19 resultados para rigid contact lens


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A special finite element (FASNEL) is developed for the analysis of a neat or misfit fastener in a two-dimensional metallic/composite (orthotropic) plate subjected to biaxial loading. The misfit fasteners could be of interference or clearance type. These fasteners, which are common in engineering structures, cause stress concentrations and are potential sources of failure. Such cases of stress concentration present considerable numerical problems for analysis with conventional finite elements. In FASNEL the shape functions for displacements are derived from series stress function solutions satisfying the governing difffferential equation of the plate and some of the boundary conditions on the hole boundary. The region of the plate outside FASNEL is filled with CST or quadrilateral elements. When a plate with a fastener is gradually loaded the fastener-plate interface exhibits a state of partial contact/separation above a certain load level. In misfit fastener, the extent of contact/separation changes with applied load, leading to a nonlinear moving boundary problem and this is handled by FASNEL using an inverse formulation. The analysis is developed at present for a filled hole in a finite elastic plate providing two axes of symmetry. Numerical studies are conducted on a smooth rigid fastener in a finite elastic plate subjected to uniaxial loading to demonstrate the capability of FASNEL.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Maximum intensity contrast has been used as a measure of lens defocus. A photodiode array under the control of 8085 microprocessor is used to measure the maximum intensity contrast and to position the lens for best focus. The lens is moved by a stepper motor under processor control at a speed of 350 to 500 steps/s. At this speed, focusing time was found to be between 5 and 8 s. Under coherent illuminating conditions, an accuracy of ± 50 μm has been achieved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The coalescence of nearly rigid liquid droplets in a turbulent flow field is viewed as the drainage of a thin film of liquid under the action of a stochastic force representing the effect of turbulence. The force squeezing the drop pair is modelled as a correlated random function of time. The drops are assumed to coalesce once the film thickness becomes smaller than a critical thickness while they are regarded as separated if their distance of separation is larger than a prescribed distance. A semi-analytical solution is derived to determine the coalescence efficiency. The veracity of the solution procedure is established via a Monte-Carlo solution scheme. The model predicts a reversing trend of the dependence of the coalescence efficiency on the drop radii, the film liquid viscosity and the turbulence energy dissipation per unit mass, as the relative fluctuation increases. However, the dependence on physical parameters is weak (especially at high relative fluctuation) so that for the smallest droplets (which are nearly rigid) the coalescence efficiency may be treated as an empirical constant. The predictions of this model are compared with those of a white-noise force model. The results of this paper and those in Muralidhar and Ramkrishna (1986, Ind. Engng Chem. Fundam. 25, 554-56) suggest that dynamic drop deformation is the key factor that influences the coalescence efficiency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper deals with the pulsatile blood flow in the lung alveolar sheets by idealizing each of them as a channel covered by porous media. As the blood flow in the lung is of low Reynolds number, a creeping flow is assumed in the channel. The analytical and numerical results for the velocity and pressure distribution in the porous medium are presented. The effect of an imposed slip condition is also studied. Comparisons with the corresponding results for the steady-state case are made at the end.