29 resultados para Refrigerator cars.
Resumo:
A low cost 12 T pulsed magnet system has been integrated with a closed-cycle helium refrigerator. The copper solenoid is directly immersed in liquid nitrogen for reduced electrical resistance and more efficient heat transfer. This ensures a minimal delay of few minutes between pulses. The sample is mounted on the cold finger of the refrigerator and, along with the surrounding vacuum shroud, is inserted into the bore of the solenoid. When combined with software lock-in signal processing to reduce noise, quick but accurate measurements can be performed at temperatures 4 K-300 K up to 12 T. Quantum Hall effect data in a p-channel SiGe/Si heterostructure has been used to calibrate the instrument against a commercial superconducting magnet. Its versatility as a routine characterization tool is demonstrated bymeasuring parallel conduction in Si/SiGe modulation doped heterostructures.
Resumo:
A numerical modelling technique for predicting the detailed performance of a double-inlet type two-stage pulse tube refrigerator has been developed. The pressure variations in the compressor, pulse tube, and reservoir were derived, assuming the stroke volume variation of the compressor to be sinusoidal. The relationships of mass flowrates, volume flowrates, and temperature as a function of time and position were developed. The predicted refrigeration powers are calculated by considering the effect of void volumes and the phase shift between pressure and mass flowrate. These results are compared with the experimental results of a specific pulse tube refrigerator configuration and an existing theoretical model. The analysis shows that the theoretical predictions are in good agreement with each other.
Resumo:
Thermoacoustic refrigerator (TAR) converts acoustic waves into heat without any moving parts. The study presented here aims to optimize the parameters like frequency, stack position, stack length, and plate spacing involving in designing TAR using the Response Surface Methodology (RSM). A mathematical model is developed using the RSM based on the results obtained from DeltaEC software. For desired temperature difference of 40 K, optimized parameters suggested by the RSM are the frequency 254 Hz, stack position 0.108 m, stack length 0.08 m, and plate spacing 0.0005 m. The experiments were conducted with optimized parameters and simulations were performed using the Design Environment for Low-amplitude ThermoAcoustic Energy Conversion (DeltaEC) which showed similar results.
Resumo:
The thermoacoustic prime mover (TAPM) has gained considerable attention as a pressure wave generator to drive pulse tube refrigerator (PTR) due to no moving parts, reasonable efficiency, use of environmental friendly working fluids etc. To drive PTCs, lower frequencies (f) with larger pressure amplitudes (Delta P) are essential, which are affected by geometric and operating parameters of TAPM as well as working fluids. For driving PTRs, a twin standing wave TAPM is built and studied by using different working fluids such as helium, argon, nitrogen and their binary mixtures. Simulation results of DeltaEc are compared with experimental data wherever possible. DeltaEc predicts slightly increased resonance frequencies, but gives larger Delta P and lower temperature difference Delta T across stack. High mass number working fluid leads to lower frequency with larger Delta P, but higher Delta T. Studies indicate that the binary gas mixture of right composition with lower Delta T can be arrived at to drive TAPM of given geometry. (C) 2013 Elsevier Ltd and IIR. All rights reserved.
Resumo:
The objective of this study is to analyse the performance of thermoacoustic refrigerator (TAR) measured in terms of hot end temperature and temperature difference across refrigerator stack with two different spacing namely 0.4 mm and 0.8 mm and stack used in refrigerating section was made of low thermal conductivity materials namely Mylar sheet and photographic film & the experiments were carried out at 1 MPa pressure using helium as working fluid. High powered acoustic wave with frequency of 460 Hz and pressure amplitude of congruent to 0.07 MPa was obtained from twin thermoacoustic prime mover (TAPM) and this acoustic wave produced temperature difference of 16 degrees C across the Mylar sheet stack made of 0.4 mm spacing in refrigerator section. From this study, it has been inferred that twin TAPM can act as efficient drive for TAR. (C) 2013 Elsevier Ltd and IIR. All rights reserved.
Resumo:
As petrol prices are going up in developing countries in upcoming decades low cost electric cars will become more and more popular in developing world. One of the main deciding factors for success of electric cars specially in developing world in upcoming decades will be its cost. This paper shows a cost effective method to control the speed of low cost brushed D.C. motor by combining a IC 555 Timer with a High Boost Converter. The main purpose of using High Boost Converter since electric cars needs high voltage and current which a High Boost Converter can provide even with low battery supply.
Resumo:
The prime movers and refrigerators based on thermoacoustics have gained considerable importance toward practical applications in view of the absence of moving components, reasonable efficiency, use of environmental friendly working fluids, etc. Devices such as twin Standing Wave ThermoAcoustic Prime Mover (SWTAPM), Traveling Wave ThermoAcoustic Prime Mover (TWTAPM) and thermoacoustically driven Standing Wave ThermoAcoustic Refrigerator (SWTAR) have been studied by researchers. The numerical modeling and simulation play a vital role in their development. In our efforts to build the above thermoacoustic systems, we have carried out numerical analysis using the procedures of CFD on the above systems. The results of the analysis are compared with those of DeltaEC (freeware from LANL, USA) simulations and the experimental results wherever possible. For the CFD analysis commercial code Fluent 6.3.26 has been used along with the necessary boundary conditions for different working fluids at various average pressures. The results of simulation indicate that choice of the working fluid and the average pressure are critical to the performance of the above thermoacoustic devices. Also it is observed that the predictions through the CFD analysis are closer to the experimental results in most cases, compared to those of DeltaEC simulations. (C) 2015 Elsevier Ltd. All rights reserved.
Resumo:
This paper deals with a new form of nonlinear Raman spectroscopy called `ultrafast Raman loss spectroscopy (URLS)'. URLS is analogous to stimulated Raman spectroscopy (SRS) but is much more sensitive than SRS. The signals are background (noise) free unlike in coherent anti-Stokes Raman spectroscopy (CARS) and it provides natural fluorescence rejection, which is a major problem in Raman spectroscopy. In addition, being a self-phase matching process, the URLS experiment is much easier than CARS, which requires specific phase matching of the laser pulses. URLS is expected to be alternative if not competitive to CARS microscopy, which has become a popular technique in applications to materials, biology and medicine.
Resumo:
A two stage Gifford-McMahon cycle cryorefrigerator operating at 20 K is described. This refrigerator uses a very simple ‘spool valve’ and a modified indigenous compressor to compress helium gas. This cryorefrigerator reaches a lowest temperature of 15.5 K; it takes ≈ 50 min to reach 20 K and the cooling capacity is ≈ 2.5 W at 25 K. The cool-down characteristics and load characteristics are presented in graphical form. The effect of changing the operating pressure ratio and the second stage regenerator matrix size are also reported. Pressure-volume (P-V) diagrams obtained at various temperatures indicate that P-V losses form the major fraction of the total losses and this becomes more pronounced as the temperature is decreased. A heat balance analysis shows the relative magnitudes of various losses.
Resumo:
Exergy analysis of a Gifford-McMahon cycle refrigerator is presented. Exergy losses occurring in various components are considered and the exergy balance is shown in tabular form. It is observed that the major losses occur in the compressor and at the cold end.
Resumo:
High frequency, miniature, pulse tube cryocoolers are extensively used in space applications because of their simplicity. Parametric studies of inertance type pulse tube cooler are performed with different length-to-diameter ratios of the pulse tube with the help of the FLUENT (R) package. The local thermal non-equilibrium of the gas and the matrix is taken into account for the modeling of porous zones, in addition to the wall thickness of the components. Dynamic characteristics and the actual mechanism of energy transfer in pulse are examined with the help of the pulse tube wall time constant. The heat interaction between pulse tube wall and the oscillating gas, leading to surface heat pumping, is quantified. The axial heat conduction is found to reduce the performance of the pulse tube refrigerator. The thermal non-equilibrium predicts a higher cold heat exchanger temperature compared to thermal equilibrium. The pressure drop through the porous medium has a strong non-linear effect due to the dominating influence of Forchheimer term over that of the linear Darcy term at high operating frequencies. The phase angle relationships among the pressure, temperature and the mass flow rate in the porous zones are also important in determining the performance of pulse tuberefrigerator.