434 resultados para PLIC method


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe here a novel method of generating large volumetric heating in a liquid. The method uses the principle of ohmic heating of the liquid, rendered electrically conducting by suitable additives if necessary. Electrolysis is prevented by the use of high frequency alternating voltage and chemically treated electrodes. The technique is demonstrated by producing substantial heating in an initially neutral jet of water. Simple flow visualisation studies, made by adding dye to the jet, show marked changes in the growth and development of the jet with heat addition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A study has been carried out on the non-specific interference due to serum in the avidin biotin micro-ELISA for monkey chorionic gonadotropin. Results suggest that it is not due to any proteolytic activity in the serum, but immunoglobulin or associated factors interfering at the level of antigen-antibody interaction. This interference was eliminated by heating samples at 60°C for 30 min.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel approach for measurement of small rotation angles using imaging method is proposed and demonstrated. A plane mirror placed on a precision rotating table is used for imaging the newly designed composite coded pattern. The imaged patterns are captured with the help of a CCD camera. The angular rotation of the plane mirror is determined from a pair of the images of the pattern, captured once before and once after affecting the tilt of the mirror. Both simulation and experimental results suggest that the proposed approach not only retains the advantages of the original imaging method but also contributes significantly to the enhancement of its measuring range (+/- 4.13 degrees with accuracy of the order of 1 arcsec).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using solid oxide galvanic cells of the type: MnO + Gd2O3 + GdMnO3/O-2/Ni + NiO and Mn3O4 + GdMnO3 + GdMn2O5/O-2/air the equilibrium oxygen pressure for the following reactions :MnO + 1/2Gd(2)O(3) + 1/4O(2) = GdMnO3 1/3Mn(3)O(4) + GdMnO3 + 1/3O(2) = GdMn2O5 was determined in the temperature range from 1073 to 1450 K. From the determined equilibrium oxygen partial pressure the corresponding G i b b s free energy change for these reactions was derived: Delta G(f,GdMnO3)(0) (+/- 425J) 132721(+/ - 2240) +51.91(+/ - 0.81)T Delta G(f,GdMn2O5)(0)(+/- 670J) 121858(+/ - 6176) + 79.52(+/ - 4.83)T From these data, standard G i b b s energies, enthalpies and entropies of formation of GdMnO3 and GdMn2O5 from component oxides and from the elements are derived. Thermodynamic data tables for the two ternary phases are compiled from 298.15 to 1400 K.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In five-membered aromatic heterocyclic ring systems, a relation between the ratio of the distance between the two α to the two β protons and the covalent radii of the heteroatom is given. It is found that a similar relation is valid for the van der Waals radii also.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ZnO (core)/graphitic (shell) nanowires were successfully fabricated by a one-step method. Morphology of the as-grown nanowires was studied in detail by scanning electron microscopy, transmission electron microscopy (TEM), and energy dispersive X-ray analysis (EDS). High resolution TEM micrographs and selected area electron diffraction patterns reveal the core/shell morphology of the nanowires that grew along the c-axis of ZnO. EDS study of the nanowires confirms that there are no impurities within the detectable limit. Superconducting quantum interference device magnetometer measurements show room temperature ferromagnetic ordering in these core/shell nanowires. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thermal power stations use pulverized coal as fuel, producing enormous quantities of ash as a by-product of combustion. Currently, with very low utilization of the ash produced, the ash deposits at the thermal power stations are increasing rapidly. The disposal problem is expected to become alarming due to the limited space available for ash disposal near most thermal power stations. Among the various applications available for the use of fly ash, geotechnical application offers opportunity for its bulk utilization. However, the possibility of ground and surface water contamination due to the leaching of toxic elements present in the fly ash needs to be addressed. This paper describes a study carried out on two Indian fly ashes. It is found that pH is the controlling factor in the leaching behavior of fly ashes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The need for high purity materials for the growth of epitaxial layers of GaAs and the limitations of present source materials are discussed. A for purifying bulk quantitites of GaAs using chemical vapour transport is presented. GaAs is contained in a silica capsule which has a small orifice allow movement of gas between inside and outside. The capsule is contained in a heated tube and hydrogen chloride is used as the transporting agent. Growth rates of 0.1 g/h have been obtained and evidence for the purification is presented along with a discussion of the principles involved. The potentialities of the method for both purification and for the growth of single crystal substrate material are stressed.--AA

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A modified linear prediction (MLP) method is proposed in which the reference sensor is optimally located on the extended line of the array. The criterion of optimality is the minimization of the prediction error power, where the prediction error is defined as the difference between the reference sensor and the weighted array outputs. It is shown that the L2-norm of the least-squares array weights attains a minimum value for the optimum spacing of the reference sensor, subject to some soft constraint on signal-to-noise ratio (SNR). How this minimum norm property can be used for finding the optimum spacing of the reference sensor is described. The performance of the MLP method is studied and compared with that of the linear prediction (LP) method using resolution, detection bias, and variance as the performance measures. The study reveals that the MLP method performs much better than the LP technique.