123 resultados para Vertical Burning
Resumo:
In this paper, analog solutions are presented for the response of a circular footing resting on an elastic half-space with uniform and parabolic contact pressure distributions and subjected to frequency dependent and frequency independent excitations. In addition, an analog solution to a rigid circular footing subjected to frequency dependent excitation is also presented. The results have been compared with the rigorous solution of Sung and the agreement is found to be good.
Resumo:
THE addition of catalysts normally serves the purpose of imparting a desired burning rate change in a composite propellant. These may either retard or enhance the burning rate. Some often quoted catalysts are oxides, chromites and chromates of metals. A lot of work has been done on rinding the effect of the addition of some of these catalysts on the burning rate; however, none seems to have appeared on the influence of lithium fluoride (LiF). Only qualitative reduction in the burning rate of composite propellants with the addition of LiF was reported by Williams et al.1 Dickinson and Jackson2 reported a slight decrease in the specific impulse of composite propellant with the addition of LiF; however, they made no mention of the effect of its addition on the burning rate. We have studied the effect of the addition of varying amounts of LiF on the burning rate of Ammonium Perchlorate (AP)-Polyester propellant.
Resumo:
The flow of single large liquid bubbles under gravity in closed tubes is studied here for the case when the liquid bubble exhibits micropolar behaviour. The film thickness, velocity profile in the bubble and film, and nonNewtonian effects are studied and compared with those for the correspondingNewtonian fluid. The investigation is restricted to the case where the bubble length is far greater than the tube radius.
Resumo:
Abstract is not available.
Resumo:
The vertical uplift resistance of circular plate anchors, embedded horizontally in a clayey stratum whose cohesion increases linearly with depth, has been obtained under undrained (phi = 0) condition. The axi-symmetric static limit analysis formulation in combination with finite elements proposed recently by the authors has been employed. The variation of the uplift factor (F,) with changes in the embedment ratio (H/B) has been computed for several rates of increases of soil cohesion with depth. It is noted that in all the cases, the magnitude of F-c increases continuously with depth up to a certain value of H-cr/B beyond which the uplift factor becomes essentially constant. The proposed static limit analysis formulation is seen to provide acceptable results even for the two other simple chosen axi-symmetric problems.
Resumo:
The information on altitude distribution of aerosols in the atmosphere is essential in assessing the impact of aerosol warming on thermal structure and stability of the atmosphere.In addition, aerosol altitude distribution is needed to address complex problems such as the radiative interaction of aerosols in the presence of clouds. With this objective,an extensive, multi-institutional and multi-platform field experiment (ICARB-Integrated Campaign for Aerosols, gases and Radiation Budget) was carried out under the Geosphere Biosphere Programme of the Indian Space Research Organization (ISRO-GBP) over continental India and adjoining oceans during March to May 2006. Here, we present airborne LIDAR measurements carried out over the east Coast of the India during the ICARB field campaign. An increase in aerosol extinction (scattering + absorption) was observed from the surface upwards with a maximum around 2 to 4 km. Aerosol extinction at higher atmospheric layers (>2 km) was two to three times larger compared to that of the surface. A large fraction (75-85%) of aerosol column optical depth was contributed by aerosols located above 1 km. The aerosol layer heights (defined in this paper as the height at which the gradient in extinction coefficient changes sign) showed a gradual decrease with an increase in the offshore distance. A large fraction (60-75%) of aerosol was found located above clouds indicating enhanced aerosol absorption above clouds. Our study implies that a detailed statistical evaluation of the temporal frequency and spatial extent of elevated aerosol layers is necessary to assess their significance to the climate. This is feasible using data from space-borne lidars such as CALIPSO,which fly in formation with other satellites like MODIS AQUA and MISR, as part of the A-Train constellation.
Resumo:
The influence of atmospheric aerosols on Earth's radiation budget and hence climate, though well recognized and extensively investigated in recent years, remains largely uncertain mainly because of the large spatio-temporal heterogeneity and the lack of data with adequate resolution. To characterize this diversity, a major multi-platform field campaign ICARB (Integrated Campaign for Aerosols, gases and Radiation Budget) was carried out during the pre-monsoon period of 2006 over the Indian landmass and surrounding oceans, which was the biggest such campaign ever conducted over this region. Based on the extensive and concurrent measurements of the optical and physical properties of atmospheric aerosols during ICARB, the spatial distribution of aerosol radiative forcing was estimated over the entire Bay of Bengal (BoB), northern Indian Ocean and Arabian Sea (AS) as well as large spatial variations within these regions. Besides being considerably lower than the mean values reported earlier for this region, our studies have revealed large differences in the forcing components between the BoB and the AS. While the regionally averaged aerosol-induced atmospheric forcing efficiency was 31 +/- 6 W m(-2) tau(-1) for the BoB, it was only similar to 18 +/- 7 W m(-2) tau(-1) for the AS. Airborne measurements revealed the presence of strong, elevated aerosol layers even over the oceans, leading to vertical structures in the atmospheric forcing, resulting in significant warming in the lower troposphere. These observations suggest serious climate implications and raise issues ranging from the impact of aerosols on vertical thermal structure of the atmospheric and hence cloud formation processes to monsoon circulation.
Resumo:
By using the Y(gl(m|n)) super Yangian symmetry of the SU(m|n) supersymmetric Haldane-Shastry spin chain, we show that the partition function of this model satisfies a duality relation under the exchange of bosonic and fermionic spin degrees of freedom. As a byproduct of this study of the duality relation, we find a novel combinatorial formula for the super Schur polynomials associated with some irreducible representations of the Y(gl(m|n)) Yangian algebra. Finally, we reveal an intimate connection between the global SU(m|n) symmetry of a spin chain and the boson-fermion duality relation. (C) 2007 Elsevier B.V. All rights reserved.
Resumo:
By using the axisymmetric finite elements static limit analysis formulation, proposed recently by the authors, the stability numbers (gamma H/c(o)) for an unsupported vertical circular excavation in clays, whose cohesion increases with depth, have been determined under undrained condition; gamma = unit weight, H., height of the excavation and c(o) = cohesion along ground surface. The results are obtained for various values of H/b and m; where b = the radius of the excavation and m = a non-dimensional parameter which accounts for the rate of the increase of cohesion with depth. The values of the stability numbers increase continuously both with increases in H/b and m. The results obtained in this study compare well with those available in literature.(C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
The unsteady mixed convection flow of an incompressible laminar electrically conducting fluid over an impulsively stretched permeable vertical surface in an unbounded quiescent fluid in the presence of a transverse magnetic field has been investigated. At the same time, the surface temperature is suddenly increased from the surrounding fluid temperature or a constant heat flux is suddenly imposed on the surface. The problem is formulated in such a way that for small time it is governed by Rayleigh type of equation and for large time by Crane type of equation. The non-linear coupled parabolic partial differential equations governing the unsteady mixed convection flow under boundary layer approximations have been solved analytically by using the homotopy analysis method as well as numerically by an implicit finite difference scheme. The local skin friction coefficient and the local Nusselt number are found to decrease rapidly with time in a small time interval and they tend to steady-state values for t* >= 5. They also increase with the buoyancy force and suction, but decrease with injection rate. The local skin friction coefficient increases with the magnetic field, but the local Nusselt number decreases. There is a smooth transition from the unsteady state to the steady state. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
An analysis is performed to study the unsteady combined forced and free convection flow (mixed convection flow) of a viscous incompressible electrically conducting fluid in the vicinity of an axisymmetric stagnation point adjacent to a heated vertical surface. The unsteadiness in the flow and temperature fields is due to the free stream velocity, which varies arbitrarily with time. Both constant wall temperature and constant heat flux conditions are considered in this analysis. By using suitable transformations, the Navier-Stokes and energy equations with four independent variables (x, y, z, t) are reduced to a system of partial differential equations with two independent variables (eta, tau). These transformations also uncouple the momentum and energy equations resulting in a primary axisymmetric flow, in an energy equation dependent on the primary flow and in a buoyancy-induced secondary flow dependent on both primary flow and energy. The resulting system of partial differential equations has been solved numerically by using both implicit finite-difference scheme and differential-difference method. An interesting result is that for a decelerating free stream velocity, flow reversal occurs in the primary flow after certain instant of time and the magnetic field delays or prevents the flow reversal. The surface heat transfer and the surface shear stress in the primary flow increase with the magnetic field, but the surface shear stress in the buoyancy-induced secondary flow decreases. Further the heat transfer increases with the Prandtl number, but the surface shear stress in the secondary flow decreases.
Resumo:
Free convection heat transfer from vertical long cylinders and wires were investigated experimentally. The experiments were designed to check the analytical results and the radius of curvature criteria formulated by the same authors. The results for water, the fluid medium used in the present set of experiments, are in excellent agreement with the theory. The results of Hama, Recesso and Christiaens, Kyte, Madden and Piret, in air are also shown to be in close agreement with proposed correlations.