275 resultados para Reactive power (Electrical engineering)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple multiple pulsewidth modulated (MPWM) ac chopper using power transistors for 3-ý power control is discussed. 120ý chopping period is used for main transistors so that the circuit can accommodate resistive and lagging or leading power factor loads. Only 1-ý sensing is used for 3-ý control. An alternate economical power and control schemes for 3-ý MPWM ac choppers suitable only for resistive loads is also suggested. The experimental results for 12 choppings per cycle are given.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a novel approach for designing of generator excitation controllers using Interconnection and Damping Assignment Passivity Based Control (IDA-PBC) technique for a Single Machine Infinite Bus (SMIB) system that can also be directly used in a multi-machine environment. The generator system equations are modified by referencing the rotor angle with respect to the secondary of the transformer bus instead of the infinite bus. For the modified system equations, IDA-PBC is applied to stabilize the system around an operating condition. The IDA-PBC design results in a Lyapunov function for the modified system. The new control law is practically feasible and can be applied directly to multi-machine system without referring to external system parameters. The effectiveness of the proposed controller is tested on a SMIB and a 10 generator 39 bus test system for a range of operating conditions. The Proposed excitation controller has shown good performance for both small and large disturbances when compared to the performance of a conventional static exciter with power system stabilizer.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mesh topologies are important for large-scale peer-to-peer systems that use low-power transceivers. The Quality of Service (QoS) in such systems is known to decrease as the scale increases. We present a scalable approach for dissemination that exploits all the shortest paths between a pair of nodes and improves the QoS. Despite th presence of multiple shortest paths in a system, we show that these paths cannot be exploited by spreading the messages over the paths in a simple round-robin manner; nodes along one of these paths will always handle more messages than the nodes along the other paths. We characterize the set of shortest paths between a pair of nodes in regular mesh topologies and derive rules, using this characterization, to effectively spread the messages over all the available paths. These rules ensure that all the nodes that are at the same distance from the source handle roughly the same number of messages. By modeling the multihop propagation in the mesh topology as a multistage queuing network, we present simulation results from a variety of scenarios that include link failures and propagation irregularities to reflect real-world characteristics. Our method achieves improved QoS in all these scenarios.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The paper describes a Simultaneous Implicit (SI) approach for transient stability simulations based on an iterative technique using traingularised admittance matrix [1]. The reduced saliency of generator in the subtransient state is taken advantage of to speed up the algorithm. Accordingly, generator differential equations, except rotor swing, contain voltage proportional to fluxes in the main field, dampers and a hypothetical winding representing deep flowing eddy currents, as state variables. The simulation results are validated by comparison with two independent methods viz. Runge-Kutta simulation for a simplified system and a method based on modelling damper windings using conventional induction motor theory.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A two-level control scheme for the load frequency control of a multi-area power system utilizing certain possible beneficial aspects of interconnections is described in this paper. The problem is identified as the determination of the necessary equivalent perturbation on the control distribution matrix to provide the corrective control.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The development of algorithms, based on Haar functions, for extracting the desired frequency components from transient power-system relaying signals is presented. The applications of these algorithms to impedance detection in transmission line protection and to harmonic restraint in transformer differential protection are discussed. For transmission line protection, three modes of application of the Haar algorithms are described: a full-cycle window algorithm, an approximate full-cycle window algorithm, and a half-cycle window algorithm. For power transformer differential protection, the combined second and fifth harmonic magnitude of the differential current is compared with that of fundamental to arrive at a trip decision. The proposed line protection algorithms are evaluated, under different fault conditions, using realistic relaying signals obtained from transient analysis conducted on a model 400 kV, 3-phase system. The transformer differential protection algorithms are also evaluated using a variety of simulated inrush and internal fault signals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple multiple pulsewidth modulated (MPWM) ac chopper using power transistors for 3-¿ power control is discussed. 120° chopping period is used for main transistors so that the circuit can accommodate resistive and lagging or leading power factor loads. Only 1-¿ sensing is used for 3-¿ control. An alternate economical power and control schemes for 3-¿ MPWM ac choppers suitable only for resistive loads is also suggested. The experimental results for 12 choppings per cycle are given.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new technique for reducing the torque pulsations in a conventional current source inverter fed induction motor drive is presented. This does not attempt to improve the current waveforms, but modifies the airgap MMF directly. This is based on the use of a motor with two sets of balanced phase windings, with a 30 electrical degree phase difference between them, and each set being fed from a conventional current source inverter. The two inverters are further connected in series so that they can operate from the same current source. As a consequence of this arrangement, the voltage rating of the components of each inverter is reduced, along with reduced torque ripple. This scheme has been experimentally verified and compared with the performance of a conventional scheme.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes a method for the dynamic digital simulation of HVDC transmission systems. The method employs a novel modular converter representation during both normal and abnormal conditions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a general hardware scheme for testing protective relays using microprocessor based systems. The microprocessor simulates the relaying signals for test purpose and monitors the relay performance. Based on the proposed hardware, a teat procedure for directional overcurrent relays is presented in detail. Typical test results of various routine tests conducted on a commercial single phase directional over-current relay clearly demonstrate the efficacy of the proposed technique for conducting tests on commercial relays.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Schoeffler has derived continuously equivalent networks in the nodal-admittance domain. The letter derives a corresponding result in state space that combines the usefulness of Schoeffler's result and the power of the state-variable approach.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Special switching sequences can be employed in space-vector-based generation of pulsewidth-modulated (PWM) waveforms for voltage-source inverters. These sequences involve switching a phase twice, switching the second phase once, and clamping the third phase in a subcycle. Advanced bus-clamping PWM (ABCPWM) techniques have been proposed recently that employ such switching sequences. This letter studies the spectral properties of the waveforms produced by these PWM techniques. Further, analytical closed-form expressions are derived for the total rms harmonic distortion due to these techniques. It is shown that the ABCPWM techniques lead to lower distortion than conventional space vector PWM and discontinuous PWM at higher modulation indexes. The findings are validated on a 2.2-kW constant $V/f$ induction motor drive and also on a 100-kW motor drive.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective To perform spectral analysis of noise generated by equipments and activities in a level III neonatal intensive care unit (NICU) and measure the real time sequential hourly noise levels over a 15 day period. Methods Noise generated in the NICU by individual equipments and activities were recorded with a digital spectral sound analyzer to perform spectral analysis over 0.5–8 KHz. Sequential hourly noise level measurements in all the rooms of the NICU were done for 15 days using a digital sound pressure level meter. Independent sample t test and one way ANOVA were used to examine the statistical significance of the results. The study has a 90% power to detect at least 4 dB differences from the recommended maximum of 50 dB with 95 % confidence. Results The mean noise levels in the ventilator room and stable room were 19.99 dB (A) sound pressure level (SPL) and 11.81 dB (A) SPL higher than the maximum recommended of 50 dB (A) respectively (p < 0.001). The equipments generated 19.11 dB SPL higher than the recommended norms in 1–8 KHz spectrum. The activities generated 21.49 dB SPL higher than the recommended norms in 1–8 KHz spectrum (p< 0.001). The ventilator and nebulisers produced excess noise of 8.5 dB SPL at the 0.5 KHz spectrum.Conclusion Noise level in the NICU is unacceptably high. Spectral analysis of equipment and activity noise have shown noise predominantly in the 1–8 KHz spectrum. These levels warrant immediate implementation of noise reduction protocols as a standard of care in the NICU.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper proposes a control method that can balance the input currents of the three-phase three-wire boost rectifier under unbalanced input voltage condition. The control objective is to operate the rectifier in the high-power-factor mode under balanced input voltage condition but to give overriding priority to the current balance function in case of unbalance in the input voltage. The control structure has been divided into two major functional blocks. The inner loop current-mode controller implements resistor emulation to achieve high-power-factor operation on each of the two orthogonal axes of the stationary reference frame. The outer control loop performs magnitude scaling and phase-shifting operations on current of one of the axes to make it balanced with the current on the other axis. The coefficients of scaling and shifting functions are determined by two closed-loop prportional-integral (PI) controllers that impose the conditions of input current balance as PI references. The control algorithm is simple and high performing. It does not require input voltage sensing and transformation of the control variables into a rotating reference frame. The simulation results on a MATLAB-SIMULINK platform validate the proposed control strategy. In implementation Texas Instrument's digital signal processor TMS320F24OF is used as the digital controller. The control algorithm for high-power-factor operation is tested on a prototype boost rectifier under nominal and unbalanced input voltage conditions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple, low-cost, constant frequency, analog controller is proposed for the front-end half-bridge rectifier of a single-phase transformerless UPS system to maintain near unity power factor at the input and zero dc-offset voltage at the output. The controller generates the required gating pulses by comparing the input current with a periodic, bipolar, linear carrier without sensing the input voltage. Two voltage controllers and a single integrator with reset are used to generate the required carrier. All the necessary control operations can be performed without using any PLL, multiplier and/or divider. The controller can be fabricated as a single integrated circuit. The control concept is validated through simulation and also experimentally on an 800W half-bridge rectifier. Experimental results are presented for ac-dc application, and also for ac-dc-ac UPS application with both sinusoidal and nonlinear loads. The simulation and experimental results agree well.