95 resultados para HVDC transmission
Resumo:
The main objective of on-line dynamic security assessment is to take preventive action if required or decide remedial action if a contingency actually occurs. Stability limits are obtained for different contingencies. The mode of instability is one of the outputs of dynamic security analysis. When a power system becomes unstable, it splits initially into two groups of generators, and there is a unique cutset in the transmission network known as critical cutset across which the angles become unbounded. The knowledge of critical cutset is additional information obtained from dynamic security assessment, which can be used for initiating preventive control actions, deciding emergency control actions, and adaptive out-of-step relaying. In this article, an analytical technique for the fast prediction of the critical cutset by system simulation for a short duration is presented. Case studies on the New England ten-generator system are presented. The article also suggests the applications of the identification of critical cutsets.
Resumo:
We consider the problem of transmission of correlated discrete alphabet sources over a Gaussian Multiple Access Channel (GMAC). A distributed bit-to-Gaussian mapping is proposed which yields jointly Gaussian codewords. This can guarantee lossless transmission or lossy transmission with given distortions, if possible. The technique can be extended to the system with side information at the encoders and decoder.
Resumo:
The insulation in a dc cable is subjected to both thermal and electric stress at the same time. While the electric stress is generic to the cable, the temperature rise in the insulation is, by and large, due to the Ohmic losses in the conductor. The consequence of this synergic effect is to reduce the maximum operating voltage and causes a premature failure of the cable. The authors examine this subject in some detail and propose a comprehensive theoretical formulation relating the maximum thermal voltage (MTV) to the physical and geometrical parameters of the insulation. The heat flow patterns and boundary conditions considered by the authors here and those found in earlier literature are provided. The MTV of a dc cable is shown to be a function of the load current apart from the resistance of the insulation. The results obtained using the expressions, developed by the authors, are compared with relevant results published in the literature and found to be in close conformity.
Resumo:
In this paper, new results and insights are derived for the performance of multiple-input, single-output systems with beamforming at the transmitter, when the channel state information is quantized and sent to the transmitter over a noisy feedback channel. It is assumed that there exists a per-antenna power constraint at the transmitter, hence, the equal gain transmission (EGT) beamforming vector is quantized and sent from the receiver to the transmitter. The loss in received signal-to-noise ratio (SNR) relative to perfect beamforming is analytically characterized, and it is shown that at high rates, the overall distortion can be expressed as the sum of the quantization-induced distortion and the channel error-induced distortion, and that the asymptotic performance depends on the error-rate behavior of the noisy feedback channel as the number of codepoints gets large. The optimum density of codepoints (also known as the point density) that minimizes the overall distortion subject to a boundedness constraint is shown to be the same as the point density for a noiseless feedback channel, i.e., the uniform density. The binary symmetric channel with random index assignment is a special case of the analysis, and it is shown that as the number of quantized bits gets large the distortion approaches the same as that obtained with random beamforming. The accuracy of the theoretical expressions obtained are verified through Monte Carlo simulations.
Resumo:
Direct observation of events taking place at the contacting interfaces is important to understand many tribological phenomena. Transmission electron microscope (TEM) has the ability to look through materials at very high magnifications. Most of the TEM observations are done long after the deforming loads and stresses have been relaxed and the material state is further disturbed during the specimen preparation. We have developed a specimen holder in which two electron transparent surfaces can be brought in contact and moved relative to each other in JEOL 2000FX microscope. This holder enables visualization of not only the contacting surfaces at nanoscale but also the subsurface deformation resulting from the contact interaction. Sliding experimentS have been carried out mimicking a single asperity sliding contact. A sharp tungsten probe is moved laterally against a tip mounted on a cantilever. Magnitude of the contact instability, when the contact is broken is found to be dependent on the local geometry of the contact.(C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
Expressions for the phase change Φ suffered by microwaves when transmitted through an artificial dielectric composed of metallic discs arranged in a three-dimensional array have been derived with different approaches as follows (i) molecular theory, (ii) electromagnetic theory and (iii) transmission line theory. The phase change depends on the distance t that the wave traverses inside the dielectric and also the spacing d between centre to centre of any two adjacent discs in the three principal directions. Molecular theory indicates Φ as an increasing function of t, whereas, the other two theories indicate Φ as an oscillatory function of t. The transmission line theory also exhibits Φ to be real or imaginary depending on t. Experimental values of Φ as a function of t have been obtained with the help of a microwave (3·2 cms wavelength) interferometer for two dielectrics having d as 1·91 cms and 2·22 cms respectively.
Resumo:
Here the design and operation of a novel transmission electron microscope (TEM) triboprobe instrument with real-time vision control for advanced in situ electron microscopy is demonstrated. The NanoLAB triboprobe incorporates a new high stiffness coarse slider design for increased stability and positioning performance. This is linked with an advanced software control system which introduces both new and flexible in situ experimental functional testing modes, plus an automated vision control feedback system. This advancement in instrumentation design unlocks new possibilities of performing a range of new dynamical nanoscale materials tests, including novel friction and fatigue experiments inside the electron microscope.
Resumo:
The performance of a plate clutch in a two-inertia power transmission system is analysed assuming negligible compliance and using a piecewise linear function to represent the clutch torque characteristic. Expressions defining, for all linear segments of the clutch torque characteristic, dimensionless input and output velocities of the clutch and dimensionless slip period are presented. The use of these expressions in preparing design charts to aid analysis and design of the plate clutch is outlined.
Resumo:
This paper presents a new approach to the location of fault in the high voltage power transmission system using Support Vector Machines (SVMs). A knowledge base is developed using transient stability studies for apparent impedance swing trajectory in the R-X plane. SVM technique is applied to identify the fault location in the system. Results are presented on sample 3-power station, a 9-bus system illustrate the implementation of the proposed method.
Resumo:
This paper describes an approach for the analysis and design of 765kV/400kV EHV transmission system which is a typical expansion in Indian power grid system, based on the analysis of steady state and transient over voltages. The approach for transmission system design is iterative in nature. The first step involves exhaustive power flow analysis, based on constraints such as right of way, power to be transmitted, power transfer capabilities of lines, existing interconnecting transformer capabilities etc. Acceptable bus voltage profiles and satisfactory equipment loadings during all foreseeable operating conditions for normal and contingency operation are the guiding criteria. Critical operating strategies are also evolved in this initial design phase. With the steady state over voltages obtained, comprehensive dynamic and transient studies are to be carried out including switching over voltages studies. This paper presents steady state and switching transient studies for alternative two typical configurations of 765kV/400 kV systems and the results are compared. Transient studies are carried out to obtain the peak values of 765 kV transmission systems and are compared with the alternative configurations of existing 400 kV systems.
Resumo:
Power system disturbances are often caused by faults on transmission lines. When faults occur in a power system, the protective relays detect the fault and initiate tripping of appropriate circuit breakers, which isolate the affected part from the rest of the power system. Generally Extra High Voltage (EHV) transmission substations in power systems are connected with multiple transmission lines to neighboring substations. In some cases mal-operation of relays can happen under varying operating conditions, because of inappropriate coordination of relay settings. Due to these actions the power system margins for contingencies are decreasing. Hence, power system protective relaying reliability becomes increasingly important. In this paper an approach is presented using Support Vector Machine (SVM) as an intelligent tool for identifying the faulted line that is emanating from a substation and finding the distance from the substation. Results on 24-bus equivalent EHV system, part of Indian southern grid, are presented for illustration purpose. This approach is particularly important to avoid mal-operation of relays following a disturbance in the neighboring line connected to the same substation and assuring secure operation of the power systems.
Resumo:
In this paper we address the problem of distributed transmission of functions of correlated sources over a fast fading multiple access channel (MAC). This is a basic building block in a hierarchical sensor network used in estimating a random field where the cluster head is interested only in estimating a function of the observations. The observations are transmitted to the cluster head through a fast fading MAC. We provide sufficient conditions for lossy transmission when the encoders and decoders are provided with partial information about the channel state. Furthermore signal side information maybe available at the encoders and the decoder. Various previous studies are shown as special cases. Efficient joint-source channel coding schemes are discussed for transmission of discrete and continuous alphabet sources to recover function values.
Resumo:
A novel method to account for the transmission line resistances in structure preserving energy functions (SPEF) is presented in this paper. The method exploits the equivalence of a lossy network having the same conductance to susceptance ratio for all its elements to a lossless network with a new set of power injections. The system equations and the energy function are developed using centre of inertia (COI) variables and the loads are modelled as arbitrary functions of respective bus voltages. The application of SPEF to direct transient stability evaluation is presented considering a realistic power system example.
Resumo:
A common and practical paradigm in cooperative communications is the use of a dynamically selected 'best' relay to decode and forward information from a source to a destination. Such a system consists of two core phases: a relay selection phase, in which the system expends resources to select the best relay, and a data transmission phase, in which it uses the selected relay to forward data to the destination. In this paper, we study and optimize the trade-off between the selection and data transmission phase durations. We derive closed-form expressions for the overall throughput of a non-adaptive system that includes the selection phase overhead, and then optimize the selection and data transmission phase durations. Corresponding results are also derived for an adaptive system in which the relays can vary their transmission rates. Our results show that the optimal selection phase overhead can be significant even for fast selection algorithms. Furthermore, the optimal selection phase duration depends on the number of relays and whether adaptation is used.