2 resultados para solution-based DNA extraction
em Illinois Digital Environment for Access to Learning and Scholarship Repository
Resumo:
Heterodera glycines, the soybean cyst nematode, is the major pathogen of Glycine max (soybean). Effective management of this pathogen is contingent on the use of resistant cultivars, thus screening for resistant cultivars is essential. The purpose of this research was to develop a method to assess infection of soybean roots by H. glycines with real-time quantitative Polymerase Chain Reaction (qPCR), a prelude to differentiation of resistance levels in soybean cultivars. Two experiments were conducted. In the first one, a consistent inoculation method was developed using to provide active second-stage juveniles (J2). Two-day-old soybean roots were infested with 0 and 1000 J2/mL. Twenty-four hours after infestation, the roots were surface sterilized and DNA was extracted with the DNA FastKit (MP Biomedicals, Santa Ana, CA)). For the qPCR assay, primer pair for single copy gene HgSNO, which codes for a protein involved in the production of vitamin B6, was selected for H. glycines DNA amplification within soybean roots. In the second experiment, compatible Lee 74, incompatible Peking and cultivars with different levels of resistance to H. glycines were inoculated with 0 and 1,000 J2/seedlings. Twenty-four hours post inoculation they were transplanted into pasteurized soil. Subsequently they were harvested at 1, 7, 10, 14 and 21 days post inoculation for DNA extraction. With the qPCR assay, the time needed to differentiate highly resistant cultivars from the rest was reduced. Quantification of H. glycines infection by traditional means (numbers of females produced in 30 days) is a time-consuming practice; the qPCR method can replace the traditional one and improve precision in determining infection levels.
Resumo:
A micro gas sensor has been developed by our group for the detection of organo-phosphate vapors using an aqueous oxime solution. The analyte diffuses from the high flow rate gas stream through a porous membrane to the low flow rate aqueous phase. It reacts with the oxime PBO (1-Phenyl-1,2,3,-butanetrione 2-oxime) to produce cyanide ions, which are then detected electrochemically from the change in solution potential. Previous work on this oxime based electrochemistry indicated that the optimal buffer pH for the aqueous solution was approximately 10. A basic environment is needed for the oxime anion to form and the detection reaction to take place. At this specific pH, the potential response of the sensor to an analyte (such as acetic anhydride) is maximized. However, sensor response slowly decreases as the aqueous oxime solution ages, by as much as 80% in first 24 hours. The decrease in sensor response is due to cyanide which is produced during the oxime degradation process, as evidenced by the cyanide selective electrode. Solid phase micro-extraction carried out on the oxime solution found several other possible degradation products, including acetic acid, N-hydroxy benzamide, benzoic acid, benzoyl cyanide, 1-Phenyl 1,3-butadione, 2-isonitrosoacetophenone and an imine derived from the oxime. It was concluded that degradation occurred through nucleophilic attack by a hydroxide or oxime anion to produce cyanide, as well as a nitrogen atom rearrangement similar to Beckmann rearrangement. The stability of the oxime in organic solvents is most likely due to the lack of water, and specifically hydroxide ions. The reaction between oxime and organo-phosphate to produce cyanide ions requires hydroxide ions, and therefore pure organic solvents are not compatible with the current micro-sensor electrochemistry. By combining a concentrated organic oxime solution with the basic aqueous buffer just prior to being used in the detection process, oxime degradation can be avoided while preserving the original electrochemical detection scheme. Based on beaker cell experiments with selective cyanide sensitive electrodes, ethanol was chosen as the best organic solvent due to its stabilizing effect on the oxime, minimal interference with the aqueous electrochemistry, and compatibility with the current microsensor material (PMMA). Further studies showed that ethanol had a small effect on micro-sensor performance by reducing the rate of cyanide production and decreasing the overall response time. To avoid incomplete mixing of the aqueous and organic solutions, they were pre-mixed externally at a 10:1 ratio, respectively. To adapt the microsensor design to allow for mixing to take place within the device, a small serpentine channel component was fabricated with the same dimensions and material as the original sensor. This allowed for seamless integration of the microsensor with the serpentine mixing channel. Mixing in the serpentine microchannel takes place via diffusion. Both detector potential response and diffusional mixing improve with increased liquid residence time, and thus decreased liquid flowrate. Micromixer performance was studies at a 10:1 aqueous buffer to organic solution flow rate ratio, for a total rate of 5.5 μL/min. It was found that the sensor response utilizing the integrated micromixer was nearly identical to the response when the solutions were premixed and fed at the same rate.