67 resultados para Tension Leg Platform (Tlp)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present an analysis of the interfacial tension model for the movement of the catalytically driven nanorod. The model considers the convective reaction-diffusion equation for the production and diffusion of oxygen around the bimetallic nanorod. We solve the equation and find the concentration difference, which drives the nanorod. We use our expression to calculate the force on the nanorod and find that the result is within 20% of the results found earlier [ W. Paxton et al., J. Am. Chem. Soc. 128, 14881 (2006) ] by an approximate method. Unlike the earlier results, our results are valid from short to long lengths of the nanorod.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Optimization in energy consumption of the existing synchronization mechanisms can lead to substantial gains in terms of network life in Wireless Sensor Networks (WSNs). In this paper, we analyze ERBS and TPSN, two existing synchronization algorithms for WSNs which use widely different approach, and compare their performance in large scale WSNs each of which consists of different type of platform and has varying node density. We, then, propose a novel algorithm, PROBESYNC, which takes advantage of differences in power required to transmit and receive a message on ERBS and TPSN and leverages the shortcomings of each of these algorithms. This leads to considerable improvement in energy conservation and enhanced life of large scale WSNs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A semitheoretical equation for latent heat of vaporization has been derived and tested. The average error in predicting the value at the normal boiling point in the case of about 90 compounds, which includes polar and nonpolar liquids, is about 1.8%. A relation between latent heat of vaporization and surface tension is also derived and is shown to lead to Watson's empirical relation which gives the change of latent heat of vaporization with temperature. This gives a physico-chemical justification for Watson's empirical relation and provides a rapid method of determining latent heats by measuring surface tension.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper is devoted to a consideration of the following problem: A spherical mass of fluid of density varrho1, viscosity μ1 and external radius R is surrounded by a fluid of density varrho2 and viscosity μ2.The fluids are immiscible and incompressible. The interface is accelerated radially by g1: to study the effect of viscosity and surface tension on the stability of the interface. By analyzing the problem in spherical harmonics the mathematical problem is reduced to one of solution of the characteristic determinant equation. The particular case of a cavity bubble, where the viscosity μ1 of the fluid inside the bubble is negligible in comparison with the viscosity μ2 of the fluid outside the bubble, is considered in some detail. It is shown that viscosity has a stabilizing role on the interface; and when g1 > T(n − 1) (n + 2)/R2(varrho2 − varrho1) the stabilizing role of both viscosity and surface tension is more pronounced than would result when either of them is taken individually.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: A number of proteome studies have been performed recently to identify pheromone-related protein expression and their molecular function using genetically modified rodents' urine. However, no such studies have used Indian commensal rodents; interestingly, in a previous investigation, we confirmed the presence of volatile molecules in commensal rodents urine and these molecules seem to be actively involved in pheromonal communication. Therefore, the present study aims to identify the major urinary protein [MUP] present in commensal rat urine, which will help us to understand the protein's expression pattern and intrinsic properties among the rodents globally. Experimental Design: Initially, the total urinary proteins were separated by 1-D and 2-D electrophoresis and then subsequently analyzed by Matrix Assisted Laser Desorption Ionization-Time of Flight and Mass Spectrometer (MALDI-TOF/MS). Furthermore, they were then fragmented with the aid of a Tandem Mass Spectrometer (TOF/TOF) and the identified sequences aligned and confirmed using similarity with the deduced primary structures of members of the lipocalin superfamily.Results: The SDS-PAGE protein profiles showed distinct proteins with molecular masses of 15, 22.4, 25, 28, 42, 50, 55, 68, and 91 kDa. Of these proteins, the 22.4 kDa protein was considered to be target candidate. When 2D electrophoresis was carried out, about similar to 50 spots were detected with different masses and various pI ranges. The 22.4 kDa protein was found to have a pI of about 4.9. This 22.4 kDa protein spot was digested and subjected to mass spectrometry; it was identified as rat MUP. The fragmented peptides from the rat MUP at 935, 1026, 1192, and 1303 m/z were further fragmented with the aid of MS/MS and generated de novo sequence and this confirmed this protein to be the MUP present in the urine of commensal rats.Conclusion: The present investigation confirms the presence of MUP with a molecular mass of 22.4 kDa in the urine of commensal rats. This protein may be involved in the binding of volatile molecules and opens up a discussion about how volatile and non-volatile molecules in the commensal rats' urine may contribute chemo-communication.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents real-time simulation models of electrical machines on FPGA platform. Implementation of the real-time numerical integration methods with digital logic elements is discussed. Several numerical integrations are presented. A real-time simulation of DC machine is carried out on this FPGA platform and important transient results are presented. These results are compared to simulation results obtained through a commercial off-line simulation software

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Results of photoelastic investigation conducted on annulii containing a radial crack at inner edge and subjected to diametrical tension are reported. The cracks are oriented at 90°, 60° and 45° to the loading direction. The Stress-Intensity Factors (SIFs) were determined by analysing the crack-tip stress fields. Smith and Smith's method [Engng Fracture Mech.4, 357–366 (1972)] and a modified method developed earlier by the authors (to be published) were adopted in the evaluation of SIFs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A parametric study was carried out to determine the Stress Intensity Factor (SIF) in a cracked circular ring by using the photoelastic technique. The stress intensity factors for mode I deformation were determined by subjecting the specimens to the tensile loading from inner boundary and through the holes. The results of Non-Dimensional Stress Intensity Factor (NDSIF) variation with non-dimensional crack length for both methods of loading are compared with each other and with published results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

First, the non-linear response of a gyrostabilized platform to a small constant input torque is analyzed in respect to the effect of the time delay (inherent or deliberately introduced) in the correction torque supplied by the servomotor, which itself may be non-linear to a certain extent. The equation of motion of the platform system is a third order nonlinear non-homogeneous differential equation. An approximate analytical method of solution of this equation is utilized. The value of the delay at which the platform response becomes unstable has been calculated by using this approximate analytical method. The procedure is illustrated by means of a numerical example. Second, the non-linear response of the platform to a random input has been obtained. The effects of several types of non-linearity on reducing the level of the mean square response have been investigated, by applying the technique of equivalent linearization and solving the resulting integral equations by using laguerre or Gaussian integration techniques. The mean square responses to white noise and band limited white noise, for various values of the non-linear parameter and for different types of non-linearity function, have been obtained. For positive values of the non-linear parameter the levels of the non-linear mean square responses to both white noise and band-limited white noise are low as compared to the linear mean square response. For negative values of the non-linear parameter the level of the non-linear mean square response at first increases slowly with increasing values of the non-linear parameter and then suddenly jumps to a high level, at a certain value of the non-linearity parameter.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One of the most important factors that affect the pointing of precision payloads and devices in space platforms is the vibration generated due to static and dynamic unbalanced forces of rotary equipments placed in the neighborhood of payload. Generally, such disturbances are of low amplitude, less than 1 kHz, and are termed as ‘micro-vibrations’. Due to low damping in the space structure, these vibrations have long decay time and they degrade the performance of payload. This paper addresses the design, modeling and analysis of a low frequency space frame platform for passive and active attenuation of micro-vibrations. This flexible platform has been designed to act as a mount for devices like reaction wheels, and consists of four folded continuous beams arranged in three dimensions. Frequency and response analysis have been carried out by varying the number of folds, and thickness of vertical beam. Results show that lower frequencies can be achieved by increasing the number of folds and by decreasing the thickness of the blade. In addition, active vibration control is studied by incorporating piezoelectric actuators and sensors in the dynamic model. It is shown using simulation that a control strategy using optimal control is effective for vibration suppression under a wide variety of loading conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we present an algebraic method to study and design spatial parallel manipulators that demonstrate isotropy in the force and moment distributions. We use the force and moment transformation matrices separately, and derive conditions for their isotropy individually as well as in combination. The isotropy conditions are derived in closed-form in terms of the invariants of the quadratic forms associated with these matrices. The formulation is applied to a class of Stewart platform manipulator, and a multi-parameter family of isotropic manipulators is identified analytically. We show that it is impossible to obtain a spatially isotropic configuration within this family. We also compute the isotropic configurations of an existing manipulator and demonstrate a procedure for designing the manipulator for isotropy at a given configuration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have studied the hydrodynamics of freely suspended membranes, liquid as well as crystalline, with surface tension. We find that nonlinear coupling to thermally excited undulations gives a singular contribution to the kinetic coefficients of these systems at low frequency and wavenumber. Our results differ in some important respects from those of Katz and Lebedev on this problem, and can be tested in mechanical impedance as well as time-correlation studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Back face strain (BFS) measurement is now well-established as an indirect technique to monitor crack length in compact tension (CT) fracture specimens [1,2]. Previous work [2] developed empirical relations between fatigue crack propagation (FCP) parameters. BFS, and number of cycles for CT specimens subjected to constant amplitude fatigue loading. These predictions are experimentally validated in terms of the variations of mean values of BFS and load as a function of crack length. Another issue raised by this study concerns the validity of assigning fixed values for the Paris parameters C and n to describe FCP in realistic materials.