236 resultados para high voltage


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Formative time lags in nitrogen, oxygen, and dry air are measured with and without a magnetic field over a range of gas pressures (0.05 ' p ' 20.2 torr 5 kPa to 2 MPa, electric field strengths (1.8xO14 EEs 60xlO V m l) and magnetic field strengths (85xl0-4 < B ' 16x10-2 Tesla). For experiments below the Paschen minimum, the electrodes are designed to ensure that breakdown occurs over longer gaps and for experiments above the Paschen minimum, a coaxial cylindrical system is employed. The experimental technique consists of applying pulse voltages to the gap at various constant values of E/p and B/p and measuring the time lags from which the formative time lags are separated. In the gases studed, formative time lags decrease on application of a magnetic field at a given pressure for conditions below the Paschen minimum. The voltages at which the formative time lags remain the same without and with magnetic fields are determined, and electron molecule collision frequencies (v/p) are determined using the Effective Reduced Electric Field [EREF] concept. With increasing ratio of E/p in crossed fields, v/p decreases in all the three gases. Measurements above the Paschen minimum yield formative time lags which increase on application of a magnetic field. Formative time lags in nitrogen in ExB fields are calculated assuming an average collision frequency of 8.5x109 sec-1 torr 1. It is concluded that the EREF concept can be applied to explain formative time lags in ExB fields.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Measurements of the ratio of diffusion coefficient to mobility (D/ mu ) of electrons in SF6-N2 and CCl2F2-N2 mixtures over the range 80

Relevância:

60.00% 60.00%

Publicador:

Resumo:

It is a well know that electrons and positive ions are responsible in the case of electric spark. Investigation have been undertaken in the high voltage laboratory to study the effect of injecting ions (both possitive and negative)into the spark gap.Also the effect of paper screens in blocking the ions being invetsigated.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The electric field in certain electrostatic devices can be modeled by a grounded plate electrode affected by a corona discharge generated by a series of parallel wires connected to a DC high-voltage supply. The system of differential equations that describe the behaviour (i.e., charging and motion) of the conductive particle in such an electric field has been numerically solved, using several simplifying assumptions. Thus, it was possible to investigate the effect of various electrical and mechanical factors on the trajectories of conductive particles. This model has been employed to study the behaviour of coalparticles in fly-ash corona separators.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Several new liquids impregnants for capacitors have been suggested as possible alternatives to PCB'S which are being replaced in view of their harmful effects.The application of castor oil, a vegetable product, has been studied in the authors laboratary with the same obejective.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Experimental results are presented of ionisation (a)a nd electron attachment ( v ) coefficients evaluated from the steady-state Townsend curregnrto wth curves for SFsN2 and CC12FrN2 mixtures over the range 60 S E/P 6 240 (where E is the electric field in V cm" and P is the pressure in Torr reduced to 20'C). In both the mixtures the attachment coefficients (vmu) evaluated were found to follow the relationship; where 7 is the attachment coefficient of pure electronegative gas, F is the fraction of the electronegative gas in the mixture and /3 is a constant. The ionisation coefficients (amlx) generally obeyed the relationship where w2a nd aAa re thei onisation coefficients of nitrogen and the attachinggraess pectively. However, in case of CC12FrN2 mixtures, there were maxima in the a,,,v,a,l ues for CCI2F2 concentrations varying between 10% and 30% at all values of E/P investigated. Effective ionisation coefficients (a - p)/P obtained in these binary mixtures show that the critical E/P (corresponding to (a - q)/P = 0) increases with increase in the concentration of the electronegative gas up to 40%. Further increase in the electronegative gas content does not seem to alter the critical E/P.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

It has been shown that it is possible to extend the validity of the Townsend breakdown criterion for evaluating the breakdown voltages in the complete pd range in which Paschen curves are available. Evaluation of the breakdown voltages for air (pd=0.0133 to 1400 kPa · cm), N2(pd=0.0313 to 1400 kPa · cm) and SF6 (pd=0.3000 to 1200 kPa · cm) has been done and in most cases the computed values are accurate to ±3% of the measured values. The computations show that it is also possible to estimate the secondary ionization coefficient ¿ in the pd ranges mentioned above.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The analysis of transient electrical stresses in the insulation of high voltage rotating machines is rendered difficult because of the existence of capacitive and inductive couplings between phases. The Published theories ignore many of the couplings between phases to obtain the solution. A new procedure is proposed here to determine the transient voltage distribution on rotating machine windings. All the significicant capacitive and inductive couplings between different sections in a phase and between different sections in different phases have been considered in this analysis. The experimental results show good correlation with those computed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this paper we report the analysis of dc breakdown tests on mixtures of CC12F2, SF6, C-C4F8, 2-C4F8, N2, C02, CF4, CHF3, and 1,1,1-CH3CF3 gases on the basis of the NKH formula Vmix=k(pd)aNbUC developed by us earlier for the binary mixtures of SF6 with air, N2, N20, and CO2. It is shown that while a and c have the values 0.915 and 0.850 respectively as earlier, k and b depend on the component gases. There is a good agreement between the calculated values on the basis of the formula and measured values reported in the literature.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The ratio of the electron attachment coefficient eta to the gas pressure p (reduced to 0 degrees C) evaluated from the Townsend current growth curves in binary mixtures of electronegative gases (SF6, CCl2F2, CO2) and buffer gases (N2, Ar, air) clearly indicate that the eta /p ratios do not scale as the partial pressure of electronegative gas in the mixture. Extensive calculations carried out using data experimentally obtained have shown that the attachment coefficient of the mixture eta mix can be expressed as eta mix= eta (1-exp- beta F/(100-F)) where eta is the attachment coefficient of the 100% electronegative gas, F is the percentage of the electronegative gas in the mixture and beta is a constant. The results of this analysis explain to a high degree of accuracy the data obtained in various mixtures and are in very good agreement with the data deduced by Itoh and co-workers (1980) using the Boltzmann equation method.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The oxide-based high resistivity semiconducting Paints can be used on high voltage insulators for improved performance. They were found to exhibit nonlinear I-V characteristics which are reported here. The paints exhibited power law relationship and a sharp transition in merhanism of conduction at a critical voltage.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this study, reduction and desorption of oxides of nitrogen (NOx) were conducted using an electrical discharge plasma technique. The study was carried out using a simulated gas mixture to explore the possibility of re-generation of used adsorbents by a nonthermal plasma desorption technique. Three different types of corona electrodes, namely, pipe, helical wire, and straight wire, were used for analyzing their effectiveness in NOx reduction/desorption. The pipe-type corona electrode exhibited a nitric oxide (NO) conversion of 50%, which is 1.5 times that of the straight-wire-type electrode at an energy density of 175J/L. The helical-wire-type corona electrode exhibited a NOx desorption efficiency almost 4 times that of the pipe-type electrode,indicating the possibility that corona-generated species play a crucial role in desorption.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this paper we report the analysis of dc breakdown tests on mixtures of CC12F2, SF6, C-C4F8, 2-C4F8, N2, C02, CF4, CHF3, and 1,1,1-CH3CF3 gases on the basis of the NKH formula Vmix=k(pd)aNbUC developed by us earlier for the binary mixtures of SF6 with air, N2, N20, and CO2. It is shown that while a and c have the values 0.915 and 0.850 respectively as earlier, k and b depend on the component gases. There is a good agreement between the calculated values on the basis of the formula and measured values reported in the literature.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The firing and delay characteristics of a simple coaxial type of triggered vacuum gap (TVG) are described and compared with the planar type. The designs are new and differ from those reported earlier. By analogy with gaseous breakdown the statistical and formative time lags have been determined.