305 resultados para Gas Permeable Contact Lems
Resumo:
Based on the an earlier CFD analysis of the performance of the gas-dynamically controlled laser cavity [1]it was found that there is possibility of optimizing the geometry of the diffuser that can bring about reductions in both size and cost of the system by examining the critical dimensional requirements of the diffuser. Consequently,an extensive CFD analysis has been carried out for a range of diffuser configurations by simulating the supersonic flow through the arrangement including the laser cavity driven by a bank of converging – diverging nozzles and the diffuser. The numerical investigations with 3D-RANS code are carried out to capture the flow patterns through diffusers past the cavity that has multiple supersonic jet interactions with shocks leading to complex flow pattern. Varying length of the diffuser plates is made to be the basic parameter of the study. The analysis reveals that the pressure recovery pattern during the flow through the diffuser from the simulation, being critical for the performance of the laser device shows its dependence on the diffuser length is weaker beyond a critical lower limit and this evaluation of this limit would provide a design guideline for a more efficient system configuration.The observation based on the parametric study shows that the pressure recovery transients in the near vicinity of the cavity is not affected for the reduction in the length of the diffuser plates up to its 10% of the initial size, indicating the design in the first configuration that was tested experimentally has a large factor of margin. The flow stability in the laser cavity is found to be unaffected since a strong and stable shock is located at the leading edge of the diffuser plates while the downstream shock and flow patterns are changed, as one would expect. Results of the study for the different lengths of diffusers in the range of 10% to its full length are presented, keeping the experimentally tested configuration used in the earlier study [1] as the reference length. The conclusions drawn from the analysis is found to be of significance since it provides new design considerations based on the understanding of the intricacies of the flow, allowing for a hardware optimization that can lead to substantial size reduction of the device with no loss of performance.
Resumo:
This paper reports an experimental investigation of low Weber number water drops impacting onto solid surfaces exhibiting anisotropic wetting. The wetting anisotropy is created by patterning the solid surfaces with unidirectional parallel grooves. Temporal measurements of impacting drop parameters such as drop base contact diameter, apparent contact angle of drop, and drop height at the center are obtained from high-speed video recordings of drop impacts. The study shows that the impact of low Weber number water drops on the grooved surface exhibits beating phenomenon in the temporal variations of the dynamic contact angle anisotropy and drop height at the center of the impacting drop. It is observed that the beating phenomenon of impacting drop parameters is caused by the frequency difference between the dynamic contact angle oscillations of impacting drop liquid oriented perpendicular and parallel to the direction of grooves on the grooved surface. The primary trigger for the phenomenon is the existence of non-axisymmetric drop flow on the grooved surface featuring pinned and free motions of drop liquid in the directions perpendicular and parallel to the grooves, respectively. The beat frequency is almost independent of the impact drop Weber number. Further experimental measurements with solid surfaces of different groove textures show that the grooved surface with larger wetting anisotropy may be expected to show a dominant beating phenomenon. The phenomenon is gradually damped out with time and is fully unrecognizable at higher drop impact Weber numbers. (C) 2011 Elsevier B.V. All rights reserved.