217 resultados para Evaluation of collections


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The low-temperature plastic flow of alpha-zirconium was studied by employing constantrate tensile tests and differential-stress creep experiments. The activation parameters, enthalpy and area, have been obtained as a function of stress for pure, as well as commercial zirconium. The activation area is independent of grain size and purity and falls to about 9b2 at high stresses. The deformation mechanism below about 700° K is found to be controlled by a single thermally activated process, and not a two-stage activation mechanism. Several dislocation mechanisms are examined and it is concluded that overcoming the Peierls energy humps by the formation of kink pairs in a length of dislocation is the rate-controlling mechanism. The total energy needed to nucleate a double kink is about 0.8 eV in pure zirconium and 1 eV in commercial zirconium

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The performance-based liquefaction potential analysis was carried out in the present study to estimate the liquefaction return period for Bangalore, India, through a probabilistic approach. In this approach, the entire range of peak ground acceleration (PGA) and earthquake magnitudes was used in the evaluation of liquefaction return period. The seismic hazard analysis for the study area was done using probabilistic approach to evaluate the peak horizontal acceleration at bed rock level. Based on the results of the multichannel analysis of surface wave, it was found that the study area belonged to site class D. The PGA values for the study area were evaluated for site class D by considering the local site effects. The soil resistance for the study area was characterized using the standard penetration test (SPT) values obtained from 450 boreholes. These SPT data along with the PGA values obtained from the probabilistic seismic hazard analysis were used to evaluate the liquefaction return period for the study area. The contour plot showing the spatial variation of factor of safety against liquefaction and the corrected SPT values required for preventing liquefaction for a return period of 475 years at depths of 3 and 6 m are presented in this paper. The entire process of liquefaction potential evaluation, starting from collection of earthquake data, identifying the seismic sources, evaluation of seismic hazard and the assessment of liquefaction return period were carried out, and the entire analysis was done based on the probabilistic approach.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the context of the IEEE 802.11e standard for WLANs, we provide an analytical model for obtaining the maximum number of VoIP calls that can be supported on HCCA, such that the delay QoS constraint of the accepted calls is met, when TCP downloads are coexistent on EDCA. In this scenario, we derive the TCP download throughput by using an analytical model for the case where only TCP sessions are present in the WLAN. We show that the analytical model for combined voice and TCP transfers provides accurate results in comparison with simulations (using ns-2).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Since a majority of residential and industrial building hot water needs are around 50 degrees C, an integrated solar water heater could provide a bulk source that blends collection and storage into one unit. This paper describes the design, construction and performance test results of one such water-heating device. The test unit has an absorber area of 1.3 m(2) and can hold 1701 of water, of which extractable volume per day is 1001. Its performance was evaluated under various typical operating conditions. Every morning at about 7:00 a.m., 1001 of hot water were drawn from the sump and replaced with cold water from the mains. Although, during most of the days, the peak temperatures of water obtained are between 50 and 60 degrees C, the next morning temperatures were lower at 45-50 degrees C. Daytime collection efficiencies of about 60% and overall efficiencies of about 40% were obtained. Tests were conducted with and without stratification. Night radiation losses were reduced by use of a screen insulation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, we propose a systolic architecture for hidden-surface removal. Systolic architecture is a kind of parallel architecture best known for its easy VLSI implementability. After discussing the design details of the architecture, we present the results of the simulation experiments conducted in order to evaluate the performance of the architecture.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A series of molecular complexes, both co-crystals and salts, of a triazole drug-alprazolam-with carboxylic acids, boric acid, boronic acids, and phenols have been analyzed with respect to heterosynthons present in the crystal structures. In all cases, the triazole ring behaves as an efficient hydrogen bond acceptor with the acidic coformers. The hydrogen bond patterns exhibited with aromatic carboxylic acids were found to depend on the nature and position of the substituents. Being a strong acid, 2,6-dihydroxybenzoic acid forms a salt with alprazolam. With aliphatic dicarboxylic acids alprazolam forms hydrates and the water molecules play a central role in synthon formation and crystal packing. The triazole ring makes two distinct heterosynthons in the molecular complex with boric acid. Boronic acids and phenols form consistent hydrogen bond patterns, and these are seemingly independent of the substitutional effects. Boronic acids form noncentrosymmetric cyclic synthons, while phenols form O-H center dot center dot center dot N hydrogen bonds with the triazole ring. (C) 2010 Wiley-Liss, Inc. and the American Pharmacists Association J Pharm Sci 99:3743-3753, 2010.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Energy-based direct methods for transient stability analysis are potentially useful both as offline tools for planning purposes as well as for online security assessment. In this paper, a novel structure-preserving energy function (SPEF) is developed using the philosophy of structure-preserving model for the system and detailed generator model including flux decay, transient saliency, automatic voltage regulator (AVR), exciter and damper winding. A simpler and yet general expression for the SPEF is also derived which can simplify the computation of the energy function. The system equations and the energy function are derived using the centre-of-inertia (COI) formulation and the system loads are modelled as arbitrary functions of the respective bus voltages. Application of the proposed SPEF to transient stability evaluation of power systems is illustrated with numerical examples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method has been suggested to accurately determine the DBTT of diffusion aluminide bond coats. Micro-tensile testing of free-standing coating samples has been carried out. The DBTT was determined based on the variation of plastic strain-to-fracture with temperature. The positive features of this method over the previously reported techniques are highlighted. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Using path integrals, we derive an exact expression-valid at all times t-for the distribution P(Q,t) of the heat fluctuations Q of a Brownian particle trapped in a stationary harmonic well. We find that P(Q, t) can be expressed in terms of a modified Bessel function of zeroth order that in the limit t > infinity exactly recovers the heat distribution function obtained recently by Imparato et al. Phys. Rev. E 76, 050101(R) (2007)] from the approximate solution to a Fokker-Planck equation. This long-time result is in very good agreement with experimental measurements carried out by the same group on the heat effects produced by single micron-sized polystyrene beads in a stationary optical trap. An earlier exact calculation of the heat distribution function of a trapped particle moving at a constant speed v was carried out by van Zon and Cohen Phys. Rev. E 69, 056121 (2004)]; however, this calculation does not provide an expression for P(Q, t) itself, but only its Fourier transform (which cannot be analytically inverted), nor can it be used to obtain P(Q, t) for the case v=0.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Present in situ chemical treatment technologies for mitigation of petroleum hydrocarbon contamination are in the developmental stage or being tested. To devise efficient strategies for restricting the movement of petroleum hydrocarbon (PHC) molecules in the contaminated soil, it is proposed to utilize the sorption–interaction relationships between the petroleum contaminants and the soil substrate. The basic questions addressed in this paper are as follows (i) What are the prominent chemical constituents of the various petroleum fractions that interact with the soil substrate? (ii) What are the functional groups of a soil that interact with the contaminants? (iii) What are the bonding mechanisms possible between the soil functional groups and the PHC contaminants? (iv) What are the consequent changes brought about the soil physical properties on interaction with PHC's? (v) What are the factors influencing the interactions between PHC molecules and clay particles of the soil substrate? (vi) What is the possibility of improving the soil's attenuation ability for PHC's? The development of answers to the basic questions reveal that petroleum hydrocarbons comprise a mixture of nonpolar alkanes and aromatic and polycyclic hydrocarbons, that have limited solubility in water. The bonding mechanism between the nonpolar PHC's and the clay surface is by way of van der Waals attraction. The adsorption of the nonpolar hydrocarbons by the clay surface occurs only when their (i.e., the hydrocarbon molecules) solubility in water is exceeded and the hydrocarbons exist in the micellar form. Dilute solutions of hydrocarbons in water, i.e., concentrations of hydrocarbons at or below the solubility limit, have no effect on the hydraulic conductivity of clay soils. Permeation with pure hydrocarbons invariably influences the clay hydraulic conductivity. To improve the attenuation ability of soils towards PHC's, it is proposed to coat the soil surface with "ultra" heavy organic polymers. Adsorption of organic polymers by the clay surface may change the surface properties of the soil from highly hydrophilic (having affinity for water molecules) to organophilic (having affinity for organic molecules). The organic polymers attached to the clay surface are expected to attenuate the PHC molecules by van der Waals attraction, by hydrogen bonding, and also by adsorption into interlayer space in the case of soils containing swelling clays.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

X-Ray structural data, as well as semiempirical and ab initio molecular orbital calculations, reveal no systematic and substantial difference between the C–C bond lengths of cis and trans 1,2-diketones. Additional results on various conformations of 1,2-diimines and 1,2-dithiones follow the same pattern. Therefore, lone-pair repulsions cannot be implicated in the observed lengthening of C–C bonds in isatin and several related molecules. Conjugation in these systems occurs peripherally avoiding the participation of the central C–C bond. Negative hyperconjugative interaction between the oxygen lone pairs and the adjacent C–C σ* orbital is suggested to be the principal reason for the relatively long C–C bond in diketones. This effect is found in both the cis and trans conformations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Amongv arioums ethodtsh,e t ransmissliionne o r thei mpedantcueb em ethohda sb eenm ospt opulafro r thee xperimenetavla luatioonf thea cousticiaml pedanocef a terminatioTnh. ee xistinmg ethodisn,c luding theo nesre porteeda rlierb, y thea uthorrse quirleo catioonf thes oundp ressumrei nima nd/orm axima, or elsem akeu se0 f somei terativep rocedureTsh. e presenpt aperd ealsw ith a methodo f analysios f standinwga vews hichd oesn otd epenodn anyo f thesein volvepdr ocedureIts i.s applicabtloe thec aseo f stationarays w ella sm ovingm ediaI.t enableosn to evaluatteh e impedancoef anyp assivbel ackb ox,a s well as the aeroacoustcich aracteristicosf a sourceo f pulsatingg asf low, with the leaste xperimentawl ork andc omputatiotinm ea ndw itht hee xtraa dvantagoef usinga givenim pedanctueb ef or wavelengtahss largea s fourt imesit s lengthA. methodo f externaml easuremenntost, involvinugs eo f anyi mpedance tubef, or evaluatintgh ea eroacouscthica racteristoicf as sourcoef pulsatingga sf lowi s alsod ealtw ith, based on the definition of attenuation or insertion loss of a muffler.