections of identical panels in two-way action (all four sides supported) and oneway action (top and bottom sides only supported) are compared.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to describe the atmospheric turbulence which limits the resolution of long-exposure images obtained using ground-based large telescopes, a simplified model of a speckle pattern, reducing the complexity of calculating field-correlations of very high order, is presented. Focal plane correlations are used instead of correlations in the spatial frequency domain. General tripple correlations for a point source and for a binary are calculated and it is shown that they are not a strong function of the binary separation. For binary separations close to the diffraction limit of the telescope, the genuine triple correlation technique ensures a better SNR than the near-axis Knox-Thompson technique. The simplifications allow a complete analysis of the noise properties at all levels of light.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of binary fluid systems in thermally driven vapour absorption and mechanically driven vapour compression refrigeration and heatpump cycles has provided an impetus for obtaining experimental date on caloric properties of such fluid mixtures. However, direct measurements of these properties are somewhat scarce in spite of the calorimetric techniques described in the literature being quite adequate. Most of the design data are derived through calculations using theoretical models and vapour-liquid equilibrium data. This article addresses the choice of working fluids and the current status on the data availability vis-a-vis engineering applications. Particular emphasis is on organic working fluid pairs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A microscopic theory of the statics and the dynamics of solvation of an ion in a binary dipolar liquid is presented. The theory properly includes the different intermolecular correlations that are present in a binary mixture. As a result, the theory can explain several important aspects of both the statics and the dynamics of solvation that are observed in experiments. It provides a microscopic explanation of the preferential solvation of the more polar species by the solute ion. The dynamics of solvation is predicted to be highly non-exponential, in general. The average relaxation time is found to change nonlinearly with the composition of the mixture. These predictions are in qualitative agreement with the experimental results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The surface tensions of binary mixtures of 1-alkanols (Cl-Cd with benzene, toluene, or xylene were measured. The results were correlated with the activity coefficients calculated through the group contribution method such as UNIFAC, with the maximum deviation from the experimental results less that 5%. The coefficients of the correlation are correlated with the chain length.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The constructional details of an 18-bit binary inductive voltage divider (IVD) for a.c. bridge applications is described. Simplified construction with less number of windings, interconnection of winding through SPDT solid state relays instead of DPDT relays, improves reliability of IVD. High accuracy for most precision measurement achieved without D/A converters. The checks for self consistency in voltage division shows that the error is less than 2 counts in 2(18).