114 resultados para PULSES


Relevância:

10.00% 10.00%

Publicador:

Resumo:

A generalized pulse pair has been suggested in which the longitudinal spin order is retained and the transverse components cancelled by random variation of the interval between pulses, in successive applications of the two-dimensional NMR algorithm. This method leads to pure phases and has been exploited to provide a simpler scheme for two-spin filtering and for pure phase spectroscopy in multiple-quantum-filtered two-dimensional NMR experiments.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new current pulsewidth modulation (PWM) method is presented which uses the principle of creating zero three-phase currents at selected instants of time, through which the load current harmonic content can be controlled along with the magnitude of its fundamental content. This gives rise to reduction of motor torque ripples through the selection of suitable PWM patterns and a fast current control in the inverter by varying the pulsewidths of the PWM pattern. Under this new PWM mode of operation, the autosequentially commutated inverter (ASCI) circuit can be modified easily so that a higher number of pulses can be accomodated within a half-cycle, compared to the normal ASCI circuit. The experimental oscillograms verify the effectiveness of the new PWM method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Need to analyze particles in a flow? This system takes electrical pulses from acoustical or optical sensors and groups them into bands representing ranges of particle sizes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A low cost 12 T pulsed magnet system has been integrated with a closed-cycle helium refrigerator. The copper solenoid is directly immersed in liquid nitrogen for reduced electrical resistance and more efficient heat transfer. This ensures a minimal delay of few minutes between pulses. The sample is mounted on the cold finger of the refrigerator and, along with the surrounding vacuum shroud, is inserted into the bore of the solenoid. When combined with software lock-in signal processing to reduce noise, quick but accurate measurements can be performed at temperatures 4 K-300 K up to 12 T. Quantum Hall effect data in a p-channel SiGe/Si heterostructure has been used to calibrate the instrument against a commercial superconducting magnet. Its versatility as a routine characterization tool is demonstrated bymeasuring parallel conduction in Si/SiGe modulation doped heterostructures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple ramp control firing circuit, suitable for use with fully controlled, line-commutated thyristor bridge circuits, is discussed here. This circuit uses very few components and generates the synchronized firing pulses in a simple way. It operates from a single 15 V Supply and has an inherent pulse inhibit facility. This circuit provides the synchronized firing pulses for both thyristors of the same limb in a bridge. To ensure reliability, wide triggering pulses are used, which are modulated to pass through the pulse transformers1 and demodulated before being fed to the thyristor gates. The use of throe such circuits only for a three-phase bridge is discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report linear and nonlinear optical properties of the biologically important Na doped ZnO nanoparticle dispersions. Interesting morphological changes involving a spherical to flowerlike transition have been observed with Na doping. Optical absorption measurements show an exciton absorption around 368 nm. Photoluminescence measurements reveal exciton recombination emission, along with shallow and deep trap emissions. The increased intensity of shallow trap emission with Na doping is attributed to oxygen deficiency and shape changes associated with doping. Nonlinear optical measurements show a predominantly two-photon induced, excited state absorption, when excited with 532 nm, 5 ns laser pulses, indicating potential optical limiting applications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A circuit capable of producing bipolar square pulses of voltages up to +or-400 V, employing an integrated circuit timer and two mercury wetted relays is described. The frequency of the pulses can be varied from a cycle min-1 to 2 kHz. A variable temperature sample chamber and the temperature control and measurement circuits are also described. The performance of the circuit is evaluated using samples of TGS and NaNO2.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Triglycine selenate (TGSe) is isomorphous with Triglycine sulphate and is ferroelectric below 22°C. It is interesting to study the switching process in TGSe in the ferro-state with a view to comparing the results with TSG. The switching process was studied by applying electrical square pulses to produce fields up to 5 kV/cm on the sample, and measuring the parameters characterizing the transient current flowing in the sample, according to the Merz method. The temperature range in which the process was studied was 15°C to -20°C. The results were analysed by applying the Pulvari-Kuebler theory and the parameters α the activation field and µ the mobility of the domains were evaluated. It is found that µ varies with temperature in TGSe in a manner similar to TGS. µ is lesser for TGSe than for TGS for the same shift of temperature from Tc. The switching behaviour of γ-irradiated TGSe is qualitatively similar to that of unirradiated crystal eventhougth the process gets slowed down as a result of irradiation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple instrument that can provide a sequence of timed pulses for first initiating a transient process and then enabling sampling and recording periodically during the course of the transient event is described. The time delay between the first of these sampling pulses and the start of the transient event is adjustable. This sequence generator has additional features that make it ideal for use in acquiring the waveforms when a storage oscilloscope is used as the recording device. For avoiding the clutter caused by many waveforms being recorded at the same place on an oscilloscope screen such features as displacements of waveforms in the X and Y directions and trace blanking at places where the waveform is not required, have been incorporated. This sequence generator has been employed to acquire a sequence of Raman scattered radiation signals from an adiabatically expanding saturated vapour probed by a flashlamp-pumped dye laser.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Need to analyze particles in a flow? This system takes electrical pulses from acoustical or optical sensors and groups them into bands representing ranges of particle sizes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple ramp control firing circuit, suitable for use with fully controlled, line-commutated thyristor bridge circuits, is discussed here. This circuit uses very few components and generates the synchronized firing pulses in a simple way. It operates from a single 15 V Supply and has an inherent pulse inhibit facility. This circuit provides the synchronized firing pulses for both thyristors of the same limb in a bridge. To ensure reliability, wide triggering pulses are used, which are modulated to pass through the pulse transformers1 and demodulated before being fed to the thyristor gates. The use of throe such circuits only for a three-phase bridge is discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pristine and molybdenum filled double walled carbon nanotubes (DWNTs) suspended in D2O show excellent ultrafast optical switching properties investigated through femtosecond Z-scan and degenerate pump-probe method using 50 fs pulses with central photon energy of 1.57 eV. For pristine-DWNT, the two photon absorption coefficient, beta and nonlinear refraction coefficient, n2 are 4.9×10−8 cm/W, and 9.5×10−11 cm2/W, respectively, which yield one photon figure of merit, W=133 and two photon figure of merit, T=0.4. The degenerate pump-probe measurements show strong photoinduced bleaching with biexponential decay with time constants ~150 and 600 fs. ©2009 American Institute of Physics

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A versatile and flexible digital pulse programmer for two-pulse, three-pulse, saturation burst and Carr-Purcell sequences is described. Independently variable controls for pulse widths (0.2 mu s to 100 mu s), delay between pulses (0.2 mu s to 100 s) and for number of pulses (1 to 99) for the saturation burst and for the Carr-Purcell sequence, are brought to the front panel. The programmer can be used for one-shot experiments as well as for repetitive experiments.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The transmitted signal is assumed to consist of a close succession of rectangular pulses of equal width. A matched filter scheme is employed and a theory is developed for a computer-aided optimization of the envelope of monotone compact signals for maximum rejection of dense clutter of any given distribution in range. Specific results are presented and indeterminate cases are discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Investigations have been carried out of some aspects of the fine-scale structure of turbulence in grid flows, in boundary layers in a zero pressure gradient and in a boundary layer in a strong favourable pressure gradient leading to relaminarization. Using a narrow-band filter with suitable mid-band frequencies, the properties of the fine-scale structure (appearing as high frequency pulses in the filtered signal) were analysed using the variable discriminator level technique employed earlier by Rao, Narasimha & Badri Narayanan (1971). It was found that, irrespective of the type of flow, the characteristic pulse frequency (say Np) defined by Rao et al. was about 0·6 times the frequency of the zero crossings. It was also found that, over the small range of Reynolds numbers tested, the ratio of the width of the fine-scale regions to the Kolmogorov scale increased linearly with Reynolds number in grid turbulence as well as in flat-plate boundarylayer flow. Nearly lognormal distributions were exhibited by this ratio as well as by the interval between successive zero crossings. The values of Np and of the zero-crossing rate were found to be nearly constant across the boundary layer, except towards its outer edge and very near the wall. In the zero-pressure-gradient boundary-layer flow, very near the wall the high frequency pulses were found to occur mostly when the longitudinal velocity fluctuation u was positive (i.e. above the mean), whereas in the outer part of the boundary layer the pulses more often occurred when u was negative. During acceleration this correlation between the fine-scale motion and the sign of u was less marked.