112 resultados para transient loads
Resumo:
Energy-based direct methods for transient stability analysis are potentially useful both as offline tools for planning purposes as well as for online security assessment. In this paper, a novel structure-preserving energy function (SPEF) is developed using the philosophy of structure-preserving model for the system and detailed generator model including flux decay, transient saliency, automatic voltage regulator (AVR), exciter and damper winding. A simpler and yet general expression for the SPEF is also derived which can simplify the computation of the energy function. The system equations and the energy function are derived using the centre-of-inertia (COI) formulation and the system loads are modelled as arbitrary functions of the respective bus voltages. Application of the proposed SPEF to transient stability evaluation of power systems is illustrated with numerical examples.
Resumo:
An application of direct methods to dynamic security assessment of power systems using structure-preserving energy functions (SPEF) is presented. The transient energy margin (TEM) is used as an index for checking the stability of the system as well as ranking the contigencies based on their severity. The computation of the TEM requires the evaluation of the critical energy and the energy at fault clearing. Usually this is done by simulating the faulted trajectory, which is time-consuming. In this paper, a new algorithm which eliminates the faulted trajectory estimation is presented to calculate the TEM. The system equations and the SPEF are developed using the centre-of-inertia (COI) formulation and the loads are modelled as arbitrary functions of the respective bus voltages. The critical energy is evaluated using the potential energy boundary surface (PEBS) method. The method is illustrated by considering two realistic power system examples.
Resumo:
The electrochemical properties of the film-covered anode/solution interface in the magnesium/ manganese dioxide dry cell have been evaluated. The most plausible electrical equivalent circuit description of the Mg/solution interface with the passive film intact, has been identified. These results are based on the analysis of ac impedance and voltage transient measurements made on the dry cell under conditions which cause no damage to the protective passive film on the anode. The study demonstrates the complementary character of impedance and transient measurements when widely different frequency ranges are sampled in each type of investigation. The values and temperature dependence of the anode-film resistance, film capacitance, double-layer capacitance and charge-transfer resistance of the film-covered magnesium/solution interface have been determined. The magnitude of these values and its implications in understanding the important performance aspects of the magnesium/manganese dioxide dry cell are discussed. The study may be extended, in principle, to Li, Al and Ca batteries.
Resumo:
The electrochemical properties of the film-covered anode/solution interface in the magnesium/ manganese dioxide dry cell have been evaluated. The most plausible electrical equivalent circuit description of the Mg/solution interface with the passive film intact, has been identified. These results are based on the analysis of ac impedance and voltage transient measurements made on the dry cell under conditions which cause no damage to the protective passive film on the anode. The study demonstrates the complementary character of impedance and transient measurements when widely different frequency ranges are sampled in each type of investigation. The values and temperature dependence of the anode-film resistance, film capacitance, double-layer capacitance and charge-transfer resistance of the film-covered magnesium/solution interface have been determined. The magnitude of these values and its implications in understanding the important performance aspects of the magnesium/manganese dioxide dry cell are discussed. The study may be extended, in principle, to Li, Al and Ca batteries.
Resumo:
The imprint of the changing surface concentration of minority carriers in photocurrent transients is marginalized in “switch off” transients as compared to “switch on” transients. When the surface level is situated close to either one of the band edges, it is shown that in principle it must be possible to obtain the energy of the surface level from “switch off” transients.The time constants for the “switch on” and “switch off” cases behave differently with potential. While in “switch off”, transient plots, the magnitude of the slope decreases monotonically with increasing band bending potentials; for the “switch on” however, though it decreases and is identical to “switch off” initially, beyond a certain increase in potential the magnitude of the slope shows an increase.
Resumo:
The whole-cell voltage clamp technique was used to record potassium currents in mouse fetal hypothalamic neurons developing in culture medium from days 1 to 17. The neurons were derived from fetuses of IOPS/OF1 mice on the 14th day of gestation. The mature neurons (>six days in culture) showed both a transient potassium current and a non-inactivating delayed rectifier potassium current. These were identified pharmacologically by using the potassium channel blockers tetraethyl ammonium chloride and 4-aminopyridine, and on the basis of their kinetics and voltage sensitivities. The delayed rectifier potassium current had a threshold of −20 mV, a slow time-course of activation, and was sustained during the voltage pulse. The 4-aminopyridine-sensitive current was transient, and was activated from a holding potential more negative (−80 mV) than that required for evoking the delayed rectifier potassium current (−40 mV). The delayed rectifier potassium current was detectable from day 1 onwards, while the transient potassium current showed a distinct developmental trend. The time-constant of inactivation became faster with age in culture. The half steady-state inactivation potential showed a shift towards less negative membrane potentials with age, and the relationship was best described by a logarithmic regression equation.The developmental trend of the transient potassium current may relate functionally to the progressive morphological changes, and the appearance of synaptic connections during ontogenesis.
Resumo:
A new analytical model has been suggested for the hysteretic behaviour of beams. The model can be directly used in a response analysis without bothering to locate the precise point where the unloading commences. The model can efficiently simulate several types of realistic softening hysteretic loops. This is demonstrated by computing the response of cantilever beams under sinusoidal and random loadings. Results are presented in the form of graphs for maximum deflection, bending moment and shear
Resumo:
The material presented in this paper summarizes the progress that has been made in the analysis, design, and testing of concrete structures. The material is summarized in the following documents: 1. Part I - Containment Design Criteria and Loading Combinations - J.D. Stevenson (Stevenson and Associates, Cleveland, Ohio, USA) 2. Part II - Reinforced and Prestressed Concrete Behavior - J. Eibl and M. Curbach (Karlsruhe University, Karlsruhe, Germany) 3. Part III - Concrete Containment Analysis, Design and Related Testing - T.E. Johnson and M.A. Daye (Bechtel Power Corporation, Gaithersburg, Maryland USA) 4. Part IV - Impact and Impulse Loading and Response Prediction - J.D. Riera (School of Engineering - UFRGS, Porto Alegre, RS, Brazil) 5. Part V - Metal Containments and Liner Plate Systems - N.J. Krutzik (Siemens AG, Offenbach Am Main, Germany) 6. Part VI - Prestressed Reactor Vessel Design, Testing and Analysis - J. Nemet (Austrian Research Center, Seibersdorf, Austria) and K.T.S. Iyengar (Indian Institute of Science, Bangalore, India).
Resumo:
A new deep level transient spectroscopy technique is suggested which allows the deep level parameters to be obtained from a single temperature scan. Using large ratio t2/t1 of the measurement gate positions t1 and t2 and analyzing the steep high‐temperature side of the peak, it is demonstrated that the deep level activation energy can be determined with high accuracy.
Resumo:
Direct stability analysis ofAC/DC power systems using a structure-preserving energy function (SPEF) is proposed in this paper. The system model considered retains the load buses thereby enabling the representation of nonlinear voltage dependent loads. TheHVDC system is represented with the same degree of detail as is normally done in transient stability simulation. The converter controllers can be represented by simplified or detailed models. Two or multi-terminalDC systems can be considered. The stability analysis is illustrated with a 3-machine system example and encouraging results have been obtained.
Resumo:
In this paper, a wireless control strategy for parallel operation of three-phase four-wire inverters is proposed. A generalized situation is considered where the inverters are of unequal power ratings and the loads are nonlinear and unbalanced in nature. The proposed control algorithm exploits the potential of sinusoidal domain proportional+multiresonant controller ( in the inner voltage regulation loop) to make the system suitable for nonlinear and unbalanced loads with a simple and generalized structure of virtual output-impedance loop. The decentralized operation is achieved by using three-phase P/Q droop characteristics. The overall control algorithm helps to limit the harmonic contents and the degree of unbalance in the output-voltage waveform and to achieve excellent power-sharing accuracy in spite of mismatch in the inverter output impedances. Moreover, a synchronized turn on with consequent change over to the droop mode is applied for the new incoming unit in order to limit the circulating current completely. The simulation and experimental results from-1 kVA and -0.5 kVA paralleled units validate the effectiveness of the scheme.
Resumo:
An important problem regarding pin joints in a thermal environment is addressed. The motivation emerges from structural safety requirements in nuclear and aerospace engineering. A two-dimensional model of a smooth, rigid misfit pin in a large isotropic sheet is considered as an abstraction. The sheet is subjected to a biaxial stress system and far-field unidirectional heat flow. The thermoelastic analysis is complex due to non-linear load-dependent contact and separation conditions at the pin-hole interface and the absence of existence and uniqueness theorems for the class of frictionless thermoelastic contact problems. Identification of relevant parameters and appropriate synthesis of thermal and mechanical variables enables the thermomechanical generalization of pin-joint behaviour. This paper then proceeds to explore the possibility of multiple solutions in such problems, especially interface contact configuration.
Resumo:
We have consider ed the transient motion of art electrically conducting viscous compressible fluid which is in contact with an insulated infinite disk. The initial motion is considered to be due to the uniform rotation of the disk in an otherwise stationary fluid or due to the uniform rigid rotation of the fluid over a stationary disk. Different cases of transient motion due to finite impulse imparted either to the disk or to the distant fluid have been investigated. Effects of the imposed axial magnetic field and the disk temperature on the transient flow are included. The nonlinear partial differential equations governing the motion are solved numerically using an implicit finite-difference scheme along with the Newton's linearisation technique.
Resumo:
A theoretical and experimental study has been carried out on the transient characteristics of a centrifugal pump during starting and stopping periods. Experiments have been conducted on a volute pump with different valve openings to study the dynamic behaviour of the pump during normal start up and stopping, when a small length of discharge pipe line is connected to discharge flange of the pump. Similar experiments have also been conducted when the test pump was part of a hydraulic system to study the system effect on the transient characteristics. Instantaneous rotational speed, flowrate, and delivery and suction pressures of the pump are recorded and it is observed in ail the tested cases that the change of pump behaviour during the transient period is quasi-steady. The dynamic characteristics of the pump have been analysed by a numerical model using the method of characteristics. The model is presented and the results are compared with the experimental data. As the model contains speed acceleration and unsteady discharge terms, the model can be applied for analyses of purely unsteady cases where the pump dynamic characteristics show considerable departure from their steady-state characteristics.