26 resultados para Bartington MS2E1 surface sanning sensor
Resumo:
A low cost, reagent free, Escherichia coli sensor is demonstrated with graphene, on transparent flexible acetate substrate. Graphene is grown on 100 mu m thick Cu foil, using CVD process and subsequently transferred on to a flexible acetate substrate. Gold electrodes are deposited on graphene to form a two terminal, interdigitated capacitor structure. Impedance spectroscopy (10 Hz to 100 kHz) is performed to characterize the change in impedance, as a function of E. coli concentration on graphene surface. The residual methyl groups on graphene, resulting from the transfer process, act as binding sites for E. coli. It has been observed that the resistance of graphene decreases with increasing E. coli concentration. This is due to the increased hole doping induced by negatively charged E. coli. A sensitivity of 60% is achieved for an E. coli concentration of 4.5 x 10(7) cfu/ml. An equivalent RC model is proposed to explain the sensing mechanism. (C) 2013 Elsevier B.V. All rights reserved.
Resumo:
[1] Evaporative fraction (EF) is a measure of the amount of available energy at the earth surface that is partitioned into latent heat flux. The currently operational thermal sensors like the Moderate Resolution Imaging Spectroradiometer (MODIS) on satellite platforms provide data only at 1000 m, which constraints the spatial resolution of EF estimates. A simple model (disaggregation of evaporative fraction (DEFrac)) based on the observed relationship between EF and the normalized difference vegetation index is proposed to spatially disaggregate EF. The DEFrac model was tested with EF estimated from the triangle method using 113 clear sky data sets from the MODIS sensor aboard Terra and Aqua satellites. Validation was done using the data at four micrometeorological tower sites across varied agro-climatic zones possessing different land cover conditions in India using Bowen ratio energy balance method. The root-mean-square error (RMSE) of EF estimated at 1000 m resolution using the triangle method was 0.09 for all the four sites put together. The RMSE of DEFrac disaggregated EF was 0.09 for 250 m resolution. Two models of input disaggregation were also tried with thermal data sharpened using two thermal sharpening models DisTrad and TsHARP. The RMSE of disaggregated EF was 0.14 for both the input disaggregation models for 250 m resolution. Moreover, spatial analysis of disaggregation was performed using Landsat-7 (Enhanced Thematic Mapper) ETM+ data over four grids in India for contrasted seasons. It was observed that the DEFrac model performed better than the input disaggregation models under cropped conditions while they were marginally similar under non-cropped conditions.
Resumo:
This paper presents the design technique that has been adopted for packaging of Polyvinylidene fluoride (PVDF) nasal sensor for biomedical applications. The PVDF film with the dimension of length 10mm, width 5mm and thickness 28 mu m was firmly adhered on one end of plastic base (8mmx5mmx30 mu m) in such a way that it forms a cantilever configuration leaving the other end free for deflection. Now with the leads attached on the surface of the PVDF film, the cantilever configuration becomes the PVDF nasal sensor. For mounting a PVDF nasal sensor, a special headphone was designed, that can fit most of the human head sizes. Two flexible strings are soldered on either side of the headphone. Two identical PVDF nasal sensors were then connected to either side of flexible string of the headphone in such a way that they are placed below the right and left nostrils respectively without disturbing the normal breathing. When a subject wares headphone along with PVDF nasal sensors, two voltage signals due to the piezoelectric property of the PVDF film were generated corresponding to his/her nasal airflow from right and left nostril. The entire design was made compact, so that PVDF nasal sensors along with headphone can be made portable. No special equipment or machines are needed for mounting the PVDF nasal sensors. The time required for packaging of PVDF nasal sensors was less and the approximate cost of the entire assembly (PVDF nasal sensors + headphone) was very nominal.
Resumo:
Transparent conducting ZnO films were prepared at substrate temperature 400 degrees C with different film thicknesses by nebulizer spray pyrolysis method on glass substrates. XRD studies reveal that the films are polycrystalline in nature having hexagonal crystal structure with preferred grain orientations along (0 0 2) and (1 0 1) directions. The crystallite size increases along (0 0 2) plane with the thickness increase and attains a maximum 109 nm for 913 nm film thickness. Analysis of structural parameters indicates that the films having thickness 913 nm are found to have minimum dislocation density and strain values. The HRSEM measurements show that the surface morphology of the films also changes with film thickness. EDAX estimates the average atomic percentage ratio of Zn and O in the ZnO films. Optical studies reveal the band gap energy decrease from 3.27 to 3.14 eV with increase of film thickness. Room temperature PL spectra show the near-band-edge emission and deep-level emission due to the presence of defects in the ZnO thin films. Impedance spectroscopy analysis indicates that grain boundary resistance decreases with the increasing ammonia concentration up to 500 ppm and the maximum sensitivity is found to be 1.7 for 500 ppm of ammonia. (C) 2014 Elsevier Ltd. All rights reserved.
Resumo:
Volatile organic compounds (VOCs) are present in our every day used products such as plastics, cosmetics, air fresheners, paint, etc. The determination of amount of VOC present in atmosphere can be carried out via various sensors. In this work a nanocomposite of a novel thiophene based conducting polymer and carbon black is used as a volatile organic compound sensor. The fabricated 2 lead chemiresistor sensor was tested for vapours of toluene, acetone, cylcohexane, and carbon tetrachloride. The sensor responds to all the vapours, however, exhibit maximum response to toluene vapours. The sensor was evaluated for various concentrations of toluene. The lower limit of detection of the sensor is 15 +/- 10 ppm. The study of the effect of humidity on senor response to toluene showed that the response decreases at higher humidity conditions. The surface morphology of the nanocomposite was characterized by scanning electron microscopy. Diffuse reflectance spectroscopy was used to investigate the absorption of vapours by the nanocomposite film. Contact angle measurements were used to present the effect of water vapour on the toluene response of nanocomposite film. Solubility parameter of the conducting polymer is predicted by molecular dynamics. The sensing behaviour of the conducting polymer is correlated with solubility parameter of the polymer. Dispersion interaction of conducting polymer with toluene is believed to be the reason for the selective response towards toluene. (C) 2014 Elsevier B.V. All rights reserved.
Resumo:
Graphene has emerged as one of the strongest candidates for post-silicon technologies. One of the most important applications of graphene in the foreseeable future is sensing of particles of gas molecules, biomolecules or different chemicals or sensing of radiation of particles like alpha, gamma or cosmic particles. Several unique properties of graphene such as its extremely small thickness, very low mass, large surface to volume ratio, very high absorption coefficient, high mobility of charge carriers, high mechanical strength and high Young's modulus make it exceptionally suitable for making sensors. In this article we review the state-of-the-art in the application of graphene as a material and radiation detector, focusing on the current experimental status, challenges and the excitement ahead.
Resumo:
The sensing of relative humidity (RH) at room temperature has potential applications in several areas ranging from biomedical to horticulture, paper, and textile industries. In this paper, a highly sensitive humidity sensor based on carbon nanotubes (CNTs) coated on the surface of an etched fiber Bragg grating (EFBG) sensor has been demonstrated, for detecting RH over a wide range of 20%-90% at room temperature. When water molecules interact with the CNT coated EFBG, the effective refractive index of the fiber core changes, resulting in a shift in the Bragg wavelength. It has been possible to achieve a high sensitivity of similar to 31 pm/% RH, which is the highest compared with many of the existing FBG-based humidity sensors. The limit of detection in the CNT coated EFBG has been found to be similar to 0.03 RH. The experimental data shows a linear response of Bragg wavelength shift with increase in humidity. This novel method of incorporating CNTs on to the FBG sensor for humidity sensing has not been reported before.
Resumo:
Land surface temperature (LST) is an important variable in climate, hydrologic, ecological, biophysical and biochemical studies (Mildrexler et al., 2011). The most effective way to obtain LST measurements is through satellites. Presently, LST from moderate resolution imaging spectroradiometer (MODIS) sensor is applied in various fields due to its high spatial and temporal availability over the globe, but quite difficult to provide observations in cloudy conditions. This study evolves of prediction of LST under clear and cloudy conditions using microwave vegetation indices (MVIs), elevation, latitude, longitude and Julian day as inputs employing an artificial neural network (ANN) model. MVIs can be obtained even under cloudy condition, since microwave radiation has an ability to penetrate through clouds. In this study LST and MVIs data of the year 2010 for the Cauvery basin on a daily basis were obtained from MODIS and advanced microwave scanning radiometer (AMSR-E) sensors of aqua satellite respectively. Separate ANN models were trained and tested for the grid cells for which both LST and MVI were available. The performance of the models was evaluated based on standard evaluation measures. The best performing model was used to predict LST where MVIs were available. Results revealed that predictions of LST using ANN are in good agreement with the observed values. The ANN approach presented in this study promises to be useful for predicting LST using satellite observations even in cloudy conditions. (C) 2015 The Authors. Published by Elsevier B.V.
Resumo:
Recently, graphene has attracted much attention due to its unique electrical and thermal properties along with its high surface area, and hence presents an ideal sensing material. We report a novel configuration of a graphene based flame sensor by exploiting the response of few layer graphene to a flame along two different directions, where flame detection results from a difference in heat transfer mechanisms. A complete sensor module was developed with a signal conditioning circuit that compensates for any drift in the baseline of the sensor, along with a flame detection algorithm implemented in a microcontroller to detect the flame. A pre-defined threshold for either of the sensors is tunable, which can be varied based on the nature of the flame, hence presenting a system that can be used for detection of any kind of flame. This finding also presents a scalable method that opens avenues to modify complicated sensing schemes.
Resumo:
Non-invasive, real-time dynamic monitoring of pressure inside a column with the aid of Fiber Bragg Grating (FBG) sensor is presented in the present work. A bare FBG sensor is adhered on the circumference of a pressure column normal to its axis, which has the ability to acquire the hoop strain induced by the pressure variation inside the column. Pressure induced hoop strain response obtained using FBG sensor is validated against the pressure measurements obtained from conventional pressure gauge. Further, a protrusion setup on the outer surface of the column has been proposed over which a secondary FBG sensor is bonded normal to its axis, in order to increase the gauge length of this FBG sensor. This is carried out in order to validate the variation in sensitivity of the protrusion bonded FBG sensor compared to the bare FBG sensor bonded over the surface. A comparative study is done between the two FBG sensors and a conventional pressure gauge in order to establish the capacity of FBG sensor obtained hoop strain response for pressure monitoring inside the column.
Resumo:
In this article, the design and development of a Fiber Bragg Grating (FBG) based displacement sensor package for submicron level displacement measurements are presented. A linear shift of 12.12 nm in Bragg wavelength of the FBG sensor is obtained for a displacement of 6 mm with a calibration factor of 0.495 mu m/pm. Field trials have also been conducted by comparing the FBG displacement sensor package against a conventional dial gauge, on a five block masonry prism specimen loaded using three-point bending technique. The responses from both the sensors are in good agreement, up to the failure of the masonry prism. Furthermore, from the real-time displacement data recorded using FBG, it is possible to detect the time at which early creaks generated inside the body of the specimen which then prorogate to the surface to develop visible surface cracks; the respective load from the load cell can be obtained from the inflection (stress release point) in the displacement curve. Thus the developed FBG displacement sensor package can be used to detect failures in structures much earlier and to provide an adequate time to exercise necessary action, thereby avoiding the possible disaster.