17 resultados para radiocarbon calibration


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents two methods of star camera calibration to determine camera calibrating parameters (like principal point, focal length etc) along with lens distortions (radial and decentering). First method works autonomously utilizing star coordinates in three consecutive image frames thus independent of star identification or biased attitude information. The parameters obtained in autonomous self-calibration technique helps to identify the imaged stars with the cataloged stars. Least Square based second method utilizes inertial star coordinates to determine satellite attitude and star camera parameters with lens radial distortion, both independent of each other. Camera parameters determined by the second method are more accurate than the first method of camera self calibration. Moreover, unlike most of the attitude determination algorithms where attitude of the satellite depend on the camera calibrating parameters, the second method has the advantage of computing spacecraft attitude independent of camera calibrating parameters except lens distortions (radial). Finally Kalman filter based sequential estimation scheme is employed to filter out the noise of the LS based estimation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Peristaltic pumps were normally used to pump liquids in several chemical and biological applications. In the present study, a peristaltic pump was used to pressurize the chamber (positive as well negative pressures) using atmospheric air. In the present paper, we discuss the development and performance study of an automatic pressurization system to calibrate low range (millibar) pressure sensors. The system includes a peristaltic pump, calibrated pressure sensor (master sensor), pressure chamber, and the control electronics. An in-house developed peristaltic pump was used to pressurize the chamber. A closed loop control system has been developed to detect and adjust the pressure leaks in the chamber. The complete system has been integrated into a portable product. The system performance has been studied for a step response and steady state errors. The system is portable, free from oil contaminants, and consumes less power compared to existing pressure calibration systems. The veracity of the system was verified by calibrating an unknown diaphragm based pressure sensor and the results obtained were satisfactory. (C) 2015 AIP Publishing LLC.