316 resultados para super-fast laser


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper describes a Simultaneous Implicit (SI) approach for transient stability simulations based on an iterative technique using traingularised admittance matrix [1]. The reduced saliency of generator in the subtransient state is taken advantage of to speed up the algorithm. Accordingly, generator differential equations, except rotor swing, contain voltage proportional to fluxes in the main field, dampers and a hypothetical winding representing deep flowing eddy currents, as state variables. The simulation results are validated by comparison with two independent methods viz. Runge-Kutta simulation for a simplified system and a method based on modelling damper windings using conventional induction motor theory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Theoretical optimization studies of the performance of a combustion driven premixed two-phase flow gasdynamic laser are presented. The steady inviscid nonreacting quasi-one-dimensional two-phase flow model including appropriate finite rate vibrational kinetic rates has been used in the analysis. The analysis shows that the effect of the particles on the optimum performance of the two-phase laser is very small. The results are presented in graphical form. Applied Physics Letters is copyrighted by The American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A study of the effect of N2 reservoir temperature on the small-signal gain in a downstream-mixing 16 μm CO2-N2 GDL is presented. It is shown that the small-signal gain decreases with the increase of N2 reservoir temperature. The conditions for reversing this trend are discussed and the results are presented in the form of graphs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The surface tension gradient driven flow that occurs during laser melting has been studied. The vorticity-streamfunction form of the Navier-Stokes equations and the energy equation has been solved by the ‘Alternative Direction Implicit’ method. It has been shown that the inertia forces in the melt strongly influence the flow pattern in the melt. The convection in the melt modifies the isotherms in the melt at high surface tension Reynolds number and high Prandtl number. The buoyancy driven flow has been shown to be negligible compared to the surface tension gradient driven flow in laser melting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Five cyclobutanethiones with different chromophores at the 3-position were examined for triplet state behaviour in benzene using laser excitation into their low lying nπ*1 band systems. A weak transient absorption attributable to the triplet state is observed in all these cases. Results concerning triplet lifetimes, intersystem crossing yields (S1 → T1), self-quenching kinetics and kinetics of energy transfer to all-trans-1,6-diphenyl-1,3,5-hexatriene and oxygen and quenching by di-t-butyl nitroxide (DTBN) are presented. Intersystem crossing yields estimated with reference to p,p′-dimethoxythiobenzophenone are roughly unity in all five cases. Self-quenching rates are found to be less than diffusion limited and this is attributed to steric crowding at the α positions (dimethyl group). The rates of oxygen and DTBN quenching compare well with those reported for several other thiones in the literature. No transients other than the triplet were detected in the above cyclobutane-thiones.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The theory of transient mode locking for an active modulator in an intracavity frequency-doubled laser is presented. The theory is applied to mode-locked and intracavity frequency-doubled Nd:YAG laser and the mode-locked pulse width is plotted as a function of number of round trips inside the cavity. It is found that the pulse compression is faster and the system takes a very short time to approach the steady state in the presence of a second harmonic generating crystal inside the laser cavity. The effect of modulation depth and the second harmonic conversion efficiency on the temporal behavior of the pulse width is discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A period timing device suitable for processing laser Doppler anemometer signals has been described here. The important features of this instrument are: it is inexpensive, simple to operate, and easy to fabricate. When the concentration of scattering particles is low the Doppler signal is in the form of a burst and the Doppler frequency is measured by timing the zero crossings of the signal. But the presence of noise calls for the use of validation criterion, and a 5–8 cycles comparison has been used in this instrument. Validation criterion requires the differential count between the 5 and 8 cycles to be multiplied by predetermined numbers that prescribe the accuracy of measurement. By choosing these numbers to be binary numbers, much simplification in circuit design has been accomplished since this permits the use of shift registers for multiplication. Validation accuracies of 1.6%, 3.2%, 6.3%, and 12.5% are possible with this device. The design presented here is for a 16-bit processor and uses TTL components. By substituting Schottky barrier TTLs the clock frequency can be increased from about 10 to 30 MHz resulting in an extension in the range of the instrument. Review of Scientific Instruments is copyrighted by The American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The rapid data acquisition, natural fluorescence rejection and experimental ease are the advantages of the ultra-fast Raman loss scattering (URLS) which makes it a unique and valuable molecular structure-determining technique. URLS is an analogue of stimulated Raman scattering (SRS) but far more sensitive than SRS. It involves the interaction of two laser sources, viz. a picosecond (ps) pulse and white light, with the sample leading to the generation of loss signal on the higher energy (blue) side with respect to the wavelength of the ps pulse, unlike the gain signal observed on the red side in SRS. These loss signals are at least 1.5 times more intense than the SRS signals. Also, the very prerequisite of the experimental protocol for signal detection to be on the higher energy side by design eliminates the interference from fluorescence, which always appears on the red side. Unlike coherent anti-Stokes Raman scattering, URLS signals are not precluded by non-resonant background under resonance condition and also being a self-phase matched process, it is experimentally easier.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Semicarbazide hydrobromide which is isomorphous with SEM.HCl, was expected to belong to a new family of ferroelectrics. Dielectric, thermal and other studies on these crystals have yielded results which show many peculiarities but not confirmed ferroelectricity in the low temperature phase. As such a Laser Raman spectrosocopic study of oriented singe crystals of SEM.HBr was made at 298°K and at 253°K. The results have been correlated with structural features and compared with SEM.HCl.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 16-µm CO2-N2 downstream-mixing gasdynamic laser, where a cold CO2 stream is mixed with a vibrationally excited N2 stream at the exit of the nozzle, is studied theoretically. The flow field is analyzed using a two-dimensional, unsteady, laminar and viscous flow model including appropriate finite-rate vibrational kinetic equations. The analysis showed that local small-signal gain up to 21.75 m−1 can be obtained for a N2 reservoir temperature of 2000 K and a velocity ratio of 1:1 between the CO2 and N2 mixing streams. Applied Physics Letters is copyrighted by The American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lithium caesium sulphate has been reported to undergo a phase transition from the room temperature orthorhombic phase with space groupP cmn to a final phase with space groupP 22/n. Though a sharp anomaly in its physical properties has been found at 202.0;K, it was found that there was a need for careful investigations in the vicinity of 240 and 210.0;K. Since the changes in the crystal structure involve primarily a rotation of the SO4 tetrahedron about thec-axis and as this may be reflected both in the intensity and polarisation of the internal as well as external phonon modes, the laser Raman spectra of oriented single crystals of LiCsSO4 at different temperatures were investigated. For correlation and definite identification of the spectral features, its infrared absorption spectrum was also studied. An analysis of the intensities and polarizations of the internal modes of the sulphate ions reveals the change in symmetry of the crystal. The integrated intensity and peak height of thev 1 line, plotted against temperature show anomalous peaks in the region of the phase transition. Differential scanning calorimetric study gives the enthalpy change ΔH across the phase transition to be 0.213 kJ/mol.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A period timing device suitable for processing laser Doppler anemometer signals has been described here. The important features of this instrument are: it is inexpensive, simple to operate, and easy to fabricate. When the concentration of scattering particles is low the Doppler signal is in the form of a burst and the Doppler frequency is measured by timing the zero crossings of the signal. But the presence of noise calls for the use of validation criterion, and a 5–8 cycles comparison has been used in this instrument. Validation criterion requires the differential count between the 5 and 8 cycles to be multiplied by predetermined numbers that prescribe the accuracy of measurement. By choosing these numbers to be binary numbers, much simplification in circuit design has been accomplished since this permits the use of shift registers for multiplication. Validation accuracies of 1.6%, 3.2%, 6.3%, and 12.5% are possible with this device. The design presented here is for a 16-bit processor and uses TTL components. By substituting Schottky barrier TTLs the clock frequency can be increased from about 10 to 30 MHz resulting in an extension in the range of the instrument. Review of Scientific Instruments is copyrighted by The American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The analysis of the characteristics of a synchronously mode-locked and internally frequency-doubled dye laser is presented. Dependence of dye laser pulse characteristics on the cavity length mismatch of the pump laser and dye laser is studied. Variation of the minimum pulsewidth with intracavity bandwidth and the harmonic conversion efficiency is presented in the form of graphs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple technique for determining the energy sensitivities for the thermographic recording of laser beams is described. The principle behind this technique is that, if a laser beam with a known spatial distribution such as a Gaussian profile is used for imaging, the radius of the thermal image formed depends uniquely on the intensity of the impinging beam. Thus by measuring the radii of the images produced for different incident beam intensities the minimum intensity necessary (that is, the threshold) for thermographic imaging is found. The diameter of the laser beam can also be found from this measurement. A simple analysis based on the temperature distribution in the laser heated material shows that there is an inverse square root dependence on pulse duration or period of exposure for the energy fluence of the laser beam required, both for the threshold and the subsequent increase in the size of the recording. It has also been shown that except for low intensity, long duration exposure on very low conductivity materials, heat losses are not very significant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Comparative studies on protein structures form an integral part of protein crystallography. Here, a fast method of comparing protein structures is presented. Protein structures are represented as a set of secondary structural elements. The method also provides information regarding preferred packing arrangements and evolutionary dynamics of secondary structural elements. This information is not easily obtained from previous methods. In contrast to those methods, the present one can be used only for proteins with some secondary structure. The method is illustrated with globin folds, cytochromes and dehydrogenases as examples.