87 resultados para art de conversion
Resumo:
Isophenoxazine, formed by the condensation of two molecules of o-aminophenol, is reduced by an enzyme system from Tecoma stans leaves to two molecules of catechol. The reaction proceeds well under anaerobic conditions; a 1–2 mole stoichiometry between the substrate disappeared and the product formed was maintained. The enzyme showed maximum activity at pH 5. The substrate at high concentrations caused a diminution in the activity and the optimum concentration of substrate was at 6 × 10−4 Image . The enzyme preparation was able to convert cinnabarinic acid and diphenylene dioxide 2,3-quinone into the corresponding catechol substances. The diphenylene dioxide 2,3-quinone at the same concentration was three times more susceptible to enzymic cleavage than isophenoxazine. Cinnabarinic acid inhibited the enzymic cleavage of isophenoxazine competitively. None of the known electron donors was found to activate the reaction. Inhibition studies suggested that intact sulfhydryl groups are necessary for enzyme activity. Heavy metal ions like Hg++, Ag+, Co++, Fe++, Ni++, and Fe3++ inhibited the reaction. Metal chelating agents did not have any effect on the enzyme.
Rapid conversion of retinal (vitamin A aldehyde) to retinoic acid (vitamin A acid) in the living rat
Resumo:
Although several authors have implicated 3-hydroxyanthranilic acid (3-OHA) as an intermediate in tryptophaniacin pathway in animals (Kaplan, 1961), alternative pathways of metabolism of this compound have not been fully explored. Madhusudanan Nair obtained an enzyme from spinach leaves which could convert 3-OHA to cinnabarinic acid (private communication). Viollier and Süllmann (1950) reported the conversion of 3-OHA to an unidentified red compound by rat liver homogenates. The present investigation describes the identification of this product as cinnabarinic acid (2-amino-3-H-isophenoxazine-3-one-1,9-dicarboxylic acid). Cinnabarinic acid is known to occur in nature along with cinnabarin is olated from the fungus Polystictus sanguineus (Gripenberg et al., 1957; Gripenberg, 1958).
Resumo:
An enzyme system which converts anthranilic acid to catechol was detected in the leaves of Tecoma stans, and its properties studied. The system is present exclusively in the chloroplast fraction of the leaves. The optimum pH of the reaction is 5·2 and maximum activity was obtained with citrate-phosphate buffer. There was good stoichiometry between the amounts of anthranilic acid disappeared and the amounts of catechol and ammonia formed. The enzyme system showed an absolute requirement for oxygen and evidence was obtained for the probable participation of NADPH and FAD in the hydroxylation step. The optimum concentration of anthranilic acid was 10−4 M; at higher concentrations the reaction was inhibited to a considerable extent. Cyanide, pyrophosphate, and EDTA also caused inhibition indicating a requirement for metal ions.
Resumo:
dl-3-Methoxy-11-oxo-17β-carboxy-1,3,5(10),6,8-estrapentaene has been converted to dl-3-methoxy-17β-carboxy-1,3,5(10)-estratriene in fairly good yield.
Resumo:
This is the second part of a two part review on the state-of-the-art in holographic optical elements (HOEs). The aspects of fabrication, evaluation, and applications of HOEs, are discussed in this part. It details the direction of future efforts towards finding work-horse type recording media, developing new methods for the evaluation of HOE, and identifying the areas of application where HOEs are to be considered as indispensable components/tools. Finally a summary of all the suggestions for future work made in the two parts is displayed in Table 2 of this part of the review.
Resumo:
A state-of-the-art review on holographic optical elements (HOE) is presented in two parts. In Part I a conceptual overview and an assessment of the current status on the design of HOE have been included. It is pointed out that HOE development based on the use of squeezed light, speckle, non-linear recording, comparative studies between optics and communication approaches, are some of the promising directions for future research in this vital area of photonics.
Resumo:
We have compared the spectral aerosol optical depth (AOD) and aerosol fine mode fraction (AFMF) derived from Moderate Resolution Imaging Spectroradiometer (MODIS) with those of Aerosol Robotic Network (AERONET) at Kanpur (26.45N, 80.35E), northern India for the pre-monsoon season (March to June, 2001-2005). We found that MODIS systematically overestimates AOD during pre-monsoon season (known to be influenced by dust transport from north-west of India). The errors in AOD were correlated with the MODIS top-of-atmosphere apparent surface reflectance in 2.1 mu m channel (rho*(2.1)). MODIS aerosol algorithm uses p*(2.1) to derive the surface reflectance in visible channels (rho(0.47), rho(0.66)) using an empirical mid IR-visible correlation (rho(0.47) = rho(2.1)/4, rho(0.66) = rho(2.1)/2). The large uncertainty in estimating surface reflectance in visible channels (Delta rho(0.66)+/- 0.04, Delta rho(0.47)+/- 0.02) at higher values of p*(2.1) (p*(2.1) > 0.18) leads to higher aerosol contribution in the total reflected radiance at top-of atmosphere to compensate for the reduced surface reflectance in visible channels and thus leads to overestimation of AOD. This was also reflected in the very low values of AFMF during pre-monsoon whose accuracy depends on the aerosol path radiance in 0.47 and 0.66 mu m channels and aerosol models. The errors in AOD were also high in the scattering angle range 110 degrees-140 degrees, where the effect of dust non-spherity on its optical properties is significant. The direct measurements of spectral surface reflectance are required over the Indo-Gangetic basin in order to validate the mid IR-visible relationship. MODIS aerosol models should also be modified to incorporate the effect of non-spherity of dust aerosols.
Resumo:
Denoising of medical images in wavelet domain has potential application in transmission technologies such as teleradiology. This technique becomes all the more attractive when we consider the progressive transmission in a teleradiology system. The transmitted images are corrupted mainly due to noisy channels. In this paper, we present a new real time image denoising scheme based on limited restoration of bit-planes of wavelet coefficients. The proposed scheme exploits the fundamental property of wavelet transform - its ability to analyze the image at different resolution levels and the edge information associated with each sub-band. The desired bit-rate control is achieved by applying the restoration on a limited number of bit-planes subject to the optimal smoothing. The proposed method adapts itself to the preference of the medical expert; a single parameter can be used to balance the preservation of (expert-dependent) relevant details against the degree of noise reduction. The proposed scheme relies on the fact that noise commonly manifests itself as a fine-grained structure in image and wavelet transform allows the restoration strategy to adapt itself according to directional features of edges. The proposed approach shows promising results when compared with unrestored case, in context of error reduction. It also has capability to adapt to situations where noise level in the image varies and with the changing requirements of medical-experts. The applicability of the proposed approach has implications in restoration of medical images in teleradiology systems. The proposed scheme is computationally efficient.
Resumo:
A novel approach for measurement of small rotation angles using imaging method is proposed and demonstrated. A plane mirror placed on a precision rotating table is used for imaging the newly designed composite coded pattern. The imaged patterns are captured with the help of a CCD camera. The angular rotation of the plane mirror is determined from a pair of the images of the pattern, captured once before and once after affecting the tilt of the mirror. Both simulation and experimental results suggest that the proposed approach not only retains the advantages of the original imaging method but also contributes significantly to the enhancement of its measuring range (+/- 4.13 degrees with accuracy of the order of 1 arcsec).
Resumo:
We propose an effective elastography technique in which an acoustic radiation force is used for remote palpation to generate localized tissue displacements, which are directly correlated to localized variations of tissue stiffness and are measured using a light probe in the same direction of ultrasound propagation. The experimental geometry has provision to input light beam along the ultrasound propagation direction, and hence it can be prealigned to ensure proper interception of the focal region by the light beam. Tissue-mimicking phantoms with homogeneous and isotropic mechanical properties of normal and malignant breast tissue are considered for the study. Each phantom is insonified by a focusing ultrasound transducer (1 MHz). The focal volume of the transducer and the ultrasound radiation force in the region are estimated through solving acoustic wave propagation through medium assuming average acoustic properties. The forward elastography problem is solved for the region of insonification assuming the Lame's parameters and Poisson's ratio, under Dirichlet boundary conditions which gives a distribution of displacement vectors. The direction of displacement, though presented spatial variation, is predominantly towards the ultrasound propagation direction. Using Monte Carlo (MC) simulation we have traced the photons through the phantom and collected the photons arriving at the detector on the boundary of the object in the direction of ultrasound. The intensity correlations are then computed from detected photons. The intensity correlation function computed through MC simulation showed a modulation whose strength is found to be proportional to the amplitude of displacement and inversely related to the storage (elastic) modulus. It is observed that when the storage modulus in the focal region is increased the computed displacement magnitude, as indicated by the depth of modulation in the intensity autocorrelation, decreased and the trend is approximately exponential.
Resumo:
In this paper, we present a wavelet - based approach to solve the non-linear perturbation equation encountered in optical tomography. A particularly suitable data gathering geometry is used to gather a data set consisting of differential changes in intensity owing to the presence of the inhomogeneous regions. With this scheme, the unknown image, the data, as well as the weight matrix are all represented by wavelet expansions, thus yielding the representation of the original non - linear perturbation equation in the wavelet domain. The advantage in use of the non-linear perturbation equation is that there is no need to recompute the derivatives during the entire reconstruction process. Once the derivatives are computed, they are transformed into the wavelet domain. The purpose of going to the wavelet domain, is that, it has an inherent localization and de-noising property. The use of approximation coefficients, without the detail coefficients, is ideally suited for diffuse optical tomographic reconstructions, as the diffusion equation removes most of the high frequency information and the reconstruction appears low-pass filtered. We demonstrate through numerical simulations, that through solving merely the approximation coefficients one can reconstruct an image which has the same information content as the reconstruction from a non-waveletized procedure. In addition we demonstrate a better noise tolerance and much reduced computation time for reconstructions from this approach.
Resumo:
Reconstructions in optical tomography involve obtaining the images of absorption and reduced scattering coefficients. The integrated intensity data has greater sensitivity to absorption coefficient variations than scattering coefficient. However, the sensitivity of intensity data to scattering coefficient is not zero. We considered an object with two inhomogeneities (one in absorption and the other in scattering coefficient). The standard iterative reconstruction techniques produced results, which were plagued by cross talk, i.e., the absorption coefficient reconstruction has a false positive corresponding to the location of scattering inhomogeneity, and vice-versa. We present a method to remove cross talk in the reconstruction, by generating a weight matrix and weighting the update vector during the iteration. The weight matrix is created by the following method: we first perform a simple backprojection of the difference between the experimental and corresponding homogeneous intensity data. The built up image has greater weightage towards absorption inhomogeneity than the scattering inhomogeneity and its appropriate inverse is weighted towards the scattering inhomogeneity. These two weight matrices are used as multiplication factors in the update vectors, normalized backprojected image of difference intensity for absorption inhomogeneity and the inverse of the above for the scattering inhomogeneity, during the image reconstruction procedure. We demonstrate through numerical simulations, that cross-talk is fully eliminated through this modified reconstruction procedure.