143 resultados para EARTH ATMOSPHERE
Resumo:
Rechargeable lithium batteries have ushered the wireless revolution over last two decades and are now matured to enable green automobiles. However, the growing concern on scarcity and large-scale applications of lithium resources have steered effort to realize sustainable sodium-ion batteries, Na and Fe being abundant and low-cost charge carrier and redox centre, respectively. However, their performance is limited owing to low operating voltage and sluggish kinetics. Here we report a hitherto-unknown material with entirely new composition and structure with the first alluaudite-type sulphate framework, Na2Fe2(SO4)(3), registering the highest-ever Fe3+/ Fe2+ redox potential at 3.8V (versus Na, and hence 4.1V versus Li) along with fast rate kinetics. Rare-metal-free Na-ion rechargeable battery system compatible with the present Li-ion battery is now in realistic scope without sacrificing high energy density and high power, and paves way for discovery of new earth-abundant sustainable cathodes for large-scale batteries.
Resumo:
Systematic monitoring of subsurface hydrogeochemistry has been carried out for a period of one year in a humid tropical region along the Nethravati-Gurupur River. The major ion and stable isotope (delta O-18 and delta H-2) compositions are used to understand the hydrogeochemistry of groundwater and its interaction with surface water. In the study, it is observed that intense weathering of source rocks is the major source of chemical elements to the surface and subsurface waters. In addition, agricultural activities and atmospheric contributions also control the major ion chemistry of water in the study area. There is a clear seasonality in the groundwater chemistry, which is related to the recharge and discharge of the hydrological system. On a temporal scale, there is a decrease in major cation concentrations during the monsoon which is a result of dilution of sources from the weathering of rock minerals, and an increase in anion concentrations which is contributed by the atmosphere, accompanied by an increase in water level during the monsoon. The stable isotope composition indicates that groundwater in the basin is of meteoric origin and recharged directly from the local precipitation during the monsoonal season. Soon after the monsoon, groundwater and surface water mix in the subsurface region. The groundwater feeds the surface water during the lean river flow season.
Resumo:
Concentration of greenhouse gases (GHG) in the atmosphere has been increasing rapidly during the last century due to ever increasing anthropogenic activities resulting in significant increases in the temperature of the Earth causing global warming. Major sources of GHG are forests (due to human induced land cover changes leading to deforestation), power generation (burning of fossil fuels), transportation (burning fossil fuel), agriculture (livestock, farming, rice cultivation and burning of crop residues), water bodies (wetlands), industry and urban activities (building, construction, transport, solid and liquid waste). Aggregation of GHG (CO2 and non-CO2 gases), in terms of Carbon dioxide equivalent (CO(2)e), indicate the GHG footprint. GHG footprint is thus a measure of the impact of human activities on the environment in terms of the amount of greenhouse gases produced. This study focuses on accounting of the amount of three important greenhouses gases namely carbon dioxide (CO2), methane (CH4) and nitrous oxide (N2O) and thereby developing GHG footprint of the major cities in India. National GHG inventories have been used for quantification of sector-wise greenhouse gas emissions. Country specific emission factors are used where all the emission factors are available. Default emission factors from IPCC guidelines are used when there are no country specific emission factors. Emission of each greenhouse gas is estimated by multiplying fuel consumption by the corresponding emission factor. The current study estimates GHG footprint or GHG emissions (in terms of CO2 equivalent) for Indian major cities and explores the linkages with the population and GDP. GHG footprint (Aggregation of Carbon dioxide equivalent emissions of GHG's) of Delhi, Greater Mumbai, Kolkata, Chennai, Greater Bangalore, Hyderabad and Ahmedabad are found to be 38,633.2 Gg, 22,783.08 Gg, 14,812.10 Gg, 22,090.55 Gg, 19,796.5 Gg, 13,734.59 Gg and 91,24.45 Gg CO2 eq., respectively. The major contributors sectors are transportation sector (contributing 32%, 17.4%, 13.3%, 19.5%, 43.5%, 56.86% and 25%), domestic sector (contributing 30.26%, 37.2%, 42.78%, 39%, 21.6%, 17.05% and 27.9%) and industrial sector (contributing 7.9%, 7.9%, 17.66%, 20.25%, 1231%, 11.38% and 22.41%) of the total emissions in Delhi, Greater Mumbai, Kolkata, Chennai, Greater Bangalore, Hyderabad and Ahmedabad, respectively. Chennai emits 4.79 t of CO2 equivalent emissions per capita, the highest among all the cities followed by Kolkata which emits 3.29 t of CO2 equivalent emissions per capita. Also Chennai emits the highest CO2 equivalent emissions per GDP (2.55 t CO2 eq./Lakh Rs.) followed by Greater Bangalore which emits 2.18 t CO2 eq./Lakh Rs. (C) 2015 Elsevier Ltd. All rights reserved.
Resumo:
The use of pit-toilets has severely contaminated the groundwater with nitrate ions in Mulbagal town, Karnataka, India. This paper examines the potential of nitrate ions in the pit-toilet effluents to transform to N2O and to escape to atmosphere from 16 wards of Mulbagal town. Anaerobic conditions prevailing in the pit-toilet convert 25 % of the available N to ammonium ions. Only 3-33 % of ammonium ions transform to nitrate ions in the pit-toilet and escape with the effluent. During migration to aquifer, only 4.5 % of available nitrate concentration in the effluent transforms to N-2 and N2O gases in the 1.5-m-thick saturated zone underlying the pit-toilet; 36-55 % of the gases comprise N2O and the remainder of N-2. Further only 18 % of N2O formed escapes to atmosphere, while the remainder is retained in soil solution. Calculations show that 9.88 x 10(13) molecules of N2O/cm(2) would be cumulatively released from 16 wards of Mulbagal town, over an area of 4.9 km(2).
Resumo:
Recent studies, over regions influenced by biomass burning aerosol, have shown that it is possible to define a critical cloud fraction' (CCF) at which the aerosol direct radiative forcing switch from a cooling to a warming effect. Using 4 years of multi-satellite data analysis, we show that CCF varies with aerosol composition and changed from 0.28 to 0.13 from postmonsoon to winter as a result of shift from less absorbing to moderately absorbing aerosol. Our results indicate that we can estimate aerosol absorption from space using independently measured top of the atmosphere (TOA) fluxes Cloud Aerosol Lidar with Orthogonal Polarization-Moderate resolution Imaging Spectroradiometer-Clouds and the Earth's Radiant Energy System (CALIPSO-MODIS-CERES)] combined algorithms for example.
Resumo:
We report molecular dynamics (MD) simulations to explore the influence of a counterion on the structure and dynamics of cationic and anionic solvation shells for various ions in methanol at 298 K. We show that the variation in ionic size of either the cation or the anion in an ion pair influences the solvation structure of the other ion as well as the diffusivity in an electrolyte solution of methanol. The extent of ionic association between the cation and its counteranion of different ionic sizes has been investigated by analyzing the radial distribution functions (RDFs) and the orientation of methanol molecules in the first solvation shell (FSS) of ions. It is shown that the methanol in the FSS of the anion as well the cation exhibit quite different radial and orientational structures as compared to methanol which lie in the FSS of either the anion or the cation but not both. We find that the coordination number (CN) of F-, Cr-, and I- ions decreases with increasing size of the anion which is contrary to the trend reported for the anions in H2O. The mean residence time (MRT) of methanol molecules in the FSS of ions has been calculated using the stable states picture (SSP) approach. It is seen that the ion-counterion interaction has a considerable influence on the MRT of methanol molecules in the FSS of ions. We also discuss the stability order of the ion-counterion using the potentials of mean force (PMFs) for ion pairs with ions of different sizes. The PMF plots reveal that the Li+-F- pair (small-small) is highly stable and the Li+-I- pair is least stable (small-large) in electrolyte solutions.
Resumo:
The link between atmospheric CO2 level and ventilation state of the deep ocean is poorly understood due to the lack of coherent observations on the partitioning of carbon between atmosphere and ocean. In this Southern Ocean study, we have classified the Southern Ocean into different zones based on its hydrological features and have binned the variability in latitudinal air-CO2 concentration and its isotopic ratios. Together with air-CO2, we analysed the surface water for the isotopic ratios in dissolved inorganic carbon (DIC). Using the binary mixing approach on the isotopic ratio of atmospheric CO2 and its concentration, we identified the delta C-13 value of source CO2. The isotopic composition of source CO2 was around -9.22 +/- 0.26 parts per thousand for the year 2011 and 2012, while a composition of -13.49 +/- 4.07 parts per thousand was registered for the year 2013. We used the delta C-13 of DIC to predict the CO2 composition in air under equilibrium and compared our estimates with actual observations. We suggest that the degeneration of the DIC in presence of warm water in the region was the factor responsible for adding the CO2 to the atmosphere above. The place of observation coincides with the zone of high wind speed which promotes the process of CO2 exsolution from sea water. (C) 2015 Elsevier Ltd. All rights reserved.
Resumo:
Low-power electronic devices used in digital telecom exchanges are vulnerable to surge voltages and currents primarily originating from natural lightning or due to the direct interactions between electric power and telecommunication lines, etc., causing the earth/ground potential rise, neutral potential rise, and faults in the system. The fault currents may flow directly to telecom lines or through the equipment to the customer's premises, causing adequate damage to the equipment and personnel safety. In wireline applications, analog or digital, central office, exchanges, and subscriber sides have to be protected. Decisive protection and protective methods have to be employed for proper functioning of the equipment under overvoltage/overcurrent conditions. Current investigation reports some interesting results obtained on the recently developed high-voltage high-current protection cards used in digital telecom exchanges. The performances of protection cards both for the ring wave and hybrid wave surges are evaluated and presented. The surge generators required for the investigation are developed and fabricated in house as per the relevant telecom standards.