137 resultados para Assortative matching


Relevância:

10.00% 10.00%

Publicador:

Resumo:

A rainbow matching of an edge-colored graph G is a matching in which no two edges have the same color. There have been several studies regarding the maximum size of a rainbow matching in a properly edge-colored graph G in terms of its minimum degree 3(G). Wang (2011) asked whether there exists a function f such that a properly edge-colored graph G with at least f (delta(G)) vertices is guaranteed to contain a rainbow matching of size delta(G). This was answered in the affirmative later: the best currently known function Lo and Tan (2014) is f(k) = 4k - 4, for k >= 4 and f (k) = 4k - 3, for k <= 3. Afterwards, the research was focused on finding lower bounds for the size of maximum rainbow matchings in properly edge-colored graphs with fewer than 4 delta(G) - 4 vertices. Strong edge-coloring of a graph G is a restriction of proper edge-coloring where every color class is required to be an induced matching, instead of just being a matching. In this paper, we give lower bounds for the size of a maximum rainbow matching in a strongly edge-colored graph Gin terms of delta(G). We show that for a strongly edge-colored graph G, if |V(G)| >= 2 |3 delta(G)/4|, then G has a rainbow matching of size |3 delta(G)/4|, and if |V(G)| < 2 |3 delta(G)/4|, then G has a rainbow matching of size |V(G)|/2] In addition, we prove that if G is a strongly edge-colored graph that is triangle-free, then it contains a rainbow matching of size at least delta(G). (C) 2015 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Stimulus artifacts inhibit reliable acquisition of biological evoked potentials for several milliseconds if an electrode contact is utilized for both electrical stimulation and recording purposes. This hinders the measurement of evoked short-latency biological responses, which is otherwise elicited by stimulation in implantable prosthetic devices. We present an improved stimulus artifact suppression scheme using two electrode simultaneous stimulation and differential readout using high-gain amplifiers. Substantial reduction of artifact duration has been shown possible through the common-mode rejection property of an instrumentation amplifier for electrode interfaces. The performance of this method depends on good matching of electrode-electrolyte interface properties of the chosen electrode pair. A novel calibration algorithm has been developed that helps in artificial matching of impedance and thereby achieves the required performance in artifact suppression. Stimulus artifact duration has been reduced down to 50 mu s from the stimulation-cum-recording electrodes, which is similar to 6x improvement over the present state of the art. The system is characterized with emulated resistor-capacitor loads and a variety of in-vitro metal electrodes dipped in saline environment. The proposed method is going to be useful for closed-loop electrical stimulation and recording studies, such as bidirectional neural prosthesis of retina, cochlea, brain, and spinal cord.