38 resultados para treatment drop-out


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper proposes a compact electric discharge plasma source for controlling NOX emission in diesel engine exhaust. An automobile ignition coil was used to generate the high voltage pulse using flyback topology. This design is aimed at retrofitting the existing catalytic converters with pulse assisted cleaning technique. In this paper we bring out a relative comparison of discharge plasma and plasma-adsorbent process at different gas flow rates. Activated alumina was used as adsorbent. The main emphasis is laid on the development of a compact pulse source from a DC supply for the removal of NOX from the filtered diesel engine exhaust.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new throttling system far SI engines is examined. The SMD of the fuel droplets in the induction system is measured to evaluate the performance of the new device with respect to the conventional throttle plate arrangement. The measurements are conducted at steady now conditions. A forward angular scattering technique with a He-Ne laser beam is used for droplet size measurement. The experiments are carried out with different mixture strength, stream velocity and throttle positions. It is observed that A/F ratio has no effect on SMD. However, stream velocity and throttle position have a significant influence on SMD. The new throttling method is found to be more effective in reducing the SMD, particularly at low throttle opening and high stream velocity compared to the conventional throttle plate.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A generic nonlinear mathematical model describing the human immunological dynamics is used to design an effective automatic drug administration scheme. Even though the model describes the effects of various drugs on the dynamic system, this work is confined to the drugs that kill the invading pathogen and heal the affected organ. From a system theoretic point of view, the drug inputs can be interpreted as control inputs, which can be designed based on control theoretic concepts. The controller is designed based on the principle of dynamic inversion and is found to be effective in curing the �nominal model patient� by killing the invading microbes and healing the damaged organ. A major advantage of this technique is that it leads to a closed-form state feedback form of control. It is also proved from a rigorous mathematical analysis that the internal dynamics of the system remains stable when the proposed controller is applied. A robustness study is also carried out for testing the effectiveness of the drug administration scheme for parameter uncertainties. It is observed from simulation studies that the technique has adequate robustness for many �realistic model patients� having off-nominal parameter values as well.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Drop tube provides a low-cost alternative to study the influence of microgravity in materials processing. In the present paper, the current status of the drop tubes and associated experiments on materials processing are reviewed. Emphasis is placed on the advantages and limitations of these studies. It is pointed out that despite size limitation, large opportunities exist to study the fundamental aspects of the influence of gravity in materials processing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the present study, 6061 Al metallic matrix was reinforced by 12.2 wt% df SiC particulates using liquid metallurgy route. The composite material thus obtained was extruded and characterized in the as-solutionized and peak aged conditions in order to delineate the effect of aging associated precipitation of secondary phases on the tensile fracture behavior of the composite samples. The results' of microstructural characterization studies carried out using scanning electron microscope revealed the increased presence of precipitated secondary phases in the metallic matrix and a more pronounced interfacial segregation of alloying elements in case of peak aged samples when compared to the as-solutionized samples. The results of the fractographic studies conducted on the as-solutionized samples revealed that the failure was dominated by the SiC particulates cracking while for the peak aged samples the fracture surface revealed a comparatively more pronounced SiC/6061 Al debonding and reduced SiC particulates cracking. This change in the failure behavior was rationalized in terms of embrittlement of the interfacial region brought about by the aging heat treatment and is correlated, in addition, with the mechanical properties of the composite samples in as-solutionized and peak aged conditions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The discharge plasma-chemical hybrid process for NOinfinity removal from the flue gas emissions is an extremely effective and economical approach in comparison with the conventional selective catalytic reduction system. In this paper we bring out a relative comparison of several discharge plasma reactors from the point of NO removal efficiency. The reactors were either energized by ac or by repetitive pulses. Ferroelectric pellets were used to study the effect of pellet assisted discharges on gas cleaning. Diesel engine exhaust, at different loads; is used to approximately simulate the flue gas composition. Investigations were carried out at room temperature with respect to the variation of reaction products against the discharge power. Main emphasis is laid on the oxidation of NO to NO2, without reducing NOx concentration (i.e., minimum reaction byproducts), with least power consumption. The produced NO2 will be totally converted to N-2 and Na-2 SO4 using Na-2 SO3. The ac packed-bed reactor and pelletless pulsed corona reactor showed better performance, with minimum reaction products for a given power, when the NO concentration was low (similar to 100 ppm). When the engine load exceeds 50% (NO > 300 ppm) there was not much decrease in NO reduction and more or less all the reactors performed equally. The total operating cost of the plasma-chemical hybrid system becomes $4010/ton of NO, which is 1/3-1/5 of the conventional selective catalytic process.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present work is an attempt to study crack initiation in nuclear grade, 9Cr-1Mo ferritic steel using AE as an online NDE tool. Laboratory experiments were conducted on 5 heat treated Compact Tension (CT) specimens made out of nuclear grade 9Cr-1Mo ferritic steel by subjecting them to cyclic tensile load. The CT Specimens were of 12.5 mm thickness. The Acoustic emission test system was setup to acquire the data continuously during the test by mounting AE sensor on one of the surfaces of the specimen. This was done to characterize AE data pertaining to crack initiation and then discriminate the samples in terms of their heat treatment processes based on AE data. The AE signatures at crack initiation could conclusively bring to fore the heat treatment distinction on a sample to sample basis in a qualitative sense.Thus, the results obtained through these investigations establish a step forward in utilizing AE technique as an on-line measurement tool for accurate detection and understanding of crack initiation and its profile in 9Cr-1Mo nuclear grade steel subjected to different processes of heat treatment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Manmade waterbodies have traditionally been used for domestic and irrigation purposes. Unplanned urbanization and ad-hoc approaches have led to these waterbodies receiving untreated sewage. This enriches and eutrophies the waterbody. A physicochemical and biological analysis of sewage-fed Varthur Lake in Bangalore was carried out and its treatment capabilities in terms of BOD removal, nutrient assimilation and self-remediation were assessed. Anaerobic conditions (0 mg/L) prevail at the inlet which improves towards the outlets due to algal aeration. This removed > 50% BOD in the monsoon season but was inhibited by floating macrophytes in all other seasons. Alkalinity, TDS, conductivity and hardness values were higher when compared to earlier studies. This study shows the lake behaves as an anaerobic~aerobic lagoon with a residence time of 4.8 d treating the wastewater to a considerable extent. Further research is required to optimise the system performance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

pplication of pulsed plasma for gas cleaning is gaining prominence in recent years mainly from the energy consideration point of view. Normally, gas treatment is carried out, at or above room temperature, by a conventional dry type corona reactor. However, this treatment is still inadequate in the removal of certain stable gases present in the exhaust/flue gas mixture. The authors report some interesting results of the treatment of such stable gases with pulsed plasma at very low ambient temperature. Also reported in the paper is an improvement in DeNO/DeNOx efficiency using unconventional wet-type reactors, designed and fabricated by the authors, operating at different ambient temperatures. Apart from laboratory tests on simulated gas mixtures, field tests were also carried out on the exhaust gas of a 8 kW diesel engine. Further, an attempt was made to test the feasibility of a helical wire as a corona electrode in place of the conventional straight wire electrode. A comparative analysis of the various tests is presented together with a note on the energy consideration

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Application of pulsed plasma for gas cleaning is gaining prominence in recent years mainly from the energy consideration point of view. Normally, gas treatment is carried out, at or above room temperature, by a conventional dry type corona reactor. However, this treatment is still inadequate in the removal of certain stable gases present in the exhaust/flue gas mixture. The authors report some interesting results of the treatment of such stable gases with pulsed plasma at very low ambient temperature. Also reported in the paper is an improvement in DeNO/DeNOx efficiency using unconventional wet-type reactors, designed and fabricated by the authors, operating at different ambient temperatures. Apart from laboratory tests on simulated gas mixtures, field tests were also carried out on the exhaust gas of a 8 kW diesel engine. Further, an attempt was made to test the feasibility of a helical wire as a corona electrode in place of the conventional straight wire electrode. A comparative analysis of the various tests is presented together with a note on the energy consideration

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The discharge plasma-chemical hybrid process for NO/sub x/ removal from the due gas emissions is an extremely effective and economical approach in comparison with the conventional selective catalytic reduction system. In this paper we bring out a relative comparison of several discharge plasma reactors from the point of NO removal efficiency. The reactors were either energized by AC or by repetitive pulses. Ferroelectric pellets were used to study the effect of pellet assisted discharges on gas cleaning. Diesel engine exhaust, at different loads, is used to approximately simulate the due gas composition. Investigations were carried out at room temperature with respect to the variation of reaction products against the discharge power. Main emphasis is laid on the oxidation of NO to NO/sub 2/, without reducing NOx concentration (i.e., minimum reaction byproducts), with least power consumption. The produced NO/sub 2/ will be totally converted to N/sub 2/ and Na/sub 2/SO/sub 4/ using Na/sub 2/SO/sub 3/. The AC packed bed reactor and pelletless pulsed corona reactor showed better performance, with minimum reaction products for a given power, when the NO concentration was low (/spl sim/100 ppm). At high engine loads (NO>300 ppm) there was not much decrease in NO/sub x/ reduction and more or less all the reactors performed equally. The paper discusses these observations in detail.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A detailed study on the removal of oxides of nitrogen (NOx) from the filtered/unfiltered exhaust of a stationary diesel engine was carried out using non-thermal plasma (pulsed electrical discharge plasma) process and cascaded processes namely plasma- adsorbent and plasma-catalyst processes. The superior performance of discharge plasma with regard to NOx removal, energy consumption and formation of by-products in unfiltered exhaust environment is identified. In the cascaded plasma-adsorbent process, the plasma was cascaded with adsorbents (MS13X/Activated alumina/Activated charcoal). The cascaded process treating unfiltered exhaust exhibits a very high NOx removal compared to the individual processes and further, the cascaded process gives almost the same NOx removal efficiency irrespective of type of adsorbent used. In the cascaded plasma- catalyst process, the plasma was cascaded with activated alumina catalyst at high temperature. The synergy effect and improved performance of the cascaded process are explained. Further, experiments were conducted at room temperature as well as at higher temperatures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A detailed study on the removal of oxides of nitrogen (NOx) from the exhaust of a stationary diesel engine was carried out using non-thermal plasma (dielectric barrier discharge) process. The objective of the study was to explore the effect of different voltage energizations and exhaust composition on the NOx removal process. Three types of voltage energizations, namely AC, DC and Pulse were examined. Due to the ease of generation of high voltage AC/DC electrical discharges from automobile/Vehicular battery supply for possible retrofitting in exhaust cleaning circuit, it was found relevant to investigate individual energisation cases in detail for NOx removal. AC and Pulse energisations exhibit a superior NOx removal efficiency compared to DC energisation. However,Pulse energisation is found to be more energy efficient. Experiments were further carried out with filtered/ unfiltered (raw) exhaust under pulse energisations. The results were discussed with regard to NOx removal, energy consumption and formation of by-products.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper reports improved performance of advantages when compared to its counterpart as it is cost discharge plasma in filtered engine exhaust treatment. Our effective, low capital and operation costs, salable by- paper deals about the removal of NOX emissions from the diesel products, and integration with the existing systems. In this exhaust by electric discharge plasma. For the treatment of diesel paper we describe an alternate reactor geometry referred to exhaust a new type of reactor referred to as cross-flow dielectric as cross-flow DBD reactor, where the exhaust gas flow barrier discharge reactor has been used, where the gas flow is perpendicular to the wire-cylinder reaction chamber. This perpendicular to the corona electrode. Experiments were reactor is used to treat the actual exhaust of a 3.75 kW diesel- conducted at different flow rates ranging from 2 l/min to 10 l/ generator set. The main emphasis is laid on the NOX treatment min. The discharge plasma assisted barrier discharge reactor of diesel engine exhaust. Experiments were carried out at has shown promising results in NOX removal at high flow rates.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We suggest a method of studying coherence in finite-level systems coupled to the environment and use it for the Hamiltonian that has been used to describe the light-harvesting pigment-protein complex. The method works with the adiabatic states and transforms the Hamiltonian to a form in which the terms responsible for decoherence and population relaxation are separated out. Decoherence is then accounted for nonperturbatively and population relaxation using a Markovian master equation. Almost analytical results can be obtained for the seven-level system, and the calculations are very simple for systems with more levels. We apply the treatment to the seven-level system, and the results are in excellent agreement with the exact numerical results of Nalbach et al. Nalbach, Braun, and Thorwart, Phys. Rev. E 84, 041926 (2011)]. Our approach is able to account for decoherence and population relaxation separately. It is found that decoherence causes only damping of oscillations and does not lead to transfer to the reaction center. Population relaxation is necessary for efficient transfer to the reaction center, in agreement with earlier findings. Our results show that the transformation to the adiabatic basis followed by a Redfield type of approach leads to results in good agreement with exact simulation.